Biomechanical effect of different lumbar interspinous implants on flexibility and intradiscal pressure

被引:249
|
作者
Wilke, Hans-Joachim [1 ]
Drumm, J. [2 ]
Haeussler, K. [1 ]
Mack, C. [1 ]
Steudel, W. -I. [2 ]
Kettler, A. [1 ]
机构
[1] Univ Ulm, Inst Orthopaed Res & Biomech Director L Claes, D-89081 Ulm, Germany
[2] Saarland Univ Hosp, Dept Neurosurg, Homburg, Germany
关键词
lumbar spine; interspinous implant; biomechanics; flexibility; intradiscal pressure;
D O I
10.1007/s00586-008-0657-2
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Interspinous implants are used to treat lumbar spinal stenosis or facet joint arthritis. The aims of implanting interspinous devices are to unload the facet joints, restore foraminal height and provide stability especially in extension but still allow motion. The aim of this in vitro study was to compare four different interspinous implants-Colfex, Wallis, Diam and X-Stop-in terms of their three-dimensional flexibility and the intradiscal pressure. Twenty-four human lumbar spine specimens were divided into four equal groups and tested with pure moments in flexion/extension, lateral bending and axial rotation: (1) intact, (2) defect, (3) after implantation. Range of motion and the intradiscal pressure were determined.In each implant-group the defect caused an increase in range of motion by about 8% in lateral bending to 18% in axial rotation. Implantation had similar effects with all four implants. In extension, Coflex, Wallis, Diam, and X-Stop all overcompensated the instability caused by the defect and allowed about 50% of the range of motion of the intact state. In contrast, in flexion, lateral bending and axial rotation the values of the range of motion stayed about the values of the defect state. Similarly the intradiscal pressure after implantation was similar to that of the intact specimens in flexion, lateral bending and axial rotation but much smaller during extension. All tested interspinous implants had a similar effect on the flexibility: they strongly stabilized and reduced the intradiscal pressure in extension, but had almost no effect in flexion, lateral bending and axial rotation.
引用
收藏
页码:1049 / 1056
页数:8
相关论文
共 50 条
  • [21] Biomechanical analysis of a new lumbar interspinous device with optimized topology
    Chen, Chen-Sheng
    Shih, Shih-Liang
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2018, 56 (08) : 1333 - 1341
  • [22] The Effects of Physiological Biomechanical Loading on Intradiscal Pressure and Annulus Stress in Lumbar Spine: A Finite Element Analysis
    Zahari, Siti Nurfaezah
    Latif, Mohd Juzaila Abd
    Rahim, Nor Raihanah Abdull
    Kadir, Mohammed Rafiq Abdul
    Kamarul, Tunku
    JOURNAL OF HEALTHCARE ENGINEERING, 2017, 2017
  • [23] Biomechanical effect of interspinous process distraction height after lumbar fixation surgery: An in vitro model
    Fu, Lin
    Ma, Jianxiong
    Lu, Bin
    Jia, Haobo
    Zhao, Jie
    Kuang, Mingjie
    Feng, Rui
    Xu, Liyan
    Bai, Haohao
    Sun, Lei
    Wang, Ying
    Ma, Xinlong
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2017, 237 (07) : 663 - 672
  • [24] Biomechanical comparison of different interspinous process devices in the treatment of lumbar spinal stenosis: a finite element analysis
    Zhengpeng Liu
    Shuyi Zhang
    Jia Li
    Hai Tang
    BMC Musculoskeletal Disorders, 23
  • [25] Retaining intradiscal pressure after annulotomy by different annular suture techniques, and their biomechanical evaluations
    Chiang, Yueh-Feng
    Chiang, Chang-Jung
    Yang, Chih-Hong
    Zhong, Zheng-Cheng
    Chen, Chen-Sheng
    Cheng, Cheng-Kung
    Tsuang, Yang-Hwei
    CLINICAL BIOMECHANICS, 2012, 27 (03) : 241 - 248
  • [26] Biomechanical comparison of different interspinous process devices in the treatment of lumbar spinal stenosis: a finite element analysis
    Liu, Zhengpeng
    Zhang, Shuyi
    Li, Jia
    Tang, Hai
    BMC MUSCULOSKELETAL DISORDERS, 2022, 23 (01)
  • [27] Measurement of intradiscal pressure after lumbar discectomy
    Shahadi, F.
    Luecke, M.
    Preuss, M.
    Huegens-Penzel, M.
    Nestler, U.
    ZENTRALBLATT FUR NEUROCHIRURGIE, 2008, 69 (02): : 87 - 89
  • [28] Biomechanical analysis of lumbar fusion with proximal interspinous process device implantation
    Shen, Hangkai
    Fogel, Guy R.
    Zhu, Jia
    Liao, Zhenhua
    Liu, Weiqiang
    INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING, 2021, 37 (08)
  • [29] The Influence of Distraction Force on the Intradiscal Pressure Gradient in the Bridged Lumbar Spine A Biomechanical Investigation Using a Calf Model
    Spiegl, Ulrich
    Paetzold, Robert
    Glasmacher, Stefan
    Stephan, Daniel
    Josten, Christoph
    Buehren, Volker
    Gonschorek, Oliver
    Augat, Peter
    SPINE, 2014, 39 (07) : E427 - E433
  • [30] Effect of Annular Defects on Intradiscal Pressures in the Lumbar Spine: An in Vitro Biomechanical Study of Diskectomy and Annular Repair
    Bostelmann, Richard
    Steiger, Hans-Jakob
    Cornelius, Jan Frederick
    JOURNAL OF NEUROLOGICAL SURGERY PART A-CENTRAL EUROPEAN NEUROSURGERY, 2017, 78 (01) : 46 - 52