Diagnostic Assessment of Normal and Pale Optic Nerve Heads by Confocal Scanning Laser Ophthalmoscope and Stereophotography

被引:3
|
作者
Fogagnolo, Paolo [1 ,2 ]
Romano, Simona [1 ]
Ranno, Stefano [1 ]
Taibbi, Giovanni [1 ]
Pierrottet, Chiara [1 ]
Ferreras, Antonio [4 ]
Figus, Michele [3 ]
Rossetti, Luca [1 ]
Orzalesi, Nicola [1 ]
机构
[1] Univ Milan, San Paolo Hosp, Eye Clin, I-20142 Milan, Italy
[2] IRCCS, GB Bietti Fdn Study & Res Ophthalmol, Rome, Italy
[3] Univ Pisa, Eye Clin, Pisa, Italy
[4] Univ Zaragoza, Miguel Servet Univ Hosp, Dept Ophthalmol, Zaragoza, Spain
关键词
confocal scanning laser ophthalmoscope; stereophotography; glaucoma; image quality; cup/disc ratio; paleness; pallor; neuropathy; retina tomography; HRT; OPEN-ANGLE GLAUCOMA; OCULAR HYPERTENSION; DISC; AGREEMENT; INTRAOBSERVER; PHOTOGRAPHS; ACCURACY; PRESSURE; SIZE;
D O I
10.1097/IJG.0b013e3181d1d221
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate the diagnostic assessment of optic nerve heads (ONH) by stereophotography (SP) and Heidelberg retina tomograph (HRT) in patients with retinitis pigmentosa (RP). Methods: This study involved 53 consecutive patients with RP and 24 controls who underwent ONH examination by SP and HRT. On the basis of the appearance at SP, RP ONH were divided in normal-colored (24/53) and pale (29/53). The measurements of vertical ONH diameter and vertical cup/disc ratio (VCDR) by SP and HRT were compared between the groups by means of t test and Bland-Altman plots. Diagnosis, ONH pallor and size, HRT image quality (image standard deviation, SD) were also inspected as sources of differences in the results by means of a multivariate analysis. Results: Vertical diameter measurements were similar using SP and HRT, respectively (1.93 +/- 0.50 and 1.80 +/- 0.62 for normal-colored ONH, P= 0.43; 2.02 +/- 0.65 and 1.90 +/- 0.40 for pale ONH, P= 0.27; and 1.98 +/- 0.55 and 1.84 +/- 0.52 for controls, P= 0.33). In normal-colored ONH, VCDR was 0.30 +/- 0.11 at SP and 0.31 +/- 0.21 at HRT (P= 0.90); in controls, it was 0.29 +/- 0.13 at SP and 0.30 +/- 0.18 at HRT (P= 0.77). In the group with pale ONH, VCDR was 0.34 +/- 0.14 at SP and 0.53 +/- 0.24 at HRT (P< 0.001). HRT image quality was the only parameter which influenced the difference in VCDR estimates between SP and HRT (P= 0.02). In patients with pale ONH, this difference was significantly higher, when images of acceptable quality were used for analysis (0.36 +/- 0.15 vs. 0.15 +/- 0.21 for images with good quality or better, P= 0.03). Conclusions: In ONH diseases other than glaucoma, HRT may give misleading information when images of acceptable quality are considered for analysis. We therefore recommend the use of images with good quality or better (SD <= 30 mu m) in these cases.
引用
收藏
页码:10 / 14
页数:5
相关论文
共 50 条
  • [21] CONFOCAL SCANNING LASER OPHTHALMOSCOPE WITH A SLIT APERTURE
    KOBAYASHI, K
    NAKANO, H
    MATSUI, H
    AKIYAMA, K
    ASAKURA, T
    [J]. MEASUREMENT SCIENCE AND TECHNOLOGY, 1991, 2 (04) : 287 - 292
  • [22] Scanning laser polarimetry of edematous and atrophic optic nerve heads
    Banks, MC
    Robe-Collignon, NJ
    Rizzo, JF
    Pasquale, LR
    [J]. ARCHIVES OF OPHTHALMOLOGY, 2003, 121 (04) : 484 - 490
  • [23] Optimization of confocal scanning laser ophthalmoscope design
    LaRocca, Francesco
    Dhalla, Al-Hafeez
    Kelly, Michael P.
    Farsiu, Sina
    Izatt, Joseph A.
    [J]. JOURNAL OF BIOMEDICAL OPTICS, 2013, 18 (07)
  • [24] Spectrally encoded confocal scanning laser ophthalmoscope
    Tao, Yuankai K.
    Izatt, Joseph A.
    [J]. OPHTHALMIC TECHNOLOGIES XX, 2010, 7550
  • [25] Slope analysis of the optic disc in eyes with ocular hypertension and early normal tension glaucoma by confocal scanning laser ophthalmoscope
    Dong, J
    Chihara, E
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 2001, 85 (01) : 56 - 62
  • [26] COMPUTERIZED STEREOIMAGE BY CONFOCAL LASER SCANNING OPHTHALMOSCOPE
    FUNATSU, H
    MISHIMA, HK
    KIUCHI, Y
    KANEDA, K
    YAMASHITA, H
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1993, 34 (04) : 1506 - 1506
  • [27] Observer dependent diagnostic variability of optic nerve head measurements with confocal laser scanning tomography
    Diestelhorst, M
    Burk, ROW
    Garway-Heath, DF
    Jonas, JB
    Jonescu-Cuypers, CP
    Mardin, CY
    Funk, J
    Hermann, MM
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2002, 43 : U222 - U222
  • [28] Confocal scanning of the optic laser Doppler flowmetry nerve in smokers
    Erb, C
    Orgül, S
    Griesser, S
    Lietz, A
    Hendrickson, P
    Flammer, J
    [J]. NEURO-OPHTHALMOLOGY, 1999, 21 (01) : 33 - 37
  • [29] Confocal scanning laser ophthalmoscopy and the screening of optic nerve pathology
    Alyabyeva, Zh. Yu.
    Agaptseva, O. V.
    [J]. 2018 INTERNATIONAL CONFERENCE LASER OPTICS (ICLO 2018), 2018, : 521 - 521
  • [30] CONFOCAL IMAGING OF THE FUNDUS USING A SCANNING LASER OPHTHALMOSCOPE
    WOON, WH
    FITZKE, FW
    BIRD, AC
    MARSHALL, J
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 1992, 76 (08) : 470 - 474