Lead isotopic analysis of Antarctic snow by quadrupole ICP-MS using a total-consumption sample introduction system

被引:4
|
作者
Ardini, Francisco [1 ]
Bazzano, Andrea [1 ]
Grotti, Marco [1 ]
机构
[1] Univ Genoa, Dept Chem & Ind Chem, Via Dodecaneso 31, I-16146 Genoa, Italy
关键词
PLASMA-MASS SPECTROMETRY; DYNAMIC REACTION CELL; DOME-C; SHEATHING GAS; LAW DOME; DUST; METALS; EPICA; CORE; CLIMATE;
D O I
10.1039/c8ja00296g
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Measurement of lead isotope ratios in snow samples using inductively coupled plasma-dynamic reaction cell-mass spectrometry (ICP-DRC-MS) at a low sample consumption rate was thoroughly studied. Sample volumes were reduced from 20.0 to 0.200 mL by freeze-drying, and the pre-concentrates were efficiently introduced into the plasma source at 20 mu L min(-1) by using the heated torch-integrated sample introduction system (hTISIS). In addition, the DRC was pressurised with neon to improve the precision by collisional damping. Sensitivity was maximised by optimising the operating parameters of the sample introduction system (nebulizer/sheathing gas flow rate ratio), the reaction cell (rod offset and damping gas flow rate) and the signal measurement conditions. The developed method was then characterised in terms of the analytical working range, accuracy and uncertainty estimation. Under the optimal conditions, isotope ratios did not differ in the 0.1-20 mu g L-1 range. Internal precision, expressed as relative standard deviation, varied from 0.12 to 0.18% (c = 10 mu g L-1; n = 12), while the external precision was <0.1%. The potential influence of the pre-concentration procedure on the analytical data was carefully investigated in terms of blank contribution, recovery and isotopic fractionation. The lowest Pb concentration needed in the samples to limit the influence of the blanks within an experimental precision of 0.5% was 4.4 pg g(-1), and the recovery of five standard reference solutions with a Pb concentration of 100 ng L-1 was 90 +/- 5%, with no significant isotopic fractionation. The developed ICP-DRC-MS method was finally applied to a number of representative Antarctic snow samples previously characterised by multi-collector ICP-MS, obtaining a satisfactory agreement between the data provided by the two techniques and analytical results consistent with literature data on the glaciochemistry of Antarctic ice cores.
引用
收藏
页码:2124 / 2132
页数:9
相关论文
共 50 条
  • [31] Determination of cadmium in environmental and biological reference materials using isotope dilution analysis with a double focusing ICP-MS: a comparison with quadrupole ICP-MS
    Valles Mota, JP
    Encinar, JR
    de la Campa, MRF
    Alonso, JIG
    Sanz-Medel, A
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1999, 14 (09) : 1467 - 1473
  • [32] Overcome unexpected interferences and accelerate environmental analysis using triple quadrupole ICP-MS
    Surekar, Bhagyesh
    Kutscher, Daniel
    BRAZILIAN JOURNAL OF ANALYTICAL CHEMISTRY, 2021, 8 (32): : 231 - 236
  • [33] A method for increasing the precision of isotope ratio analysis on a Quadrupole ICP-MS based on measurements of lead and strontium
    Dronov, Michail
    Schram, Juergen
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2013, 28 (11) : 1796 - 1803
  • [34] A highly efficient sample introduction system for interfacing micro. uidic chips with ICP-MS
    Pearson, Gareth
    Greenway, Gillian
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2007, 22 (06) : 657 - 662
  • [35] A new demountable hydrofluoric acid resistant triple mode sample introduction system for ICP-AES and ICP-MS
    Asfaw, Alemayehu
    Wibetoe, Grethe
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2007, 22 (02) : 158 - 163
  • [36] A fully automated total metals and chromium speciation single platform introduction system for ICP-MS
    Quarles, C. Derrick, Jr.
    Szoltysik, Michael
    Sullivan, Patrick
    Reijnen, Maurice
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2019, 34 (02) : 284 - 291
  • [37] Particle Trajectory Simulation Facilitates the Development of an Efficient Sample Introduction System for Single-Particle ICP-MS Analysis
    Wang, Dingyi
    Zhang, Junhui
    Fan, Changjun
    Li, Xiaodong
    Liu, Lihong
    Yan, Xueting
    Li, Yingying
    He, Bin
    Yin, Yongguang
    Hu, Ligang
    Jiang, Guibin
    ANALYTICAL CHEMISTRY, 2025, 97 (03) : 1792 - 1798
  • [38] Development of new desolvating sample introduction system for precise isotopic analysis of Fe by multiple collector-ICP-MS
    Hirata, T
    Kohge, I
    BUNSEKI KAGAKU, 2005, 54 (05) : 347 - 354
  • [39] Trace metal analysis in petroleum products: Sample introduction evaluation in ICP-OES and comparison with an ICP-MS approach
    Lienemann, C. P.
    Dreyfus, S.
    Pecheyran, C.
    Donard, O. F. X.
    OIL & GAS SCIENCE AND TECHNOLOGY-REVUE D IFP ENERGIES NOUVELLES, 2007, 62 (01): : 69 - 77
  • [40] Single-particle/Cell Analysis by Highly Time-resolved ICP-MS Using a High-efficiency Sample Introduction System
    Myashita, Shin-ichi
    Fujii, Shin-ichiro
    Inagaki, Kazumi
    BUNSEKI KAGAKU, 2017, 66 (09) : 663 - 676