Partial volume correction of lung nodules using PET/CT

被引:0
|
作者
Bradley, W. [1 ]
Wendt, R. [1 ]
Pan, T. [1 ]
Erasmus, J. [1 ]
White, R. [1 ]
Mawlawi, O. [1 ]
机构
[1] Univ Texas, MD Anderson Canc Ctr, Houston, TX 77030 USA
关键词
D O I
10.1118/1.2761365
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Partial voluming in PET imaging leads to underestimation in activity concentration. The aim of this abstract is to correct for partial volume artifacts in PET/CT scans. Method and Materials: A Jaszczak phantom with hollow spheres of varying sizes (4.95 – 31.27 mm inner diameter (ID)) was filled with F‐18 water using 3 different sphere‐to‐background ratios (SBR), ranging from 3:1 to 10:1. For each SBR, several acquisitions were conducted. All PET data was reconstructed using OSEM (2 iterations, 21 subsets). Regions were drawn on the CT images to obtain accurate sphere volume and location. A software tool was written to correct for partial voluming by incorporating the sphere size and the non‐stationary response function of the scanner. The original maximum (OM), original average (OA), corrected maximum (CM), and corrected average (CA) activity concentrations (AC) were measured and compared. Results: For all SBRs, spheres larger than 19 mm the measured OM and OA AC were 111 and 77% of the true value, respectively. Following correction, these values changed to 128 (CM) and 102% (CA), respectively. For the smallest sphere size (4.95 mm), the measured OM and OA AC were both 20% of the true value. Following correction, these values changed to 121 (CM) and 104% (CA) of the true value. The CM, however, did vary between 83 and 176% of the true AC. An analytical relationship between the lesion size (obtained from CT) and the amount of correction needed to recover the true AC based on the multiple acquisitions was generated. Conclusions: To determine the true AC of a lesion from a PET/CT scan, the corrected average is more accurate than the original maximum, and should be used for clinical assessment. © 2007, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2553 / 2553
页数:1
相关论文
共 50 条
  • [11] Importance of correction for the partial volume effect in lung cancer PET studies
    Pournazari, Kamyar
    Jahangiri, Pegah
    Saboury, Babak
    Khosravi, Mohsen
    Al-zaghal, Abdullah
    Torigian, Drew
    Alavi, Abass
    JOURNAL OF NUCLEAR MEDICINE, 2018, 59
  • [12] Partial Volume Correction Strategies in PET
    Rousset, Olivier
    Rahmim, Arman
    Alavi, Abass
    Zaidi, Habib
    PET CLINICS, 2007, 2 (02) : 235 - 249
  • [13] Partial volume correction of PET scans using a segmented high resolution CT or MR scan.
    Svarer, C
    Willendrup, P
    Holm, S
    Knudsen, GM
    JOURNAL OF NUCLEAR MEDICINE, 2001, 42 (05) : 192P - 192P
  • [14] Influence of partial volume correction in staging of head and neck squamous cell carcinoma using PET/CT
    Fayad, H.
    Le Pogam, A.
    Lamare, F.
    Fernandez, P.
    Pradier, O.
    Valette, G.
    Visvikis, D.
    Le Rest, C. Cheze
    QUARTERLY JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2014, 58 (03): : 319 - 328
  • [15] Accuracy and Precision of Partial-Volume Correction in Oncological PET/CT Studies
    Cysouw, Matthijs C. F.
    Kramer, Gerbrand Maria
    Hoekstra, Otto S.
    Frings, Virginie
    de Langen, Adrianus Johannes
    Smit, Egbert F.
    van den Eertwegh, Alfons J. M.
    Oprea-Lager, Daniela E.
    Boellaard, Ronald
    JOURNAL OF NUCLEAR MEDICINE, 2016, 57 (10) : 1642 - 1649
  • [16] Correction coefficients for partial volume effects of a PET/CT scanner: An empirical study
    Belakhlef, Sam
    Church, Clifford
    Lakhanpal, Suresh
    JOURNAL OF NUCLEAR MEDICINE, 2014, 55
  • [17] Correction coefficients for partial volume effects of a PET/CT scanner: An empirical study
    Belakhlef, Sam
    Church, Clifford
    Lakhanpal, Suresh
    JOURNAL OF NUCLEAR MEDICINE, 2014, 55
  • [18] A simple correction method for the partial volume effect in Discovery STE PET/CT
    Mitsumoto, Tatsuya
    Mizoguchi, Noriko
    Himuro, Kazuhiko
    Sakaguchi, Yuichi
    Kaneko, Koichiro
    Onizuka, Yoshihiko
    Sasaki, Masayuki
    JOURNAL OF NUCLEAR MEDICINE, 2009, 50
  • [19] CT based partial volume correction in (11)C-PiB PET/CT imaging
    Imabavashi, Etsuko
    Matsuda, Hiroshi
    Kuji, Ichiei
    Seto, Akira
    Ito, Kimiteru
    Shimano, Yasumasa
    Yamada, Minoru
    JOURNAL OF NUCLEAR MEDICINE, 2010, 51
  • [20] Hot lung nodules on PET-CT
    Sannier, Aurelie
    Cazes, Aurelie
    Mordant, Pierre
    Boutboul, David
    Borie, Raphael
    Danel, Claire
    ANNALES DE PATHOLOGIE, 2017, 37 (04) : 327 - 331