Partial volume correction of lung nodules using PET/CT

被引:0
|
作者
Bradley, W. [1 ]
Wendt, R. [1 ]
Pan, T. [1 ]
Erasmus, J. [1 ]
White, R. [1 ]
Mawlawi, O. [1 ]
机构
[1] Univ Texas, MD Anderson Canc Ctr, Houston, TX 77030 USA
关键词
D O I
10.1118/1.2761365
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Partial voluming in PET imaging leads to underestimation in activity concentration. The aim of this abstract is to correct for partial volume artifacts in PET/CT scans. Method and Materials: A Jaszczak phantom with hollow spheres of varying sizes (4.95 – 31.27 mm inner diameter (ID)) was filled with F‐18 water using 3 different sphere‐to‐background ratios (SBR), ranging from 3:1 to 10:1. For each SBR, several acquisitions were conducted. All PET data was reconstructed using OSEM (2 iterations, 21 subsets). Regions were drawn on the CT images to obtain accurate sphere volume and location. A software tool was written to correct for partial voluming by incorporating the sphere size and the non‐stationary response function of the scanner. The original maximum (OM), original average (OA), corrected maximum (CM), and corrected average (CA) activity concentrations (AC) were measured and compared. Results: For all SBRs, spheres larger than 19 mm the measured OM and OA AC were 111 and 77% of the true value, respectively. Following correction, these values changed to 128 (CM) and 102% (CA), respectively. For the smallest sphere size (4.95 mm), the measured OM and OA AC were both 20% of the true value. Following correction, these values changed to 121 (CM) and 104% (CA) of the true value. The CM, however, did vary between 83 and 176% of the true AC. An analytical relationship between the lesion size (obtained from CT) and the amount of correction needed to recover the true AC based on the multiple acquisitions was generated. Conclusions: To determine the true AC of a lesion from a PET/CT scan, the corrected average is more accurate than the original maximum, and should be used for clinical assessment. © 2007, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2553 / 2553
页数:1
相关论文
共 50 条
  • [41] Partial Volume Correction Using Continuous Wavelet Technique in Small Animal PET Imaging
    Arhjoul, Lahcen
    Sarrhini, Otman
    Bentourkia, M'hamed
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 2717 - 2721
  • [42] Partial Volume Correction of PET-Imaged Tumor Heterogeneity Using Expectation Maximization
    Barbee, D.
    Flynn, R.
    Holden, J.
    Jeraj, R.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [43] Management of Lung Nodules Detected by Volume CT Scanning REPLY
    van Klaveren, Rob
    Oudkerk, Matthijs
    de Koning, Harry
    NEW ENGLAND JOURNAL OF MEDICINE, 2010, 362 (08): : 758 - 759
  • [44] Nonlinear partial volume artifact correction in helical CT
    Hsieh, JA
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1999, 46 (03) : 743 - 747
  • [45] ASSESSMENT AND CORRECTION OF PARTIAL VOLUME EFFECT IN SPECT/CT
    Chicco, A.
    Lin, P.
    Som, S.
    INTERNAL MEDICINE JOURNAL, 2015, 45 : 1 - 2
  • [46] Enhanced diagnostic performance of FDG PET/CT using delayed time point imaging and partial volume effect correction of quantitative PET parameters: a lesion-based analysis of suspected lung lesions
    Salavati, A.
    Houshmand, S.
    Khiewvan, B.
    Cheng, G.
    Akers, S. R.
    Werner, T. J.
    Alavi, A.
    JOURNAL OF NUCLEAR MEDICINE, 2015, 56 (02) : 1 - 1
  • [47] A recovery coefficient method for partial volume correction of PET images
    Shyam M. Srinivas
    Thiruvenkatasamy Dhurairaj
    Sandip Basu
    Gonca Bural
    Suleman Surti
    Abass Alavi
    Annals of Nuclear Medicine, 2009, 23 : 341 - 348
  • [48] Correction for partial volume averaging of noisy PET data.
    Slifstein, M
    Mawlawi, O
    Laruelle, M
    JOURNAL OF NUCLEAR MEDICINE, 1999, 40 (05) : 117P - 117P
  • [49] Reproducibility of radiomics features in partial volume correction of PET images
    Azimi, Mohammad-Saber
    Kamali-Asl, Alireza
    Ay, Mohammad-Reza
    Hosseini, Mahboube Sadat
    Khorshidi, Fatemeh
    Arabi, Hossein
    Rahmim, Arman
    Zaidi, Habib
    JOURNAL OF NUCLEAR MEDICINE, 2023, 64
  • [50] Partial volume correction in brain PET-FDG studies
    Prieto, E.
    Marti-Climent, J. M.
    Gomez-Fernandez, M.
    Lecumberri, P.
    Bustince, H.
    Arbizu, J.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2006, 33 : S148 - S148