Evolving Bioprosthetic Tissue Calcification Can Be Quantified Using Serial Multislice CT Scanning

被引:0
|
作者
Meuris, B. [1 ]
De Praetere, H. [1 ]
Coudyzer, W. [2 ]
Flameng, W. [1 ]
机构
[1] Katholieke Univ Leuven, Dept Cardiovasc Dis, B-3000 Leuven, Belgium
[2] Katholieke Univ Leuven, Dept Radiol, B-3000 Leuven, Belgium
关键词
D O I
10.1155/2013/617329
中图分类号
TB3 [工程材料学]; R318.08 [生物材料学];
学科分类号
0805 ; 080501 ; 080502 ;
摘要
Background. We investigated the value of serial multislice CT scanning for in vivo determination of evolving tissue calcification in three separate experimental settings. Materials and Methods. Bioprosthetic valve tissue was implanted in three different conditions: (1) glutaraldehyde-fixed porcine stentless conduits in pulmonary position (n = 6); (2) glutaraldehyde-fixed stented pericardial valves in mitral position (n = 3); and (3) glutaraldehyde-fixed pericardial tissue as patch in the jugular vein and carotid artery (n = 16). Multislice CT scanning was performed at various time intervals. Results. In stentless conduits, the distribution of wall calcification can be reliably quantified with CT. After 20 weeks, the CT-determined mean calcium volume was 1831 +/- 581 mm(3), with a mean wall calcium content of 89.8 +/- 44.4 mu g/mg (r(2) = 0.68). In stented pericardial valves implanted in mitral position, reliable determination of tissue mineralization is disturbed by scattering caused by the (continuously moving) alloy of the stent material. Pericardial patches in the neck vessels revealed progressive mineralization, with a significant increase in mean HU and calcium volume at 8 weeks after implantation, rising up to a level of 131.1 +/- 39.6 mm(3) (mean calcium volume score) and a mean calcium content of 19.1 +/- 12.3 mu g/mg. Conclusion. The process of bioprosthetic tissue mineralization can be visualized and quantified in vivo using multislice CT scanning. This allows determination of the kinetics of tissue mineralization with intermediate in vivo evaluations.
引用
收藏
页数:7
相关论文
共 35 条
  • [1] PREVENTION OF TISSUE CALCIFICATION ON BIOPROSTHETIC HEART-VALVE BY USING EPOXY COMPOUNDS - A STUDY OF CALCIFICATION TESTS INVITRO AND INVIVO
    XI, TF
    MA, JZ
    TIAN, WH
    LEI, XH
    LONG, SH
    XI, BS
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1992, 26 (09): : 1241 - 1251
  • [2] Can Femoral Rotation Be Localized and Quantified Using Standard CT Measures?
    Georgiadis, Andrew G.
    Siegal, Daniel S.
    Scher, Courtney E.
    Zaltz, Ira
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2015, 473 (04) : 1309 - 1314
  • [3] New treatments using alginate in order to reduce the calcification of bovine bioprosthetic heart valve tissue
    Shanthi, C
    Rao, KP
    JOURNAL OF BIOMATERIALS SCIENCE-POLYMER EDITION, 1997, 8 (12) : 919 - 930
  • [4] Structural Changes in Boreal Forests Can Be Quantified Using Terrestrial Laser Scanning
    Yrttimaa, Tuomas
    Luoma, Ville
    Saarinen, Ninni
    Kankare, Ville
    Junttila, Samuli
    Holopainen, Markus
    Hyyppa, Juha
    Vastaranta, Mikko
    REMOTE SENSING, 2020, 12 (17)
  • [5] A Feldkamp-type approximate algorithm for helical multislice CT using extended scanning helix
    Liang, Hongzhu
    Zhang, Cishen
    Yan, Ming
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2009, 33 (03) : 197 - 204
  • [6] CORR InsightsA®: Can Femoral Rotation Be Localized and Quantified Using Standard CT Measures?
    Radler, Christof
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2015, 473 (04) : 1315 - 1317
  • [7] EPICARDIAL ADIPOSE TISSUE AS A PREDICTOR OF CORONARY ATHEROSCLEROSIS WITHOUT CALCIFICATION USING MULTISLICE COMPUTED TOMOGRAPHY IN ELDERLY PATIENTS
    Harada, Kenji
    Saito, Akihiro
    Okumura, Takanobu
    Kageyama, Norihito
    Yamamoto, Takashi
    Fujinaga, Hiroyuki
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 55 (10)
  • [8] 4D (time-dependent) measurements of breathing motion using multislice CT scanning
    Low, D
    Bradley, J
    Dempsey, J
    Politte, D
    Islam, K
    Mutic, S
    Christensen, G
    Deasy, J
    MEDICAL PHYSICS, 2002, 29 (06) : 1340 - 1340
  • [9] In vivo assessment of attenuation of different plaque tissue components using multislice CT coronary angiography
    Mollet, NR
    Cademartiri, F
    Runza, G
    Lemos, PA
    Baks, T
    Krestin, GP
    De Feyter, PJ
    CIRCULATION, 2004, 110 (17) : 523 - 523
  • [10] Soft tissue discrimination with contrast agents using micro-CT scanning
    Descamps, Emilie
    Sochacka, Alicja
    De Kegel, Barbara
    Van Loo, Denis
    Van Hoorebeke, Luc
    Adriaens, Dominique
    BELGIAN JOURNAL OF ZOOLOGY, 2014, 144 (01): : 20 - 40