In Vitro Kinematic Analysis of Single Axis Radius Posterior-Substituting Total Knee Arthroplasty

被引:4
|
作者
Arauz, Paul [1 ]
Peng, Yun [1 ]
Castillo, Tiffany [1 ]
Klemt, Christian [1 ]
Kwon, Young-Min [1 ]
机构
[1] Harvard Med Sch, Massachusetts Gen Hosp, Dept Orthopaed Surg, Bioengn Lab, 55 Fruit St, Boston, MA 02114 USA
关键词
medial and lateral collateral ligaments; posterior-substituting total knee arthroplasty; kinematics; force; PATIENT SATISFACTION; COLLATERAL LIGAMENT; VIVO KINEMATICS; HIGH-FLEXION; CONTACT; LAXITY; GENDER;
D O I
10.1055/s-0040-1708039
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
This is an experimental study. As current posterior-substituting (PS) total knee arthroplasties have been reported to incompletely restore intrinsic joint biomechanics of the healthy knee, the recently designed single axis radius PS knee system was introduced to increase posterior femoral translation and promote ligament isometry. As there is a paucity of data available regarding its ability to replicate healthy knee biomechanics, this study aimed to assess joint and articular contact kinematics as well as ligament isometry of the contemporary single axis radius PS knee system. Implant kinematics were measured from 11 cadaveric knees using an in vitro robotic testing system. In addition, medial collateral ligament (MCL) and lateral collateral ligament (LCL) forces were quantified under simulated functional loads during knee flexion for the contemporary PS knee system. Posterior femoral translation between the intact knee and the single axis radius PS knee system differed significantly ( p <0.05) at 60, 90, and 120degrees of flexion. The LCL force at 60degrees (9.06<plus/minus>2.81N) was significantly lower ( p <0.05) than those at 30, 90, and 120degrees of flexion, while MCL forces did not differ significantly throughout the range of tested flexion angles. The results from this study suggest that although the contemporary single axis radius PS knee system has the potential to mimic the intact knee kinematics under muscle loading during flexion extension due to its design features, single axis radius PS knee system did not fully replicate posterior femoral translation and ligament isometry of the healthy knee during knee flexion.
引用
收藏
页码:1253 / 1259
页数:7
相关论文
共 50 条
  • [31] Kinematic alignment in total knee arthroplasty
    Weber, Patrick
    Gollwitzer, Hans
    OPERATIVE ORTHOPADIE UND TRAUMATOLOGIE, 2021, 33 (06): : 525 - 537
  • [32] Bicruciate Substituting Total Knee Arthroplasty Improves Stair Climbing Ability When Compared with Cruciate-Retain or Posterior Stabilizing Total Knee Arthroplasty
    Iriuchishima, Takanori
    Ryu, Keinosuke
    INDIAN JOURNAL OF ORTHOPAEDICS, 2019, 53 (05) : 641 - 645
  • [33] Posterior tilting of the tibial component decreases femoral rollback in posterior-substituting knee replacement: A computer simulation study
    Piazza, SJ
    Delp, SL
    Stulberg, SD
    Stern, SH
    JOURNAL OF ORTHOPAEDIC RESEARCH, 1998, 16 (02) : 264 - 270
  • [34] Bicruciate Substituting Total Knee Arthroplasty Improves Stair Climbing Ability When Compared with Cruciate-Retain or Posterior Stabilizing Total Knee Arthroplasty
    Takanori Iriuchishima
    Keinosuke Ryu
    Indian Journal of Orthopaedics, 2019, 53 : 641 - 645
  • [35] Posterior cruciate ligament-substituting total knee arthroplasty in young rheumatoid patients with advanced knee involvement
    Tang, WM
    Chiu, KY
    Ng, TP
    Yau, WP
    JOURNAL OF ARTHROPLASTY, 2004, 19 (01): : 49 - 55
  • [36] Tibiofemoral kinematic analysis of kneeling after total knee arthroplasty
    Incavo, SJ
    Mullins, ER
    Coughlin, KM
    Banks, S
    Banks, A
    Beynnon, BD
    JOURNAL OF ARTHROPLASTY, 2004, 19 (07): : 906 - 910
  • [37] Cruciate Substituting Implants in Primary Total Knee Arthroplasty
    Volkmar, Alexander J.
    Elrod, Robert
    Vickery, Justin W.
    Yang, Charlie C.
    Polkowski, Gregory G.
    Martin, J. Ryan
    ADVANCES IN ORTHOPEDICS, 2022, 2022
  • [38] Interactive effect of femoral posterior condylar offset and tibial posterior slope on knee flexion in posterior cruciate ligament-substituting total knee arthroplasty
    Han, Hyuk-Soo
    Kang, Seung-Baik
    KNEE, 2018, 25 (02): : 335 - 340
  • [39] In vivo kinematic analysis of posterior-stabilized total knee arthroplasty for the valgus knee operated by the gap-balancing technique
    Suzuki, Koji
    Hara, Noriyuki
    Mikami, Susumu
    Tomita, Tetsuya
    Iwamoto, Keiji
    Yamazaki, Takaharu
    Sugamoto, Kazuomi
    Matsuno, Shigeo
    KNEE, 2014, 21 (06): : 1124 - 1128
  • [40] Postoperative Patellar Height After Undergoing Total Knee Arthroplasty: Mechanical Axis Versus Kinematic Axis
    Elkadi, Seleem
    Krisanda, Emily
    Panish, Brian J.
    Donaldson, Stiles
    Schaefer, Eliana
    Hamzeh, Malaak
    Bovill, John
    Freed, Natasha
    Elkordy, Zachariah
    El Masry, Seif
    Cach, Gina
    Jacquez, Evan
    Argintar, Evan
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2022, 14 (04)