In Vitro Kinematic Analysis of Single Axis Radius Posterior-Substituting Total Knee Arthroplasty

被引:4
|
作者
Arauz, Paul [1 ]
Peng, Yun [1 ]
Castillo, Tiffany [1 ]
Klemt, Christian [1 ]
Kwon, Young-Min [1 ]
机构
[1] Harvard Med Sch, Massachusetts Gen Hosp, Dept Orthopaed Surg, Bioengn Lab, 55 Fruit St, Boston, MA 02114 USA
关键词
medial and lateral collateral ligaments; posterior-substituting total knee arthroplasty; kinematics; force; PATIENT SATISFACTION; COLLATERAL LIGAMENT; VIVO KINEMATICS; HIGH-FLEXION; CONTACT; LAXITY; GENDER;
D O I
10.1055/s-0040-1708039
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
This is an experimental study. As current posterior-substituting (PS) total knee arthroplasties have been reported to incompletely restore intrinsic joint biomechanics of the healthy knee, the recently designed single axis radius PS knee system was introduced to increase posterior femoral translation and promote ligament isometry. As there is a paucity of data available regarding its ability to replicate healthy knee biomechanics, this study aimed to assess joint and articular contact kinematics as well as ligament isometry of the contemporary single axis radius PS knee system. Implant kinematics were measured from 11 cadaveric knees using an in vitro robotic testing system. In addition, medial collateral ligament (MCL) and lateral collateral ligament (LCL) forces were quantified under simulated functional loads during knee flexion for the contemporary PS knee system. Posterior femoral translation between the intact knee and the single axis radius PS knee system differed significantly ( p <0.05) at 60, 90, and 120degrees of flexion. The LCL force at 60degrees (9.06<plus/minus>2.81N) was significantly lower ( p <0.05) than those at 30, 90, and 120degrees of flexion, while MCL forces did not differ significantly throughout the range of tested flexion angles. The results from this study suggest that although the contemporary single axis radius PS knee system has the potential to mimic the intact knee kinematics under muscle loading during flexion extension due to its design features, single axis radius PS knee system did not fully replicate posterior femoral translation and ligament isometry of the healthy knee during knee flexion.
引用
收藏
页码:1253 / 1259
页数:7
相关论文
共 50 条
  • [41] Measured Resection Techniques Do Not Align to the Cylindrical Axis in Kinematic Total Knee Arthroplasty
    Drynan, David
    Rasouli, Rabi Faisal
    Williams, James W. A.
    Balalla, Buddhika
    ARTHROPLASTY TODAY, 2021, 8 : 157 - 162
  • [42] POSTERIOR DISLOCATION OF TOTAL KNEE ARTHROPLASTY
    SHARKEY, PF
    HOZACK, WJ
    BOOTH, RE
    BALDERSTON, RA
    ROTHMAN, RH
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1992, (278) : 128 - 133
  • [43] Intraoperative kinematic analysis of posterior stabilized total knee arthroplasty with asymmetric helical post-cam design
    Morooka, Takatoshi
    Okuno, Makiko
    Seino, Daisuke
    Iseki, Takuya
    Fukunishi, Shigeo
    Kobashi, Syoji
    Yoshiya, Shinichi
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2019, 29 (03): : 675 - 681
  • [44] Long-term results of total knee arthroplasty with single-radius versus multi-radius posterior-stabilized prostheses
    Luo, Zhenyu
    Luo, Zeyu
    Wang, Haoyang
    Xiao, Qiang
    Pei, Fuxing
    Zhou, Zongke
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2019, 14 (1)
  • [45] Long-term results of total knee arthroplasty with single-radius versus multi-radius posterior-stabilized prostheses
    Zhenyu Luo
    Zeyu Luo
    Haoyang Wang
    Qiang Xiao
    Fuxing Pei
    Zongke Zhou
    Journal of Orthopaedic Surgery and Research, 14
  • [46] Intraoperative kinematic analysis of posterior stabilized total knee arthroplasty with asymmetric helical post-cam design
    Takatoshi Morooka
    Makiko Okuno
    Daisuke Seino
    Takuya Iseki
    Shigeo Fukunishi
    Syoji Kobashi
    Shinichi Yoshiya
    European Journal of Orthopaedic Surgery & Traumatology, 2019, 29 : 675 - 681
  • [47] Inverse Kinematic Alignment for Total Knee Arthroplasty
    de Grave, Philip Winnock
    Kellens, Jonas
    Luyckx, Thomas
    Tampere, Thomas
    Lacaze, Franck
    Claeys, Kurt
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2022, 108 (05)
  • [48] Mechanical and kinematic alignment in total knee arthroplasty
    Schiraldi, Marco
    Bonzanini, Giancarlo
    Chirillo, Danilo
    de Tullio, Vito
    ANNALS OF TRANSLATIONAL MEDICINE, 2016, 4 (07)
  • [49] Kinetic analysis of posterior ligament subsitute total knee arthroplasty
    Yu, C. -T.
    Chang, C. -C.
    Lee, P. -K.
    OSTEOPOROSIS INTERNATIONAL, 2006, 17 : S19 - S19
  • [50] How Does Laxity After Single Radius Total Knee Arthroplasty Compare With the Native Knee?
    Hunt, Nicola C.
    Ghosh, Kanishka M.
    Blain, Alasdair P.
    Athwal, Kiron K.
    Rushton, Steve P.
    Amis, Andrew A.
    Longstaff, Lee M.
    Deehan, David J.
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2014, 32 (09) : 1208 - 1213