Scanning protocols for multislice CT scanners

被引:16
|
作者
Kulama, E [1 ]
机构
[1] Hammersmith Hosp, RSU, London W12 0HS, England
来源
关键词
D O I
10.1259/bjr/28755689
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The new multislice CT (MSCT) technology enables examinations to be completed with much greater flexibility in terms of shorter times and improved z-axis resolution. For this to be achieved, a very large amount of data may be produced, with implications on the way the data are handled and reviewed. In addition, there is the issue of radiation dose to the patient and the effect that multislice scanning has on it. In this paper, the basic physics principles of MSCT are reviewed and clarification is given why and where these differ from single slice scanning. Examples of scanning protocols are given with reference to patient dose. These protocols vary depending on the make and model of the scanner and the type of examination.
引用
收藏
页码:S2 / S9
页数:8
相关论文
共 50 条
  • [21] Effect of respiratory motion in CT based attenuation correction in SPECT using different CT scanners and protocols
    Segars, W. Paul
    Tsui, Benjamin M. W.
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 2413 - 2417
  • [22] Whole body 16-row multislice CT in emergency room: Effects of different protocols on scanning time, image quality and radiation exposure
    Fanucci E.
    Fiaschetti V.
    Rotili A.
    Floris R.
    Simonetti G.
    Emergency Radiology, 2007, 13 (5) : 251 - 257
  • [23] A dose reduction X-ray beam positioning system for high speed multislice CT scanners
    Toth, TL
    Bromberg, NB
    Pan, T
    Rabe, JD
    Woloschek, SJ
    Li, J
    RADIOLOGY, 1999, 213P : 284 - 284
  • [24] Multislice CT
    Baque, Pia-Elisabeth
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2021, 193 (02): : 215 - 217
  • [25] Multislice CT
    Morcos, SK
    Weir, J
    BRITISH JOURNAL OF RADIOLOGY, 2004, 77 : S1 - S1
  • [26] Practical experiences in the transfer of clinical protocols between CT scanners with different ATCM systems
    Sookpeng, Supawitoo
    Martin, Colin J.
    Cheebsumon, Patsuree
    Pengpan, Thanyawee
    JOURNAL OF RADIOLOGICAL PROTECTION, 2017, 37 (01) : 84 - 96
  • [27] THE USE OF 4TH GENERATION CT SCANNERS FOR GATED HEART SCANNING
    JOSEPH, PM
    PROCEEDINGS OF THE SOCIETY OF PHOTO-OPTICAL INSTRUMENTATION ENGINEERS, 1982, 372 : 151 - 157
  • [28] Principles of CT: Multislice CT
    Goldman, Lee W.
    JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY, 2008, 36 (02) : 57 - 68
  • [29] A dose reduction x-ray beam positioning system for high-speed multislice CT scanners
    Toth, TL
    Bromberg, NB
    Pan, TS
    Rabe, J
    Woloschek, SJ
    Li, JY
    Seidenschnur, GE
    MEDICAL PHYSICS, 2000, 27 (12) : 2659 - 2668
  • [30] CT angiography of the aorta and its branches: Value of different scan protocols obtained by using a singleslice and a multislice helical CT
    Mueller, C