Biomechanical effect of different lumbar interspinous implants on flexibility and intradiscal pressure

被引:249
|
作者
Wilke, Hans-Joachim [1 ]
Drumm, J. [2 ]
Haeussler, K. [1 ]
Mack, C. [1 ]
Steudel, W. -I. [2 ]
Kettler, A. [1 ]
机构
[1] Univ Ulm, Inst Orthopaed Res & Biomech Director L Claes, D-89081 Ulm, Germany
[2] Saarland Univ Hosp, Dept Neurosurg, Homburg, Germany
关键词
lumbar spine; interspinous implant; biomechanics; flexibility; intradiscal pressure;
D O I
10.1007/s00586-008-0657-2
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Interspinous implants are used to treat lumbar spinal stenosis or facet joint arthritis. The aims of implanting interspinous devices are to unload the facet joints, restore foraminal height and provide stability especially in extension but still allow motion. The aim of this in vitro study was to compare four different interspinous implants-Colfex, Wallis, Diam and X-Stop-in terms of their three-dimensional flexibility and the intradiscal pressure. Twenty-four human lumbar spine specimens were divided into four equal groups and tested with pure moments in flexion/extension, lateral bending and axial rotation: (1) intact, (2) defect, (3) after implantation. Range of motion and the intradiscal pressure were determined.In each implant-group the defect caused an increase in range of motion by about 8% in lateral bending to 18% in axial rotation. Implantation had similar effects with all four implants. In extension, Coflex, Wallis, Diam, and X-Stop all overcompensated the instability caused by the defect and allowed about 50% of the range of motion of the intact state. In contrast, in flexion, lateral bending and axial rotation the values of the range of motion stayed about the values of the defect state. Similarly the intradiscal pressure after implantation was similar to that of the intact specimens in flexion, lateral bending and axial rotation but much smaller during extension. All tested interspinous implants had a similar effect on the flexibility: they strongly stabilized and reduced the intradiscal pressure in extension, but had almost no effect in flexion, lateral bending and axial rotation.
引用
收藏
页码:1049 / 1056
页数:8
相关论文
共 50 条
  • [41] Biomechanical Comparison of an Interspinous Device and a Rigid Stabilization on Lumbar Adjacent Segment Range of Motion
    Hartmann, F.
    Dietz, S. O.
    Kuhn, S.
    Hely, H.
    Rommens, P. M.
    Gercek, E.
    ACTA CHIRURGIAE ORTHOPAEDICAE ET TRAUMATOLOGIAE CECHOSLOVACA, 2011, 78 (05) : 404 - 409
  • [42] LOADS ON THE LUMBAR SPINE - VALIDATION OF A BIOMECHANICAL ANALYSIS BY MEASUREMENTS OF INTRADISCAL PRESSURES AND MYOELECTRIC SIGNALS
    SCHULTZ, A
    ANDERSSON, G
    ORTENGREN, R
    HADERSPECK, K
    NACHEMSON, A
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1982, 64 (05): : 713 - 720
  • [43] BIOMECHANICAL INVESTIGATION AND BONE-IMPLANT STRESS ANALYSIS OF A NOVEL LUMBAR INTERSPINOUS SPACER
    Parikh, Rachit
    Amanesh, Amanesh
    Kiapour, Ali
    Goel, Vijay K.
    Abjornson, Celeste
    PROCEEDINGS OF THE ASME SUMMER BIOENGINEERING CONFERENCE - 2009, PT A AND B, 2009, : 655 - 656
  • [44] Factors affecting intradiscal pressure measurement during in vitro biomechanical tests
    Tremblay, Jaelle
    Brailovski, Vladimir
    Mac-Thiong, Jean-Marc
    Petit, Yvan
    SCOLIOSIS AND SPINAL DISORDERS, 2015, 10
  • [45] Biomechanical study on the effect of cervical spine fusion on adjacent-level intradiscal pressure and segmental motion
    Eck, JC
    Humphreys, SC
    Lim, TH
    Jeong, ST
    Kim, JG
    Hodges, SD
    An, HS
    SPINE, 2002, 27 (22) : 2431 - 2434
  • [46] Lumbar spine stability after combined application of interspinous fastener and modified posterior lumbar interbody fusion: a biomechanical study
    Xiuchun Yu
    Lei Zhu
    Qing Su
    Archives of Orthopaedic and Trauma Surgery, 2014, 134 : 623 - 629
  • [47] INVIVO MEASUREMENTS OF INTRADISCAL PRESSURE - DISCOMETRY, A METHOD FOR THE DETERMINATION OF PRESSURE IN THE LOWER LUMBAR DISCS
    NACHEMSON, A
    MORRIS, JM
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1964, 46 (05): : 1077 - 1092
  • [48] TREATING LUMBAR DISC LESION BY PROLONGED CONTINUOUS REDUCTION OF INTRADISCAL PRESSURE
    HIRSCHBERG, GG
    TEXAS MEDICINE, 1974, 70 (12) : 58 - 68
  • [49] Lumbar spine stability after combined application of interspinous fastener and modified posterior lumbar interbody fusion: a biomechanical study
    Yu, Xiuchun
    Zhu, Lei
    Su, Qing
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2014, 134 (05) : 623 - 629
  • [50] Influence of varying muscle forces on lumbar intradiscal pressure: An in vitro study
    Wilke, HJ
    Wolf, S
    Claes, LE
    Arand, M
    Wiesend, A
    JOURNAL OF BIOMECHANICS, 1996, 29 (04) : 549 - 555