Exergoeconomic analysis of a solar assisted ground-source heat pump greenhouse heating system

被引:92
|
作者
Ozgener, O [1 ]
Hepbasli, A
机构
[1] Ege Univ, Solar Energy Inst, TR-35100 Izmir, Turkey
[2] Ege Univ, Dept Engn Mech, TR-35100 Izmir, Turkey
关键词
heat pump; exergy; energy; exergoeconomic; renewable energy;
D O I
10.1016/j.applthermaleng.2004.09.015
中图分类号
O414.1 [热力学];
学科分类号
摘要
EXCEM analysis may prove useful to investigators in engineering and other disciplines due to the methodology are being based on the quantities exergy, cost, energy and mass. The main objective of the present study is to investigate between capital costs and thermodynamic losses for devices in solar assisted ground-source heat pump greenhouse heating system (SAGSHPGHS) with a 50 m vertical 32 mm nominal diameter U-bend ground heat exchanger. This system was designed and installed at the Solar Energy Institute, Ege University, Izmir, Turkey. Thermodynamic loss rate-to-capital cost ratios are used to show that, for components and the overall system, a systematic correlation appears to exist between capital cost and exergy loss (total or internal), but not between capital cost and energy loss or external exergy loss. This correlation may imply that devices in successful air conditioning are configured so as to achieve an overall optimal design, by appropriately balancing the thermodynamic (exergy-based) and economic characteristics of the overall system and its devices. The results may (i) provide useful insights into the relations between thermodynamics and economics, both in general and for SAGSHPGHS, (ii) help demonstrate the merits of second-law analysis. It is observed from the results that the maximum exergy destructions in the system particularly occur due to the electrical, mechanical and isentropic efficiencies and emphasize the need for paying close attention to the selection of this type of equipment, since components of inferior performance can considerably reduce the overall performance of the system. In conjunction with this, the total exergy losses values are obtained to be from 0.010 kW to 0.480 kW for the system. As expected, the largest energy and exergy losses occur in the greenhouse and compressor. The ratio of thermodynamic loss rate to capital cost values are obtained for a range from 0.035 to 1.125. (c) 2004 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1459 / 1471
页数:13
相关论文
共 50 条
  • [41] Energy performances of a ground-source heat pump system
    Minea, V
    [J]. RESEARCH, DESIGN AND CONSTRUCTION OF REFRIGERATION AND AIR CONDITIONING EQUIPMENTS IN EASTERN EUROPEAN COUNTRIES, 1996, : 116 - 125
  • [42] Research of combined heating and cooling by solar ground-source heat pump and PCM thermal storage
    Wu, Li-xia
    Zheng, Mao-yu
    [J]. Solar Engineering 2005, 2006, : 275 - 282
  • [43] Comparison of different strategies for operating a solar-assisted ground-source CO2 heat pump system for space and water heating
    Sazon, Thor Alexis
    Zhang, Qian
    Nikpey, Homam
    [J]. ENERGY CONVERSION AND MANAGEMENT-X, 2024, 22
  • [44] Thermodynamic analysis of solar-assisted ground source heat pump system
    Zheng, Rongjin
    Zhuang, Lin
    Chi, Qing
    Sun, Wenjun
    Zhang, Anlai
    Fu, Lixia
    [J]. Zheng, R. (rongjinzheng@zju.edu.cn), 1600, Chinese Society of Agricultural Machinery (44): : 233 - 238
  • [45] Simulation of the thermal performance of a hybrid solar-assisted ground-source heat pump system in a school building
    Androulakis, N. D.
    Armen, K. G.
    Bozis, D. A.
    Papakostas, K. T.
    [J]. INTERNATIONAL JOURNAL OF SUSTAINABLE ENERGY, 2018, 37 (04) : 311 - 324
  • [46] Thermodynamic analysis and assessment of space heating with Ground-Source Heat Pump for sustainable future
    Ozturk, Murat
    Elbir, Ahmet
    Ozek, Nuri
    Yakut, Ali Kemal
    [J]. INTERNATIONAL JOURNAL OF EXERGY, 2012, 11 (01) : 52 - 68
  • [47] Thermoeconomic analysis of ground-source heat pump systems
    Kwak, Ho-Young
    You, Yungpil
    Oh, Si-Doek
    Jang, Ha-Na
    [J]. INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2014, 38 (02) : 259 - 269
  • [48] EXERGY ANALYSIS OF A RADIANT CEILING ASSISTED GROUND-SOURCE HEAT PUMP AIR-CONDITIONING SYSTEM
    Sui, Xuemin
    Zhang, Xu
    Lin, Ting
    [J]. FIFTH INTERNATIONAL WORKSHOP ON ENERGY AND ENVIRONMENT OF RESIDENTIAL BUILDINGS AND THIRD INTERNATIONAL CONFERENCE ON BUILT ENVIRONMENT AND PUBLIC HEALTH, VOL I AND II, PROCEEDINGS, 2009, : 1844 - 1851
  • [49] Numerical Simulation of Solar Ground-Source Heat Pump with Latent Heat Storage
    Wang, Fang
    Liu, Zhilong
    Li, Zhongjian
    Zheng, Maoyu
    [J]. MATERIALS AND MANUFACTURING TECHNOLOGY, PTS 1 AND 2, 2010, 129-131 : 1069 - +
  • [50] Heating requirements in greenhouse farming in southern Italy: evaluation of ground-source heat pump utilization compared to traditional heating systems
    D'Arpa, Stefania
    Colangelo, Gianpiero
    Starace, Giuseppe
    Petrosillo, Irene
    Bruno, Delia Evelina
    Uricchio, Vito
    Zurlini, Giovanni
    [J]. ENERGY EFFICIENCY, 2016, 9 (05) : 1065 - 1085