Diagnostic Assessment of Normal and Pale Optic Nerve Heads by Confocal Scanning Laser Ophthalmoscope and Stereophotography

被引:3
|
作者
Fogagnolo, Paolo [1 ,2 ]
Romano, Simona [1 ]
Ranno, Stefano [1 ]
Taibbi, Giovanni [1 ]
Pierrottet, Chiara [1 ]
Ferreras, Antonio [4 ]
Figus, Michele [3 ]
Rossetti, Luca [1 ]
Orzalesi, Nicola [1 ]
机构
[1] Univ Milan, San Paolo Hosp, Eye Clin, I-20142 Milan, Italy
[2] IRCCS, GB Bietti Fdn Study & Res Ophthalmol, Rome, Italy
[3] Univ Pisa, Eye Clin, Pisa, Italy
[4] Univ Zaragoza, Miguel Servet Univ Hosp, Dept Ophthalmol, Zaragoza, Spain
关键词
confocal scanning laser ophthalmoscope; stereophotography; glaucoma; image quality; cup/disc ratio; paleness; pallor; neuropathy; retina tomography; HRT; OPEN-ANGLE GLAUCOMA; OCULAR HYPERTENSION; DISC; AGREEMENT; INTRAOBSERVER; PHOTOGRAPHS; ACCURACY; PRESSURE; SIZE;
D O I
10.1097/IJG.0b013e3181d1d221
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate the diagnostic assessment of optic nerve heads (ONH) by stereophotography (SP) and Heidelberg retina tomograph (HRT) in patients with retinitis pigmentosa (RP). Methods: This study involved 53 consecutive patients with RP and 24 controls who underwent ONH examination by SP and HRT. On the basis of the appearance at SP, RP ONH were divided in normal-colored (24/53) and pale (29/53). The measurements of vertical ONH diameter and vertical cup/disc ratio (VCDR) by SP and HRT were compared between the groups by means of t test and Bland-Altman plots. Diagnosis, ONH pallor and size, HRT image quality (image standard deviation, SD) were also inspected as sources of differences in the results by means of a multivariate analysis. Results: Vertical diameter measurements were similar using SP and HRT, respectively (1.93 +/- 0.50 and 1.80 +/- 0.62 for normal-colored ONH, P= 0.43; 2.02 +/- 0.65 and 1.90 +/- 0.40 for pale ONH, P= 0.27; and 1.98 +/- 0.55 and 1.84 +/- 0.52 for controls, P= 0.33). In normal-colored ONH, VCDR was 0.30 +/- 0.11 at SP and 0.31 +/- 0.21 at HRT (P= 0.90); in controls, it was 0.29 +/- 0.13 at SP and 0.30 +/- 0.18 at HRT (P= 0.77). In the group with pale ONH, VCDR was 0.34 +/- 0.14 at SP and 0.53 +/- 0.24 at HRT (P< 0.001). HRT image quality was the only parameter which influenced the difference in VCDR estimates between SP and HRT (P= 0.02). In patients with pale ONH, this difference was significantly higher, when images of acceptable quality were used for analysis (0.36 +/- 0.15 vs. 0.15 +/- 0.21 for images with good quality or better, P= 0.03). Conclusions: In ONH diseases other than glaucoma, HRT may give misleading information when images of acceptable quality are considered for analysis. We therefore recommend the use of images with good quality or better (SD <= 30 mu m) in these cases.
引用
收藏
页码:10 / 14
页数:5
相关论文
共 50 条
  • [31] Superresolution in adaptive optics confocal scanning laser ophthalmoscope
    Lu Jing
    Li Hao
    He Yi
    Shi Guo-Hua
    Zhang Yu-Dong
    [J]. ACTA PHYSICA SINICA, 2011, 60 (03)
  • [32] Oral fluorescein angiography with the confocal scanning laser ophthalmoscope
    Garcia, CR
    Rivero, ME
    Bartsch, DU
    Ishiko, S
    Takamiya, A
    Fukui, K
    Hirokawa, H
    Clark, T
    Yoshida, A
    Freeman, WR
    [J]. OPHTHALMOLOGY, 1999, 106 (06) : 1114 - 1118
  • [33] IMAGING RETINAL DENSITOMETRY WITH A CONFOCAL SCANNING LASER OPHTHALMOSCOPE
    VANNORREN, D
    VANDEKRAATS, J
    [J]. VISION RESEARCH, 1989, 29 (12) : 1825 - 1830
  • [34] CONFOCAL LASER SCANNING OPHTHALMOSCOPE - AUTOMATIC REGISTRATION AND REPRODUCIBILITY
    CIOFF, GA
    EASTMAN, RD
    ROBIN, AL
    PERELL, HF
    KELMAN, SE
    SARFARAZI, F
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1991, 32 (04) : 719 - 719
  • [35] Fundus Autofluorescence in Optic Disc Drusen: Comparison of Confocal Scanning Laser Ophthalmoscope and Standard Fundus Camera
    Dinc, Umut Asli
    Tatlipinar, Sinan
    Gorgun, Ebru
    Yenerel, Melda
    [J]. NEURO-OPHTHALMOLOGY, 2009, 33 (06) : 318 - 321
  • [36] Topography of fundus autofluorescence using a confocal scanning laser ophthalmoscope
    Bellmann, C
    Holt, FG
    Schapp, O
    Volcker, HE
    Otto, TP
    [J]. OPHTHALMOLOGE, 1997, 94 (06): : 385 - 391
  • [37] Tomographic reconstruction of the retina using a confocal scanning laser ophthalmoscope
    Vieira, P
    Manivannan, A
    Lim, CS
    Sharp, P
    Forrester, JV
    [J]. PHYSIOLOGICAL MEASUREMENT, 1999, 20 (01) : 1 - 19
  • [38] Improvement of confocal scanning laser ophthalmoscope images using polarimetry
    Campbell, MCW
    Bueno, JM
    Hunter, JJ
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2002, 43 : U209 - U209
  • [39] Fundus autofluorescence mapping using a confocal scanning laser ophthalmoscope
    Bindewald, A
    Schmitz-Valckenberg, S
    Holz, FG
    [J]. MACULA: DIAGNOSIS, TREATMENT AND FUTURE TRENDS, 2004, : 239 - 245
  • [40] Polarimetric high-resolution confocal scanning laser ophthalmoscope
    Bueno, JM
    Vohnsen, B
    [J]. VISION RESEARCH, 2005, 45 (28) : 3526 - 3534