Nonlinear partial volume artifact correction in helical CT

被引:11
|
作者
Hsieh, JA [1 ]
机构
[1] GE, Med Syst, Appl Sci Lab, Milwaukee, WI 53201 USA
关键词
D O I
10.1109/23.775608
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Partial volume (PV) artifacts occur when a scanned object is partially intruded into the scan plane. Because of the nonlinear effect of the PV, computed tomography (CT) images become unsuitable for diagnosis due to severe shading and streaking artifacts. In this paper, we present an iterative correction algorithm to combat these artifacts in helical scans. The algorithm first identifies potential partial volume objects by examining the object gradient based on multiple halfscan reconstructed images. Projection error is then estimated using a quadratic model. The final image is obtained by removing the error image (reconstructed with the projection error) from the original image. Various experiments were conducted to investigate the robustness and effectiveness of the proposed correction.
引用
收藏
页码:743 / 747
页数:5
相关论文
共 50 条
  • [1] Reduced partial volume artifact helical head CT by ''Minute'' Reconstruction
    Sato, N
    Gono, M
    Horiuchi, T
    Miura, S
    Hosoi, J
    RADIOLOGY, 1997, 205 : 314 - 314
  • [2] Joint correction of respiratory motion artifact and partial volume effect in lung PET/CT imaging
    Chang, Guoping
    Chang, Tingting
    Clark, John
    Mawlawi, Osama
    JOURNAL OF NUCLEAR MEDICINE, 2010, 51
  • [3] Iterative approach to the partial volume artifact reduction in CT
    Hsieh, J
    MEDICAL IMAGING 1998: IMAGE PROCESSING, PTS 1 AND 2, 1998, 3338 : 338 - 346
  • [4] Joint correction of respiratory motion artifact and partial volume effect in lung/thoracic PET/CT imaging
    Chang, Guoping
    Chang, Tingting
    Pan, Tinsu
    Clark, John W., Jr.
    Mawlawi, Osama R.
    MEDICAL PHYSICS, 2010, 37 (12) : 6221 - 6232
  • [5] Correction of a new type of artifact in helical multi-slice CT
    Zmora, I
    Taguchi, K
    Silver, MD
    Han, KS
    RADIOLOGY, 1998, 209P : 434 - 435
  • [6] Adaptive Upsampling with Shift Method for Windmill Artifact Correction in Multislice Helical CT
    Zamyatin, Alexander A.
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 3570 - 3572
  • [7] A quantitative measure of CT helical artifact
    Toth, TL
    Simoni, P
    RADIOLOGY, 2001, 221 : 218 - 218
  • [8] Partial-Volume Effect and a Partial-Volume Correction for the NanoPET/CT™ Preclinical PET/CT Scanner
    Szanda, Istvan
    Livieratos, Lefteris
    Patay, Gergely
    Tsoumpas, Charalampos
    Sunassee, Kavitha
    Mullen, Gregory E.
    Nemeth, Gabor
    Major, Peter
    Marsden, Paul K.
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 3605 - 3609
  • [9] ASSESSMENT AND CORRECTION OF PARTIAL VOLUME EFFECT IN SPECT/CT
    Chicco, A.
    Lin, P.
    Som, S.
    INTERNAL MEDICINE JOURNAL, 2015, 45 : 1 - 2
  • [10] Partial volume and aliasing artefacts in helical cone-beam CT
    Zou, Y
    Sidky, EY
    Pan, XC
    PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (11): : 2365 - 2375