Diagnostic Assessment of Normal and Pale Optic Nerve Heads by Confocal Scanning Laser Ophthalmoscope and Stereophotography

被引:3
|
作者
Fogagnolo, Paolo [1 ,2 ]
Romano, Simona [1 ]
Ranno, Stefano [1 ]
Taibbi, Giovanni [1 ]
Pierrottet, Chiara [1 ]
Ferreras, Antonio [4 ]
Figus, Michele [3 ]
Rossetti, Luca [1 ]
Orzalesi, Nicola [1 ]
机构
[1] Univ Milan, San Paolo Hosp, Eye Clin, I-20142 Milan, Italy
[2] IRCCS, GB Bietti Fdn Study & Res Ophthalmol, Rome, Italy
[3] Univ Pisa, Eye Clin, Pisa, Italy
[4] Univ Zaragoza, Miguel Servet Univ Hosp, Dept Ophthalmol, Zaragoza, Spain
关键词
confocal scanning laser ophthalmoscope; stereophotography; glaucoma; image quality; cup/disc ratio; paleness; pallor; neuropathy; retina tomography; HRT; OPEN-ANGLE GLAUCOMA; OCULAR HYPERTENSION; DISC; AGREEMENT; INTRAOBSERVER; PHOTOGRAPHS; ACCURACY; PRESSURE; SIZE;
D O I
10.1097/IJG.0b013e3181d1d221
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate the diagnostic assessment of optic nerve heads (ONH) by stereophotography (SP) and Heidelberg retina tomograph (HRT) in patients with retinitis pigmentosa (RP). Methods: This study involved 53 consecutive patients with RP and 24 controls who underwent ONH examination by SP and HRT. On the basis of the appearance at SP, RP ONH were divided in normal-colored (24/53) and pale (29/53). The measurements of vertical ONH diameter and vertical cup/disc ratio (VCDR) by SP and HRT were compared between the groups by means of t test and Bland-Altman plots. Diagnosis, ONH pallor and size, HRT image quality (image standard deviation, SD) were also inspected as sources of differences in the results by means of a multivariate analysis. Results: Vertical diameter measurements were similar using SP and HRT, respectively (1.93 +/- 0.50 and 1.80 +/- 0.62 for normal-colored ONH, P= 0.43; 2.02 +/- 0.65 and 1.90 +/- 0.40 for pale ONH, P= 0.27; and 1.98 +/- 0.55 and 1.84 +/- 0.52 for controls, P= 0.33). In normal-colored ONH, VCDR was 0.30 +/- 0.11 at SP and 0.31 +/- 0.21 at HRT (P= 0.90); in controls, it was 0.29 +/- 0.13 at SP and 0.30 +/- 0.18 at HRT (P= 0.77). In the group with pale ONH, VCDR was 0.34 +/- 0.14 at SP and 0.53 +/- 0.24 at HRT (P< 0.001). HRT image quality was the only parameter which influenced the difference in VCDR estimates between SP and HRT (P= 0.02). In patients with pale ONH, this difference was significantly higher, when images of acceptable quality were used for analysis (0.36 +/- 0.15 vs. 0.15 +/- 0.21 for images with good quality or better, P= 0.03). Conclusions: In ONH diseases other than glaucoma, HRT may give misleading information when images of acceptable quality are considered for analysis. We therefore recommend the use of images with good quality or better (SD <= 30 mu m) in these cases.
引用
收藏
页码:10 / 14
页数:5
相关论文
共 50 条
  • [41] Research Progress and Application of Confocal Scanning Laser Ophthalmoscope (Invited)
    Ye Xiadi
    Huang Jiangjie
    Kong Wen
    Xing Lina
    He Yi
    Shi Guohua
    [J]. LASER & OPTOELECTRONICS PROGRESS, 2024, 61 (10)
  • [42] MULTICOLOR CONFOCAL SCANNING LASER OPHTHALMOSCOPE IMAGING IN POSTERIOR UVEITIS
    GUPTA, K. A. J. R. E. E.
    AGARWAL, A. N. I. R. U. D. D. H. A.
    ARORA, A. T. U. L.
    AGGARWAL, K. A. N. I. K. A.
    BANSAL, R. E. E. M. A.
    KATOCH, D. E. E. K. S. H. A.
    MARCHESE, A. L. E. S. S. A. N. D. R. O.
    SINGH, S. I. M. A. R. R.
    AGRAWAL, R. U. P. E. S. H.
    GUPTA, V. I. S. H. A. L. I.
    [J]. RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2022, 42 (07): : 1356 - 1363
  • [43] CONFOCAL FUNDUS IMAGING WITH A SCANNING LASER OPHTHALMOSCOPE IN EYES WITH CATARACT
    BECKMAN, C
    BONDTAYLOR, L
    LINDBLOM, B
    SJOSTRAND, J
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 1995, 79 (10) : 900 - 904
  • [44] Confocal scanning laser ophthalmoscope with adaptive optical wavefront correction
    Vohnsen, B
    Iglesias, I
    Artal, P
    [J]. THREE-DIMENSIONAL AND MULTIDIMENSIONAL MICROSCOPY: IMAGE ACQUISITION AND PROCESSING X, 2003, 4964 : 24 - 32
  • [45] ASSESSMENT OF FIXATION STABILITY IN NORMAL SUBJECTS AND PATIENTS USING A SCANNING LASER OPHTHALMOSCOPE
    CULHAM, LE
    FITZKE, FW
    TIMBERLAKE, GT
    MARSHALL, J
    [J]. CLINICAL VISION SCIENCES, 1993, 8 (06): : 551 - 561
  • [46] Sensitivity of Imaging the Peripheral Nerve Fibre Layer using a Confocal Scanning laser Ophthalmoscope to Detect Glaucoma
    Plange, N.
    Kaup, M.
    Hirsch, F.
    Arend, K. O.
    Remky, A.
    [J]. KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2010, 227 (01) : 61 - 66
  • [47] Topographical Analysis of Non-Glaucomatous Myopic Optic Discs Using a Confocal Scanning Laser Ophthalmoscope (TopSS)
    Oh, Seung Hoon
    Chung, Sung Kun
    Lee, Na Young
    [J]. SEMINARS IN OPHTHALMOLOGY, 2015, 30 (5-6) : 397 - 409
  • [48] CONTRAST SENSITIVITY ASSESSMENT WITH A SCANNING LASER OPHTHALMOSCOPE
    FRAMBACH, DA
    SEBAG, J
    LAWTON, TB
    SADUN, AA
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1993, 34 (04) : 1419 - 1419
  • [49] THE SCANNING LASER OPHTHALMOSCOPE AND RETINAL ASSESSMENT IN DIABETES
    POPE, RM
    KING, A
    GEALL, M
    MARTIN, BM
    [J]. DIABETIC MEDICINE, 1993, 10 (05) : 465 - 469
  • [50] Normal values for fundus perimetry with the scanning laser ophthalmoscope
    Rohrschneider, K
    Becker, M
    Schumacher, N
    Fendrich, T
    Völcker, HE
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 1998, 126 (01) : 52 - 58