Scanning protocols for multislice CT scanners

被引:16
|
作者
Kulama, E [1 ]
机构
[1] Hammersmith Hosp, RSU, London W12 0HS, England
来源
关键词
D O I
10.1259/bjr/28755689
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The new multislice CT (MSCT) technology enables examinations to be completed with much greater flexibility in terms of shorter times and improved z-axis resolution. For this to be achieved, a very large amount of data may be produced, with implications on the way the data are handled and reviewed. In addition, there is the issue of radiation dose to the patient and the effect that multislice scanning has on it. In this paper, the basic physics principles of MSCT are reviewed and clarification is given why and where these differ from single slice scanning. Examples of scanning protocols are given with reference to patient dose. These protocols vary depending on the make and model of the scanner and the type of examination.
引用
收藏
页码:S2 / S9
页数:8
相关论文
共 50 条
  • [31] Multislice CT angiography
    Schoepf, UJ
    Becker, CR
    Hofmann, LK
    Das, M
    Flohr, T
    Ohnesorge, BM
    Baumert, B
    Rolnick, J
    Allen, JM
    Raptopoulos, V
    EUROPEAN RADIOLOGY, 2003, 13 (08) : 1946 - 1961
  • [32] Multislice CT of the abdomen
    Cahir, JG
    Freeman, AH
    Courtney, HM
    BRITISH JOURNAL OF RADIOLOGY, 2004, 77 : S64 - S73
  • [33] CT: Single and multislice
    Mutic, S
    MEDICAL PHYSICS, 2005, 32 (06) : 2153 - 2153
  • [34] Multislice CT angiography
    U. Joseph Schoepf
    Christoph R. Becker
    Lars K. Hofmann
    Marco Das
    Thomas Flohr
    Bernd M. Ohnesorge
    Bernhard Baumert
    Joshua Rolnick
    Jean M. Allen
    Vassilios Raptopoulos
    European Radiology, 2003, 13 : 1946 - 1961
  • [35] Evolving Bioprosthetic Tissue Calcification Can Be Quantified Using Serial Multislice CT Scanning
    Meuris, B.
    De Praetere, H.
    Coudyzer, W.
    Flameng, W.
    INTERNATIONAL JOURNAL OF BIOMATERIALS, 2013, 2013
  • [36] Multislice CT angiography
    Prokop, M
    EUROPEAN JOURNAL OF RADIOLOGY, 2000, 36 (02) : 86 - 96
  • [37] COMPARISON OF CT SCANNERS
    GOODENOUGH, DJ
    WEAVER, K
    DAVIS, DO
    NEURORADIOLOGY, 1976, 12 (01) : 47 - 47
  • [38] DOSIMETRY OF CT SCANNERS
    CARDEW, APSE
    SOUTHON, FCG
    STEWART, RJJ
    ACKLAND, HS
    AUSTRALASIAN RADIOLOGY, 1980, 24 (02): : 182 - 191
  • [39] Diagnostic accuracy for coronary artery disease of multislice CT scanners in comparison to conventional coronary angiography: An integrative literature review
    Delgado, Karsen
    Williams, Mary
    JOURNAL OF THE AMERICAN ACADEMY OF NURSE PRACTITIONERS, 2010, 22 (09): : 496 - 503
  • [40] ON PROLIFERATION OF CT SCANNERS
    BARTLETT, EE