In Vitro Kinematic Analysis of Single Axis Radius Posterior-Substituting Total Knee Arthroplasty

被引:4
|
作者
Arauz, Paul [1 ]
Peng, Yun [1 ]
Castillo, Tiffany [1 ]
Klemt, Christian [1 ]
Kwon, Young-Min [1 ]
机构
[1] Harvard Med Sch, Massachusetts Gen Hosp, Dept Orthopaed Surg, Bioengn Lab, 55 Fruit St, Boston, MA 02114 USA
关键词
medial and lateral collateral ligaments; posterior-substituting total knee arthroplasty; kinematics; force; PATIENT SATISFACTION; COLLATERAL LIGAMENT; VIVO KINEMATICS; HIGH-FLEXION; CONTACT; LAXITY; GENDER;
D O I
10.1055/s-0040-1708039
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
This is an experimental study. As current posterior-substituting (PS) total knee arthroplasties have been reported to incompletely restore intrinsic joint biomechanics of the healthy knee, the recently designed single axis radius PS knee system was introduced to increase posterior femoral translation and promote ligament isometry. As there is a paucity of data available regarding its ability to replicate healthy knee biomechanics, this study aimed to assess joint and articular contact kinematics as well as ligament isometry of the contemporary single axis radius PS knee system. Implant kinematics were measured from 11 cadaveric knees using an in vitro robotic testing system. In addition, medial collateral ligament (MCL) and lateral collateral ligament (LCL) forces were quantified under simulated functional loads during knee flexion for the contemporary PS knee system. Posterior femoral translation between the intact knee and the single axis radius PS knee system differed significantly ( p <0.05) at 60, 90, and 120degrees of flexion. The LCL force at 60degrees (9.06<plus/minus>2.81N) was significantly lower ( p <0.05) than those at 30, 90, and 120degrees of flexion, while MCL forces did not differ significantly throughout the range of tested flexion angles. The results from this study suggest that although the contemporary single axis radius PS knee system has the potential to mimic the intact knee kinematics under muscle loading during flexion extension due to its design features, single axis radius PS knee system did not fully replicate posterior femoral translation and ligament isometry of the healthy knee during knee flexion.
引用
收藏
页码:1253 / 1259
页数:7
相关论文
共 50 条
  • [21] BIOMECHANICAL EFFECTS OF KNEELING WITH POSTERIOR CRUCIATE RETAINING AND POSTERIOR CRUCIATE SUBSTITUTING TOTAL KNEE ARTHROPLASTY
    Hofer, Jason K.
    Gejo, Ryuichi
    McGarry, Michelle H.
    Lee, Thay Q.
    PROCEEDINGS OF THE 4TH FRONTIERS IN BIOMEDICAL DEVICES CONFERENCE AND EXPOSITION - 2009, 2009, : 27 - 28
  • [22] Contact Kinematic Differences Between Gap Balanced vs Measured Resection Techniques for Single Radius Posterior-Stabilized Total Knee Arthroplasty
    Teeter, Matthew G.
    Perry, Kevin I.
    Yuan, Xunhua
    Howard, James L.
    Lanting, Brent A.
    JOURNAL OF ARTHROPLASTY, 2017, 32 (06): : 1834 - 1838
  • [23] Analysis of gender differences with traditional posterior stabilized versus kinematic designs in total knee arthroplasty
    Julian Koettnitz
    Jara Tigges
    Filippo Migliorini
    Christian D. Peterlein
    Christian Götze
    Archives of Orthopaedic and Trauma Surgery, 2023, 143 : 7153 - 7158
  • [24] Analysis of gender differences with traditional posterior stabilized versus kinematic designs in total knee arthroplasty
    Koettnitz, Julian
    Tigges, Jara
    Migliorini, Filippo
    Peterlein, Christian D.
    Goetze, Christian
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2023, 143 (12) : 7153 - 7158
  • [25] Changes of posterior condylar offset results in midflexion instability in single-radius total knee arthroplasty
    Matziolis, Georg
    Brodt, Steffen
    Windisch, Christoph
    Roehner, Eric
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2017, 137 (05) : 713 - 717
  • [26] Changes of posterior condylar offset results in midflexion instability in single-radius total knee arthroplasty
    Georg Matziolis
    Steffen Brodt
    Christoph Windisch
    Eric Roehner
    Archives of Orthopaedic and Trauma Surgery, 2017, 137 : 713 - 717
  • [27] Long-term results of posterior cruciate-substituting total knee arthroplasty
    Kelly, MA
    Clarke, HA
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2002, (404) : 51 - 57
  • [28] Single radius versus multiple radius femoral prostheses in total knee arthroplasty: a meta-analysis
    Li, Mengyuan
    Deng, Zhantao
    Jiang, Hai
    Ma, Yuanchen
    Liao, Junxing
    Zheng, Qiujian
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2019, 12 (08): : 9508 - 9521
  • [29] The cruciate ligaments in total knee arthroplasty - A kinematic analysis of 2 total knee arthroplasties
    Stiehl, JB
    Komistek, RD
    Cloutier, JM
    Dennis, DA
    JOURNAL OF ARTHROPLASTY, 2000, 15 (05): : 545 - 550
  • [30] Kinematic alignment in total knee arthroplasty
    Nisar, Sohail
    Palan, Jeya
    Riviere, Charles
    Emerton, Mark
    Pandit, Hemant
    EFORT OPEN REVIEWS, 2020, 5 (07) : 380 - 390