Exergoeconomic analysis of a solar assisted ground-source heat pump greenhouse heating system

被引:92
|
作者
Ozgener, O [1 ]
Hepbasli, A
机构
[1] Ege Univ, Solar Energy Inst, TR-35100 Izmir, Turkey
[2] Ege Univ, Dept Engn Mech, TR-35100 Izmir, Turkey
关键词
heat pump; exergy; energy; exergoeconomic; renewable energy;
D O I
10.1016/j.applthermaleng.2004.09.015
中图分类号
O414.1 [热力学];
学科分类号
摘要
EXCEM analysis may prove useful to investigators in engineering and other disciplines due to the methodology are being based on the quantities exergy, cost, energy and mass. The main objective of the present study is to investigate between capital costs and thermodynamic losses for devices in solar assisted ground-source heat pump greenhouse heating system (SAGSHPGHS) with a 50 m vertical 32 mm nominal diameter U-bend ground heat exchanger. This system was designed and installed at the Solar Energy Institute, Ege University, Izmir, Turkey. Thermodynamic loss rate-to-capital cost ratios are used to show that, for components and the overall system, a systematic correlation appears to exist between capital cost and exergy loss (total or internal), but not between capital cost and energy loss or external exergy loss. This correlation may imply that devices in successful air conditioning are configured so as to achieve an overall optimal design, by appropriately balancing the thermodynamic (exergy-based) and economic characteristics of the overall system and its devices. The results may (i) provide useful insights into the relations between thermodynamics and economics, both in general and for SAGSHPGHS, (ii) help demonstrate the merits of second-law analysis. It is observed from the results that the maximum exergy destructions in the system particularly occur due to the electrical, mechanical and isentropic efficiencies and emphasize the need for paying close attention to the selection of this type of equipment, since components of inferior performance can considerably reduce the overall performance of the system. In conjunction with this, the total exergy losses values are obtained to be from 0.010 kW to 0.480 kW for the system. As expected, the largest energy and exergy losses occur in the greenhouse and compressor. The ratio of thermodynamic loss rate to capital cost values are obtained for a range from 0.035 to 1.125. (c) 2004 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1459 / 1471
页数:13
相关论文
共 50 条
  • [11] Experimental investigation of a ground-source heat pump system for greenhouse heating-cooling
    Harjunowibowo, Dewanto
    Omer, Siddig A.
    Riffat, Saffa B.
    [J]. INTERNATIONAL JOURNAL OF LOW-CARBON TECHNOLOGIES, 2021, 16 (04) : 1529 - 1541
  • [12] A parametrical study on the energetic and exergetic assessment of a solar-assisted vertical ground-source heat pump system used for heating a greenhouse
    Ozgener, Onder
    Hepbasli, Arif
    [J]. BUILDING AND ENVIRONMENT, 2007, 42 (01) : 11 - 24
  • [13] Thermodynamic analysis of a ground-source heat pump system for district heating
    Hepbasli, A
    [J]. INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2005, 29 (07) : 671 - 687
  • [14] Evaluation of ground-source heat pump combined latent heat storage system performance in greenhouse heating
    Benli, Hueseyin
    Durmus, Aydin
    [J]. ENERGY AND BUILDINGS, 2009, 41 (02) : 220 - 228
  • [15] Heating system of biogas digester by ground-source heat pump
    Shi H.
    Wang T.
    Zhu H.
    Li Y.
    Rong L.
    Pei X.
    [J]. Nongye Gongcheng Xuebao/Transactions of the Chinese Society of Agricultural Engineering, 2010, 26 (02): : 268 - 273
  • [16] Application of phase change material in solar assisted ground-source heat pump system
    Wang, Fang
    Zheng, Maoyu
    Li, Zhongjian
    Lei, Bangwei
    [J]. Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2006, 27 (12): : 1231 - 1234
  • [17] Photovoltaic and solar-assisted ground-source heat pump systems
    Varney, Kevin E.
    Vahdati, Maria M.
    [J]. PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-ENGINEERING SUSTAINABILITY, 2013, 166 (01) : 32 - 45
  • [18] Analysis of the operation performance of a hybrid solar ground-source heat pump system
    Zhang, Xueyou
    Wang, Enyu
    Liu, Liansheng
    Qi, Chengying
    Zhen, Jinyu
    Meng, Ying
    [J]. ENERGY AND BUILDINGS, 2022, 268
  • [19] Numerical simulation of solar assisted ground-source heat pump heating system with latent heat energy storage in severely cold area
    Han, Zongwei
    Zheng, Maoyu
    Kong, Fanhong
    Wang, Fang
    Li, Zhongjian
    Bai, Tian
    [J]. APPLIED THERMAL ENGINEERING, 2008, 28 (11-12) : 1427 - 1436
  • [20] RESEARCH AND APPLICATION OF SOLAR-ASSISTED GROUND-SOURCE HEAT PUMP HYBRID SYSTEM IN CHINA
    Gong, Xue-Mei
    [J]. ENERGY AND MECHANICAL ENGINEERING, 2016, : 227 - 237