Effect of an interspinous implant on loads in the lumbar spine

被引:7
|
作者
Rohlmann, A [1 ]
Zander, T [1 ]
Burra, NK [1 ]
Bergmann, G [1 ]
机构
[1] Charite Univ Med Berlin, Orthoped Hosp, Biomech Lab, D-12203 Berlin, Germany
来源
BIOMEDIZINISCHE TECHNIK | 2005年 / 50卷 / 10期
关键词
lumbar spine; finite element method; interspinous implant; biomechanics;
D O I
10.1515/BMT.2005.048
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Interspinous process implants are increasingly used to treat canal stenoses. Little information exists about the effects of implant height and stiffness on the biomechanical behavior of the lumbar spine. Therefore, a three-dimensional nonlinear finite element model of the osseoligamentous lumbar spine (L1 to L5) was created with a slightly degenerated disc at L3/L4. An interspinous implant was inserted at that segment. Implants with different heights and stiffnesses were studied. The model was loaded with the upper body weight and muscle forces to simulate walking and 25 degrees extension. Implant forces are influenced strongly by the height and negligibly by the elastic modulus of the implant. Intersegmental rotation at implant level is markedly reduced, while intradiscal pressure is slightly increased. Implant size and stiffness have only a minor effect on intradiscal pressure. The maximum von Mises stress in the vertebral arch is strongly increased by the implant.
引用
收藏
页码:343 / 347
页数:5
相关论文
共 50 条
  • [1] Interspinous implant aEuroInSWingA®aEuroe for the lumbar spine
    Pfeiffer, Michael
    OPERATIVE ORTHOPADIE UND TRAUMATOLOGIE, 2010, 22 (5-6): : 512 - 523
  • [2] The effects of an interspinous implant on the kinematics of the instrumented and adjacent levels in the lumbar spine
    Lindsey, DP
    Swanson, KE
    Fuchs, P
    Hsu, KY
    Zucherman, JF
    Yerby, SA
    SPINE, 2003, 28 (19) : 2192 - 2197
  • [3] Device related complications of the Coflex interspinous process implant for the lumbar spine
    Zang Lei
    Du Peng
    Hai Yong
    Su Qing-jun
    Lu Shi-bao
    Liu Tie
    CHINESE MEDICAL JOURNAL, 2013, 126 (13) : 2517 - 2522
  • [4] Device related complications of the Coflex interspinous process implant for the lumbar spine
    ZANG Lei
    DU Peng
    HAI Yong
    SU Qing-jun
    LU Shi-bao
    LIU Tie
    中华医学杂志(英文版), 2013, 126 (13) : 2517 - 2522
  • [5] Restoring lumbar spine stiffness using an interspinous implant in an ovine model of instability
    Szpalski, Marek
    Gunzburg, Robert
    Colloca, Christopher J.
    Kosmopoulos, Victor
    Hegazy, Mostafa Afifi
    Freeman, Brian J.C.
    Fabeck, Laurent
    Clinical Biomechanics, 2016, 33 : 85 - 91
  • [6] Restoring lumbar spine stiffness using an interspinous implant in an ovine model of instability
    Szpalski, Marek
    Gunzburg, Robert
    Colloca, Christopher J.
    Kosmopoulos, Victor
    Hegazy, Mostafa Afifi
    Freeman, Brian J. C.
    Fabeck, Laurent
    CLINICAL BIOMECHANICS, 2016, 33 : 85 - 91
  • [7] Effect of a novel interspinous implant on lumbar spinal range of motion
    Gunzburg, Robert
    Szpalski, Marek
    Callary, Stuart A.
    Colloca, Christopher J.
    Kosmopoulos, Victor
    Harrison, Deed
    Moore, Robert J.
    EUROPEAN SPINE JOURNAL, 2009, 18 (05) : 696 - 703
  • [8] Interspinous process devices in the lumbar spine
    Bono, Christopher M.
    Vaccaro, Alexander R.
    JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2007, 20 (03): : 255 - 261
  • [9] Effect of a novel interspinous implant on lumbar spinal range of motion
    Robert Gunzburg
    Marek Szpalski
    Stuart A. Callary
    Christopher J. Colloca
    Victor Kosmopoulos
    Deed Harrison
    Robert J. Moore
    European Spine Journal, 2009, 18 : 696 - 703
  • [10] Interspinous and spinolaminar synthetic vertebropexy of the lumbar spine
    Calek, Anna-Katharina
    Altorfer, Franziska
    Fasser, Marie-Rosa
    Widmer, Jonas
    Farshad, Mazda
    EUROPEAN SPINE JOURNAL, 2023, 32 (09) : 3183 - 3191