Scanning protocols for multislice CT scanners

被引:16
|
作者
Kulama, E [1 ]
机构
[1] Hammersmith Hosp, RSU, London W12 0HS, England
来源
关键词
D O I
10.1259/bjr/28755689
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The new multislice CT (MSCT) technology enables examinations to be completed with much greater flexibility in terms of shorter times and improved z-axis resolution. For this to be achieved, a very large amount of data may be produced, with implications on the way the data are handled and reviewed. In addition, there is the issue of radiation dose to the patient and the effect that multislice scanning has on it. In this paper, the basic physics principles of MSCT are reviewed and clarification is given why and where these differ from single slice scanning. Examples of scanning protocols are given with reference to patient dose. These protocols vary depending on the make and model of the scanner and the type of examination.
引用
收藏
页码:S2 / S9
页数:8
相关论文
共 50 条
  • [1] A z gain nonuniformity correction for multislice volumetric CT scanners
    Besson, G
    Hu, H
    Xie, M
    He, D
    Seidenschnur, G
    Bromberg, N
    MEDICAL PHYSICS, 2000, 27 (05) : 873 - 884
  • [2] Considerations on the assessment of myocardial perfusion with multislice spiral CT (MSCT) scanners
    Ulzheimer, S
    Muresan, L
    Kachelriess, M
    Roemer, W
    Achenbach, S
    Kalender, WA
    RADIOLOGY, 2001, 221 : 458 - 458
  • [3] The impact of overscan on patient dose with first generation multislice CT scanners
    Tsalafoutas, Ioannis A.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2011, 27 (02): : 69 - 74
  • [4] Multislice CT scanning with the SOMATOM Volume Zoom
    Flohr, TH
    Klingenbeck-Regn, K
    Ohnesorge, B
    Schaller, S
    MULTISLICE CT: A PRACTICAL GUIDE, 2001, : 7 - 21
  • [5] Multislice CT angiography in post-aortic stent grafting: optimization of scanning protocols for virtual intravascular endoscopy
    Sun, Zhonghua
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2008, 3 (1-2) : 19 - 26
  • [6] Multislice CT angiography in post-aortic stent grafting: optimization of scanning protocols for virtual intravascular endoscopy
    Zhonghua Sun
    International Journal of Computer Assisted Radiology and Surgery, 2008, 3 : 19 - 26
  • [7] Accuracy of automated volumetry of pulmonary nodules across different multislice CT scanners
    Marco Das
    Julia Ley-Zaporozhan
    H. A. Gietema
    Andre Czech
    Georg Mühlenbruch
    Andreas H. Mahnken
    Markus Katoh
    Annemarie Bakai
    Marcos Salganicoff
    Stefan Diederich
    Mathias Prokop
    Hans-Ulrich Kauczor
    Rolf W. Günther
    Joachim E. Wildberger
    European Radiology, 2007, 17 : 1979 - 1984
  • [8] Accuracy of automated volumetry of pulmonary nodules across different multislice CT scanners
    Das, Marco
    Ley-Zaporozhan, Julia
    Gietema, H. A.
    Czech, Andre
    Muehlenbruch, Georg
    Mahnken, Andreas H.
    Katoh, Markus
    Bakai, Annemarie
    Salganicoff, Marcos
    Diederich, Stefan
    Prokop, Mathias
    Kauczor, Hans-Ulrich
    Guenther, Rolf W.
    Wildberger, Joachim E.
    EUROPEAN RADIOLOGY, 2007, 17 (08) : 1979 - 1984
  • [9] Development of pediatric CT protocols for specific scanners: why bother?
    Dianna D. Cody
    Pediatric Radiology, 2014, 44 : 489 - 491
  • [10] Development of pediatric CT protocols for specific scanners: why bother?
    Cody, Dianna D.
    PEDIATRIC RADIOLOGY, 2014, 44 : 489 - 491