Partial volume correction of lung nodules using PET/CT

被引:0
|
作者
Bradley, W. [1 ]
Wendt, R. [1 ]
Pan, T. [1 ]
Erasmus, J. [1 ]
White, R. [1 ]
Mawlawi, O. [1 ]
机构
[1] Univ Texas, MD Anderson Canc Ctr, Houston, TX 77030 USA
关键词
D O I
10.1118/1.2761365
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Partial voluming in PET imaging leads to underestimation in activity concentration. The aim of this abstract is to correct for partial volume artifacts in PET/CT scans. Method and Materials: A Jaszczak phantom with hollow spheres of varying sizes (4.95 – 31.27 mm inner diameter (ID)) was filled with F‐18 water using 3 different sphere‐to‐background ratios (SBR), ranging from 3:1 to 10:1. For each SBR, several acquisitions were conducted. All PET data was reconstructed using OSEM (2 iterations, 21 subsets). Regions were drawn on the CT images to obtain accurate sphere volume and location. A software tool was written to correct for partial voluming by incorporating the sphere size and the non‐stationary response function of the scanner. The original maximum (OM), original average (OA), corrected maximum (CM), and corrected average (CA) activity concentrations (AC) were measured and compared. Results: For all SBRs, spheres larger than 19 mm the measured OM and OA AC were 111 and 77% of the true value, respectively. Following correction, these values changed to 128 (CM) and 102% (CA), respectively. For the smallest sphere size (4.95 mm), the measured OM and OA AC were both 20% of the true value. Following correction, these values changed to 121 (CM) and 104% (CA) of the true value. The CM, however, did vary between 83 and 176% of the true AC. An analytical relationship between the lesion size (obtained from CT) and the amount of correction needed to recover the true AC based on the multiple acquisitions was generated. Conclusions: To determine the true AC of a lesion from a PET/CT scan, the corrected average is more accurate than the original maximum, and should be used for clinical assessment. © 2007, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2553 / 2553
页数:1
相关论文
共 50 条
  • [31] Detectability of malignant lung nodules on FDG PET-CT: Impact of attenuation correction on visual interpretation
    Khandani, A. H.
    Rich, A. W.
    Parker, L. A.
    Ivanovic, M.
    McCartney, W. H.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2007, 34 : S173 - S173
  • [32] Correction of partial volume effect in the projections in PET studies
    Guillette, Nicolas
    Sarrhini, Otman
    Lecomte, Roger
    Bentourkia, M'hamed
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 3541 - 3543
  • [33] Correction for partial volume effects in PET: Principle and validation
    Rousset, OG
    Ma, YL
    Evans, AC
    JOURNAL OF NUCLEAR MEDICINE, 1998, 39 (05) : 904 - 911
  • [34] Extravascular density model for PET partial volume correction
    Wassenaar, Richard W.
    deKemp, Robert A.
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 1809 - 1813
  • [35] Comparison of lung lesion volume by PET and CT
    Schiepers, C
    Yue, D
    Dahlborn, M
    Brown, M
    McNitt-Gray, M
    Phelps, ME
    Czernin, J
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 2001, 28 (08): : 1064 - 1064
  • [36] Volume of lung lesions by combining PET and CT
    Schiepers, C
    Dahlbom, M
    Brown, MS
    McNitt-Gray, MF
    Phelps, M
    Czernin, J
    RADIOLOGY, 2002, 225 : 332 - 332
  • [37] Tissue fraction correction for lung PET/CT
    Lambrou, T.
    Groves, A. M.
    Erlandsson, K.
    Screaton, N.
    Endozo, R.
    Win, T.
    Porter, J. C.
    Hutton, B. F.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2011, 38 : S133 - S133
  • [38] A Correction of Partial Volume Effect for Using PET to Define Metabolically Active Tumor Volume for Pancreatic Cancer
    Dalah, E.
    Cungeng, Y.
    Moraru, I.
    Erickson, B.
    Li, X.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [39] Use of prospective gating in PET/CT imaging of lung nodules
    Wojtylak, Patrick
    Faulhaber, Peter
    JOURNAL OF NUCLEAR MEDICINE, 2009, 50
  • [40] Partial volume effect correction in PET image using iterative deconvolution and shearlet transform
    Jomaa, Hajer
    Mabrouk, Rostom
    Khlifa, Nawres
    2018 4TH INTERNATIONAL CONFERENCE ON ADVANCED TECHNOLOGIES FOR SIGNAL AND IMAGE PROCESSING (ATSIP), 2018,