Research of combined heating and cooling by solar ground-source heat pump and PCM thermal storage

被引:0
|
作者
Wu, Li-xia [1 ]
Zheng, Mao-yu [1 ]
机构
[1] Harbin Inst Technol, Sch Municipal & Environm Engn, Harbin 150090, Heilongjiang, Peoples R China
来源
关键词
solar energy; ground-source heat pump; temperature field; PCM thermal storage; heating and cooling;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In severely cold climate, significant amount of energy is used to heat buildings. Both the theoretical computation and experiments show that it is difficult and uneconomical to use solar energy collected merely in winter. A new method has been developed to store solar energy during summer, fall, and spring for winter heating. This paper presents in details the combined heating and cooling system by solar ground-source heat pump (GSHP) and short-term phase change material (PCM) thermal storage. The hybrid system and season-shift mode can make the sustainable use of solar energy possible. As for the above system, the solar energy collected is stored into soil through the U-tube heat exchanger. In winter, the thermal energy is taken out for heating using the GSHP. At the end of the heat supply season, the underground soil temperature may drop below 0 degrees C. Then some heat exchangers begin to store the heat into soil while others stop. In summer, the U-tube heat exchanger is used to produce low temperature water without compressor to cool the room. The project was supported by the Energy Conservation Laboratory at Harbin Institute of Technology (HIT). The whole systems, which have run for over two years, consist of a flat plate solar hot water system installed on the roof, a soil thermal storage system, a GSHP system, a PCM thermal storage system and heating-cooling system. The measured results show an average heating coefficient of performance (COP) of 3.2 in winter and the cooling coefficient of performance (COP) of 18.0 in summer. The PCM thermal storage system has been investigated by numerical simulation and experiments in the cold climate. In most time of winter, the PCM thermal storage system was used to supply heat, while solar GSHP was also used during continuous cloudy days and severely cold days. The result shows that above method is feasible. The most advantage of this system is that it does not need the usual energy equipment. The numerical analysis has been used to investigate the thermal energy balance of the underground soil. The variation of the soil temperature field around the U-tube heat exchanger has also been studied, not only for the single exchanger but also for multiple exchangers. The underground soil makes the yearly thermal balance possible because the solar energy supplies the heat that is extracted from the soil for heating in winter. Then this system can operate for a long period.
引用
收藏
页码:275 / 282
页数:8
相关论文
共 50 条
  • [1] Thermal equilibrium research of solar seasonal storage system coupling with ground-source heat pump
    Liu, Long
    Zhu, Neng
    Zhao, Jing
    [J]. ENERGY, 2016, 99 : 83 - 90
  • [2] The solar assisted ground-source heat pump heating applied research of cold regions
    Ran, ChunYu
    Wang, Zhe
    Zhang, LiYun
    [J]. ADVANCED RESEARCH ON ENGINEERING MATERIALS, ENERGY, MANAGEMENT AND CONTROL, PTS 1 AND 2, 2012, 424-425 : 844 - 847
  • [3] Ground source heat pump carbon emissions and ground-source heat pump systems for heating and cooling of buildings: A review
    Ahmadi, Mohammad Hossein
    Ahmadi, Mohammad Ali
    Sadaghiani, Mirhadi S.
    Ghazvini, Mahyar
    Shahriar, Sadegh
    Nazari, Mohammad Alhuyi
    [J]. ENVIRONMENTAL PROGRESS & SUSTAINABLE ENERGY, 2018, 37 (04) : 1241 - 1265
  • [4] Evaluation of ground-source heat pump combined latent heat storage system performance in greenhouse heating
    Benli, Hueseyin
    Durmus, Aydin
    [J]. ENERGY AND BUILDINGS, 2009, 41 (02) : 220 - 228
  • [5] Thermal comfort assessment and energy consumption analysis of ground-source heat pump system combined with radiant heating/cooling
    Lu, Shikui
    Zhang, Xiaosong
    [J]. Journal of Southeast University (English Edition), 2012, 28 (01) : 52 - 57
  • [6] Numerical Simulation of Solar Ground-Source Heat Pump with Latent Heat Storage
    Wang, Fang
    Liu, Zhilong
    Li, Zhongjian
    Zheng, Maoyu
    [J]. MATERIALS AND MANUFACTURING TECHNOLOGY, PTS 1 AND 2, 2010, 129-131 : 1069 - +
  • [7] Study of Seasonal Storage in Ground-Source Heat Pump with Solar Collector
    Wang, Fang
    Niu, Lianjing
    Liu, Zhilong
    Zheng, Maoyu
    [J]. FRONTIERS OF MANUFACTURING AND DESIGN SCIENCE II, PTS 1-6, 2012, 121-126 : 2897 - +
  • [8] General review of ground-source heat pump systems for heating and cooling of buildings
    Sarbu, Ioan
    Sebarchievici, Calin
    [J]. ENERGY AND BUILDINGS, 2014, 70 : 441 - 454
  • [9] Experimental investigation of a ground-source heat pump system for greenhouse heating-cooling
    Harjunowibowo, Dewanto
    Omer, Siddig A.
    Riffat, Saffa B.
    [J]. INTERNATIONAL JOURNAL OF LOW-CARBON TECHNOLOGIES, 2021, 16 (04) : 1529 - 1541
  • [10] HEATING APPLICATION AND ENVIRONMENTAL BENEFIT OF SOLAR-ASSISTED GROUND-SOURCE HEAT PUMP WITH SEASONAL ENERGY STORAGE
    Wei, Cuixia
    Wang, Zhichao
    Ma, Kunru
    Wu, Pin
    Yu, Ruijiao
    Hao, Qi
    Wu, Cuigu
    [J]. JOURNAL OF ENVIRONMENTAL PROTECTION AND ECOLOGY, 2021, 22 (02): : 588 - 601