A new demountable hydrofluoric acid resistant triple mode sample introduction system for ICP-AES and ICP-MS

被引:24
|
作者
Asfaw, Alemayehu [1 ]
Wibetoe, Grethe [1 ]
机构
[1] Univ Oslo, Dept Chem, N-0315 Oslo, Norway
关键词
D O I
10.1039/b609531c
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new sample introduction system with a triple mode function was developed by modifying a commercially available cyclonic spray chamber and combining it with a commercial parallel path nebulizer. The system can be used for nebulization only, vapor generation (hydride or cold vapor) only and both together (dual mode). The introduction system is very practical in use, as it can be dismantled from the bottom side and all the inserts can be removed and cleaned easily after the end of analysis. Unlike another commercial multimode system, this new one is HF-resistant and can be used with all acids. The analytical performance of the new HF-resistant triple mode sample introduction system (HFR-TMSIS) was studied by coupling it with ICP-AES and ICP-MS and comparing the performance with the conventional single mode HF-resistant sample introduction systems: i.e. a V-groove nebulizer with Sturman-Masters spray chamber for ICPAES and cross flow nebulizer with double pass spray chamber for ICP-MS. The performance of the new system was studied using the various modes, determining As, Cd, Cu, Fe, Mn and Pb using ICP-AES and Cd, Cu, Hg and Pb using ICP-MS. In the first case NaBH4 was used for hydride generation (of As), and in the second case SnCl2 was used for generation of cold vapor (Hg). For both ICP-AES and ICP-MS, the use of HFR-TMSIS improved the analytical performance of both As and Hg in hydride and cold vapor generation mode, respectively, and also in the dual mode compared to the conventional single mode systems. For the other elements the figure of merits of nebulization and dual mode were comparable with the conventional systems. Cold vapor generation mode (for the determination of Hg) and dual mode (for simultaneous determination of cold vapor of Hg together with other elements) were used for the analysis of various CRMs (digested with HF + HNO3 + H2O2 or HNO3 + H2O2) by ICP-MS.
引用
收藏
页码:158 / 163
页数:6
相关论文
共 50 条
  • [1] Sample introduction systems for the analysis of liquid microsamples by ICP-AES and ICP-MS
    Todoli, Jose L.
    Mermet, Jean M.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2006, 61 (03) : 239 - 283
  • [2] ICP-AES and ICP-MS: Trends and Pittcon'98
    Pecheyran, C
    ANALUSIS, 1998, 26 (04) : M88 - M91
  • [3] A convenient sample introduction system for ICP, ICP-MS, and AA
    McLaughlin, Roger
    Cheese, Paula
    Ding, Min
    Ptolemy, Adam
    Conn, April
    Brindle, Ian
    AMERICAN LABORATORY, 2006, 38 (18) : 13 - +
  • [5] MICROLITER SAMPLE INTRODUCTION FOR ICP-AES
    FASKE, AJ
    SNABLE, KR
    BOORN, AW
    BROWNER, RF
    APPLIED SPECTROSCOPY, 1985, 39 (03) : 542 - 545
  • [6] Multielement Analysis of Oil by ICP-AES and ICP-MS with Microwave-Assisted Sample Preparation
    Grebneva-Balyuk, O. N.
    Kubrakova, I. V.
    Tyutyunnik, O. A.
    Lapshin, S. Yu.
    Pryazhnikov, D. V.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2021, 76 (03) : 306 - 314
  • [7] Provenance establishment of coffee using solution ICP-MS and ICP-AES
    Valentin, Jenna L.
    Watling, R. John
    FOOD CHEMISTRY, 2013, 141 (01) : 98 - 104
  • [8] Study of hypochlorite-specific enhancement in ICP-AES and ICP-MS
    Jia, XJ
    Wang, TB
    Bu, XD
    Tu, Q
    Spencer, S
    Gong, XY
    Natishan, T
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2005, 20 (11) : 1293 - 1295
  • [9] On-line coupling of ion chromatography with ICP-AES and ICP-MS
    Seubert, A
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2001, 20 (6-7) : 274 - 287
  • [10] ICP-MS/ICP-AES测定水中偏硅酸含量
    赵雯玮
    刘吉爱
    朱红波
    李辉
    曹叶伟
    程昌蓉
    李姣
    检验检疫学刊, 2017, 27 (01) : 10 - 12