Exergoeconomic analysis of a solar assisted ground-source heat pump greenhouse heating system

被引:92
|
作者
Ozgener, O [1 ]
Hepbasli, A
机构
[1] Ege Univ, Solar Energy Inst, TR-35100 Izmir, Turkey
[2] Ege Univ, Dept Engn Mech, TR-35100 Izmir, Turkey
关键词
heat pump; exergy; energy; exergoeconomic; renewable energy;
D O I
10.1016/j.applthermaleng.2004.09.015
中图分类号
O414.1 [热力学];
学科分类号
摘要
EXCEM analysis may prove useful to investigators in engineering and other disciplines due to the methodology are being based on the quantities exergy, cost, energy and mass. The main objective of the present study is to investigate between capital costs and thermodynamic losses for devices in solar assisted ground-source heat pump greenhouse heating system (SAGSHPGHS) with a 50 m vertical 32 mm nominal diameter U-bend ground heat exchanger. This system was designed and installed at the Solar Energy Institute, Ege University, Izmir, Turkey. Thermodynamic loss rate-to-capital cost ratios are used to show that, for components and the overall system, a systematic correlation appears to exist between capital cost and exergy loss (total or internal), but not between capital cost and energy loss or external exergy loss. This correlation may imply that devices in successful air conditioning are configured so as to achieve an overall optimal design, by appropriately balancing the thermodynamic (exergy-based) and economic characteristics of the overall system and its devices. The results may (i) provide useful insights into the relations between thermodynamics and economics, both in general and for SAGSHPGHS, (ii) help demonstrate the merits of second-law analysis. It is observed from the results that the maximum exergy destructions in the system particularly occur due to the electrical, mechanical and isentropic efficiencies and emphasize the need for paying close attention to the selection of this type of equipment, since components of inferior performance can considerably reduce the overall performance of the system. In conjunction with this, the total exergy losses values are obtained to be from 0.010 kW to 0.480 kW for the system. As expected, the largest energy and exergy losses occur in the greenhouse and compressor. The ratio of thermodynamic loss rate to capital cost values are obtained for a range from 0.035 to 1.125. (c) 2004 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1459 / 1471
页数:13
相关论文
共 50 条
  • [21] Study on Hybrid Solar Energy and Ground-Source Heat Pump System
    Liu Yi
    Li Bing-xi
    Zhou Yi
    Fu Zhong-bin
    Xu Xin-hai
    [J]. ICEET: 2009 INTERNATIONAL CONFERENCE ON ENERGY AND ENVIRONMENT TECHNOLOGY, VOL 1, PROCEEDINGS, 2009, : 845 - 848
  • [22] Performance prediction of a hybrid solar ground-source heat pump system
    Wang, Enyu
    Fung, Alan S.
    Qi, Chengying
    Leong, Wey H.
    [J]. ENERGY AND BUILDINGS, 2012, 47 : 600 - 611
  • [23] NUMERICAL INVESTIGATION ON FREE COOLING PERFORMANCE OF GROUND-SOURCE HEAT PUMP IN A SOLAR GREENHOUSE
    Hou, Zhao
    Hu, Yuqiu
    Liu, Xiaojie
    Wang, Jianhua
    Yang, Mei
    Fan, Jun
    [J]. THERMAL SCIENCE, 2023, 27 (6A): : 4719 - 4732
  • [24] HEATING APPLICATION AND ENVIRONMENTAL BENEFIT OF SOLAR-ASSISTED GROUND-SOURCE HEAT PUMP WITH SEASONAL ENERGY STORAGE
    Wei, Cuixia
    Wang, Zhichao
    Ma, Kunru
    Wu, Pin
    Yu, Ruijiao
    Hao, Qi
    Wu, Cuigu
    [J]. JOURNAL OF ENVIRONMENTAL PROTECTION AND ECOLOGY, 2021, 22 (02): : 588 - 601
  • [25] Exergy analysis of a hybrid ground-source heat pump system
    Menberg, Kathrin
    Heo, Yeonsook
    Choi, Wonjun
    Ooka, Ryozo
    Choudhary, Ruchi
    Shukuya, Masanori
    [J]. APPLIED ENERGY, 2017, 204 : 31 - 46
  • [26] A feasible system integrating combined heating and power system with ground-source heat pump
    Li, HongQiang
    Kang, ShuShuo
    Yu, Zhun
    Cai, Bo
    Zhang, GuoQiang
    [J]. ENERGY, 2014, 74 : 240 - 247
  • [27] Simplified method to determine the collector area of solar-assisted ground-source heat pump system
    Ji, Yongming
    Lin Duanmu
    Li, Xiangli
    Airaksinen, Miimu
    Wang, Zongshan
    [J]. 10TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, ISHVAC2017, 2017, 205 : 1138 - 1145
  • [28] Linear active disturbance rejection control of solar heating system assisted by ground-source heat pumps
    Wang, Zhigang
    Cheng, Jiaguang
    Zhang, Qingnan
    Wang, Pan
    Wang, Yan
    [J]. 9TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING (ISHVAC) JOINT WITH THE 3RD INTERNATIONAL CONFERENCE ON BUILDING ENERGY AND ENVIRONMENT (COBEE), 2015, 121 : 809 - 815
  • [29] Performance Study of a Hybrid Solar-Assisted Ground-Source Heat Pump System Used for Building Heating and Hot Water Demands
    Berkane, Ahleme
    Aksas, Mounir
    Aouachria, Zeroual.
    [J]. JORDAN JOURNAL OF MECHANICAL AND INDUSTRIAL ENGINEERING, 2023, 17 (04): : 581 - 594
  • [30] Study on the methods for predicting the performance of a hybrid solar-assisted ground-source heat pump system
    Zhuang, Zhaoyi
    Zhu, Qiqi
    Song, Jian
    Zhang, Xin
    Li, Haorong
    [J]. 10TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, ISHVAC2017, 2017, 205 : 3879 - 3886