Lead isotopic analysis of Antarctic snow by quadrupole ICP-MS using a total-consumption sample introduction system

被引:4
|
作者
Ardini, Francisco [1 ]
Bazzano, Andrea [1 ]
Grotti, Marco [1 ]
机构
[1] Univ Genoa, Dept Chem & Ind Chem, Via Dodecaneso 31, I-16146 Genoa, Italy
关键词
PLASMA-MASS SPECTROMETRY; DYNAMIC REACTION CELL; DOME-C; SHEATHING GAS; LAW DOME; DUST; METALS; EPICA; CORE; CLIMATE;
D O I
10.1039/c8ja00296g
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Measurement of lead isotope ratios in snow samples using inductively coupled plasma-dynamic reaction cell-mass spectrometry (ICP-DRC-MS) at a low sample consumption rate was thoroughly studied. Sample volumes were reduced from 20.0 to 0.200 mL by freeze-drying, and the pre-concentrates were efficiently introduced into the plasma source at 20 mu L min(-1) by using the heated torch-integrated sample introduction system (hTISIS). In addition, the DRC was pressurised with neon to improve the precision by collisional damping. Sensitivity was maximised by optimising the operating parameters of the sample introduction system (nebulizer/sheathing gas flow rate ratio), the reaction cell (rod offset and damping gas flow rate) and the signal measurement conditions. The developed method was then characterised in terms of the analytical working range, accuracy and uncertainty estimation. Under the optimal conditions, isotope ratios did not differ in the 0.1-20 mu g L-1 range. Internal precision, expressed as relative standard deviation, varied from 0.12 to 0.18% (c = 10 mu g L-1; n = 12), while the external precision was <0.1%. The potential influence of the pre-concentration procedure on the analytical data was carefully investigated in terms of blank contribution, recovery and isotopic fractionation. The lowest Pb concentration needed in the samples to limit the influence of the blanks within an experimental precision of 0.5% was 4.4 pg g(-1), and the recovery of five standard reference solutions with a Pb concentration of 100 ng L-1 was 90 +/- 5%, with no significant isotopic fractionation. The developed ICP-DRC-MS method was finally applied to a number of representative Antarctic snow samples previously characterised by multi-collector ICP-MS, obtaining a satisfactory agreement between the data provided by the two techniques and analytical results consistent with literature data on the glaciochemistry of Antarctic ice cores.
引用
收藏
页码:2124 / 2132
页数:9
相关论文
共 50 条
  • [21] Sample introduction systems for the analysis of liquid microsamples by ICP-AES and ICP-MS
    Todoli, Jose L.
    Mermet, Jean M.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2006, 61 (03) : 239 - 283
  • [22] Inductively coupled plasma tandem mass spectrometry (ICP-MS/MS) for the analysis of fuels, biofuels and their feedstock using a high temperature total consumption sample introduction system operated under continuous sample aspiration mode
    Martinez, Santiago
    Sanchez, Raquel
    Todoli, Jose-Luis
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2022, 37 (05) : 1032 - 1043
  • [23] Direct quantification of total sulfur dioxide in wine using triple quadrupole ICP-MS
    Wang, Xiao-wei
    Liu, Jing-fu
    Wang, Xiao-yan
    Shao, Bing
    Liu, Li-ping
    Zhang, Jing
    ANALYTICAL METHODS, 2015, 7 (07) : 3224 - 3228
  • [24] The direct analysis of fuel ethanol by ICP-MS using a flow injection system coupled to an ultrasonic nebulizer for sample introduction
    Saint'Pierre, Tatiana D.
    Tormen, Luciano
    Frescura, Vera L. A.
    Curtius, Adilson J.
    Journal of Analytical Atomic Spectrometry, 2006, 21 (11): : 1340 - 1344
  • [25] The direct analysis of fuel ethanol by ICP-MS using a flow injection system coupled to an ultrasonic nebulizer for sample introduction
    Saint'Pierre, Tatiana D.
    Tormen, Luciano
    Frescura, Vera L. A.
    Curtius, Adilson J.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2006, 21 (11) : 1340 - 1344
  • [26] The effects of residual carbon on the determination of chromium in blood and tissue sample, using quadrupole ICP-MS
    Kunze, J
    Wimmer, MA
    Reich, M
    Koelling, S
    Jacobs, JJ
    ATOMIC SPECTROSCOPY, 2005, 26 (01) : 8 - 13
  • [27] Effective Removal of Isobaric Interferences on Strontium and Lead Using Triple-Quadrupole ICP-MS
    Kutscher, Daniel
    Lofthouse, Simon
    Nelms, Simon
    Ducos, Shona McSheehy
    SPECTROSCOPY, 2017, 32 (10) : 38 - 41
  • [28] Sequential digestion for measuring leachable and total lead in the same sample of dust or paint chips by ICP-MS
    Le Bot, Barbara
    Arcelin, Claire
    Briand, Emmanuel
    Glorennec, Philippe
    JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH PART A-TOXIC/HAZARDOUS SUBSTANCES & ENVIRONMENTAL ENGINEERING, 2011, 46 (01): : 63 - 69
  • [29] Total Arsenic, Cadmium, and Lead Determination in Brazilian Rice Samples Using ICP-MS
    Verola Mataveli, Lidiane Raquel
    Buzzo, Marcia Liane
    de Arauz, Luciana Juncioni
    Henriques Carvalho, Maria de Fatima
    Kumagai Arakaki, Edna Emy
    Matsuzaki, Richard
    Tiglea, Paulo
    JOURNAL OF ANALYTICAL METHODS IN CHEMISTRY, 2016, 2016
  • [30] Multielement analysis of micro-volume biological samples by ICP-MS with highly efficient sample introduction system
    Takasaki, Yuka
    Inagaki, Kazumi
    Sabarudin, Akhmad
    Fujii, Shin-Ichiro
    Iwahata, Daigo
    Takatsu, Akiko
    Chiba, Koichi
    Umemura, Tomonari
    TALANTA, 2011, 87 : 24 - 29