Biomechanical effect of different lumbar interspinous implants on flexibility and intradiscal pressure

被引:249
|
作者
Wilke, Hans-Joachim [1 ]
Drumm, J. [2 ]
Haeussler, K. [1 ]
Mack, C. [1 ]
Steudel, W. -I. [2 ]
Kettler, A. [1 ]
机构
[1] Univ Ulm, Inst Orthopaed Res & Biomech Director L Claes, D-89081 Ulm, Germany
[2] Saarland Univ Hosp, Dept Neurosurg, Homburg, Germany
关键词
lumbar spine; interspinous implant; biomechanics; flexibility; intradiscal pressure;
D O I
10.1007/s00586-008-0657-2
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Interspinous implants are used to treat lumbar spinal stenosis or facet joint arthritis. The aims of implanting interspinous devices are to unload the facet joints, restore foraminal height and provide stability especially in extension but still allow motion. The aim of this in vitro study was to compare four different interspinous implants-Colfex, Wallis, Diam and X-Stop-in terms of their three-dimensional flexibility and the intradiscal pressure. Twenty-four human lumbar spine specimens were divided into four equal groups and tested with pure moments in flexion/extension, lateral bending and axial rotation: (1) intact, (2) defect, (3) after implantation. Range of motion and the intradiscal pressure were determined.In each implant-group the defect caused an increase in range of motion by about 8% in lateral bending to 18% in axial rotation. Implantation had similar effects with all four implants. In extension, Coflex, Wallis, Diam, and X-Stop all overcompensated the instability caused by the defect and allowed about 50% of the range of motion of the intact state. In contrast, in flexion, lateral bending and axial rotation the values of the range of motion stayed about the values of the defect state. Similarly the intradiscal pressure after implantation was similar to that of the intact specimens in flexion, lateral bending and axial rotation but much smaller during extension. All tested interspinous implants had a similar effect on the flexibility: they strongly stabilized and reduced the intradiscal pressure in extension, but had almost no effect in flexion, lateral bending and axial rotation.
引用
收藏
页码:1049 / 1056
页数:8
相关论文
共 50 条
  • [1] Biomechanical effect of different lumbar interspinous implants on flexibility and intradiscal pressure
    Hans-Joachim Wilke
    J. Drumm
    K. Häussler
    C. Mack
    W. -I. Steudel
    A. Kettler
    European Spine Journal, 2008, 17 : 1049 - 1056
  • [2] The effect of spinal destabilization and instrumentation on lumbar intradiscal pressure an in vitro biomechanical analysis
    Cunningham, BW
    Kotani, Y
    McNulty, PS
    Cappuccino, A
    McAfee, PC
    SPINE, 1997, 22 (22) : 2655 - 2663
  • [3] Biomechanical Analysis of Lumbar Interspinous Process Fixators and Design of Miniaturization and Advanced flexibility
    Park, Jung Hong
    Heo, Soon
    Son, Kwon
    Lee, Sung Jae
    TRANSACTIONS OF THE KOREAN SOCIETY OF MECHANICAL ENGINEERS A, 2006, 30 (12) : 1509 - 1517
  • [4] Biomechanical study on the effect of five different lumbar reconstruction techniques on adjacent-level intradiscal pressure and lamina strain
    Sudo, Hideki
    Oda, Itaru
    Abumi, Kuniyoshi
    Ito, Manabu
    Kotani, Yoshihisa
    Minami, Akio
    JOURNAL OF NEUROSURGERY-SPINE, 2006, 5 (02) : 150 - 155
  • [5] The effect of spinal instrumentation on lumbar intradiscal pressure
    Abe, E
    Nickel, T
    Buttermann, GR
    Lewis, JL
    Transfeldt, EE
    TOHOKU JOURNAL OF EXPERIMENTAL MEDICINE, 1999, 187 (03): : 237 - 247
  • [6] LUMBAR INTRADISCAL PRESSURE
    不详
    LANCET, 1960, 2 (JUL2): : 30 - 30
  • [7] Biomechanical effect of different interspinous devices on lumbar spinal range of motion under preload conditions
    Frank Hartmann
    Sven-Oliver Dietz
    Hans Hely
    Pol Maria Rommens
    Erol Gercek
    Archives of Orthopaedic and Trauma Surgery, 2011, 131 : 917 - 926
  • [8] Biomechanical effect of different interspinous devices on lumbar spinal range of motion under preload conditions
    Hartmann, Frank
    Dietz, Sven-Oliver
    Hely, Hans
    Rommens, Pol Maria
    Gercek, Erol
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2011, 131 (07) : 917 - 926
  • [9] EFFECT OF FORWARD LEANING ON LUMBAR INTRADISCAL PRESSURE
    NACHEMSON, A
    ACTA ORTHOPAEDICA SCANDINAVICA, 1965, 35 (04): : 314 - +
  • [10] Biomechanical Effect of Hybrid Dynamic Stabilization Implant on the Segmental Motion and Intradiscal Pressure in Human Lumbar Spine
    Hsiao, Chih-Kun
    Tsai, Yi-Jung
    Yen, Cheng-Yo
    Li, Yi-Chen
    Hsiao, Hao-Yuan
    Tu, Yuan-Kun
    BIOENGINEERING-BASEL, 2023, 10 (01):