Diagnostic Assessment of Normal and Pale Optic Nerve Heads by Confocal Scanning Laser Ophthalmoscope and Stereophotography

被引:3
|
作者
Fogagnolo, Paolo [1 ,2 ]
Romano, Simona [1 ]
Ranno, Stefano [1 ]
Taibbi, Giovanni [1 ]
Pierrottet, Chiara [1 ]
Ferreras, Antonio [4 ]
Figus, Michele [3 ]
Rossetti, Luca [1 ]
Orzalesi, Nicola [1 ]
机构
[1] Univ Milan, San Paolo Hosp, Eye Clin, I-20142 Milan, Italy
[2] IRCCS, GB Bietti Fdn Study & Res Ophthalmol, Rome, Italy
[3] Univ Pisa, Eye Clin, Pisa, Italy
[4] Univ Zaragoza, Miguel Servet Univ Hosp, Dept Ophthalmol, Zaragoza, Spain
关键词
confocal scanning laser ophthalmoscope; stereophotography; glaucoma; image quality; cup/disc ratio; paleness; pallor; neuropathy; retina tomography; HRT; OPEN-ANGLE GLAUCOMA; OCULAR HYPERTENSION; DISC; AGREEMENT; INTRAOBSERVER; PHOTOGRAPHS; ACCURACY; PRESSURE; SIZE;
D O I
10.1097/IJG.0b013e3181d1d221
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate the diagnostic assessment of optic nerve heads (ONH) by stereophotography (SP) and Heidelberg retina tomograph (HRT) in patients with retinitis pigmentosa (RP). Methods: This study involved 53 consecutive patients with RP and 24 controls who underwent ONH examination by SP and HRT. On the basis of the appearance at SP, RP ONH were divided in normal-colored (24/53) and pale (29/53). The measurements of vertical ONH diameter and vertical cup/disc ratio (VCDR) by SP and HRT were compared between the groups by means of t test and Bland-Altman plots. Diagnosis, ONH pallor and size, HRT image quality (image standard deviation, SD) were also inspected as sources of differences in the results by means of a multivariate analysis. Results: Vertical diameter measurements were similar using SP and HRT, respectively (1.93 +/- 0.50 and 1.80 +/- 0.62 for normal-colored ONH, P= 0.43; 2.02 +/- 0.65 and 1.90 +/- 0.40 for pale ONH, P= 0.27; and 1.98 +/- 0.55 and 1.84 +/- 0.52 for controls, P= 0.33). In normal-colored ONH, VCDR was 0.30 +/- 0.11 at SP and 0.31 +/- 0.21 at HRT (P= 0.90); in controls, it was 0.29 +/- 0.13 at SP and 0.30 +/- 0.18 at HRT (P= 0.77). In the group with pale ONH, VCDR was 0.34 +/- 0.14 at SP and 0.53 +/- 0.24 at HRT (P< 0.001). HRT image quality was the only parameter which influenced the difference in VCDR estimates between SP and HRT (P= 0.02). In patients with pale ONH, this difference was significantly higher, when images of acceptable quality were used for analysis (0.36 +/- 0.15 vs. 0.15 +/- 0.21 for images with good quality or better, P= 0.03). Conclusions: In ONH diseases other than glaucoma, HRT may give misleading information when images of acceptable quality are considered for analysis. We therefore recommend the use of images with good quality or better (SD <= 30 mu m) in these cases.
引用
收藏
页码:10 / 14
页数:5
相关论文
共 50 条
  • [1] Assessment of optic nerve head topographic parameters with a confocal scanning laser ophthalmoscope
    Durukan, AH
    Yucel, I
    Akar, Y
    Bayraktar, MZ
    [J]. CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2004, 32 (03): : 259 - 264
  • [2] CONFOCAL LASER SCANNING OPHTHALMOSCOPE - REPRODUCIBILITY OF OPTIC-NERVE HEAD TOPOGRAPHIC MEASUREMENTS WITH THE CONFOCAL LASER SCANNING OPHTHALMOSCOPE
    CIOFFI, GA
    ROBIN, AL
    EASTMAN, RD
    PERELL, HF
    SAFARAZI, FA
    KELMAN, SE
    [J]. OPHTHALMOLOGY, 1993, 100 (01) : 57 - 62
  • [3] Analysis of optic nerve head by confocal scanning laser ophthalmoscope in ocular hypertension
    Kria, L
    Beltaief, O
    Farah, H
    Anane, R
    Erraies, K
    Karray, F
    Boussen, IM
    Chkir, R
    Zhioua, R
    Ouertani, AM
    [J]. JOURNAL FRANCAIS D OPHTALMOLOGIE, 2004, 27 (09): : 995 - 999
  • [4] Reproducibility of the measurements of the optic nerve head topographic variables with a confocal scanning laser ophthalmoscope
    Akar, Y
    Orhan, M
    Irkeç, M
    [J]. JAPANESE JOURNAL OF OPHTHALMOLOGY, 2003, 47 (02) : 173 - 177
  • [5] Evaluation of optic nerve damage in diabetic patients by confocal scanning laser ophthalmoscope.
    Chihara, E
    Dong, J
    Liu, X
    Ochiai, H
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1997, 38 (04) : 1630 - 1630
  • [6] Optic nerve head analysis using the confocal scanning laser ophthalmoscope (CSLO) of big cups versus normal cups
    Ouertani, A.
    Tounsi, L.
    Khammari, C.
    Bouden, J.
    Mili-Boussen, I.
    [J]. JOURNAL FRANCAIS D OPHTALMOLOGIE, 2009, 32 (01): : 50 - 55
  • [7] Comparison of optic nerve head measurement by optical coherence tomography and confocal scanning laser ophthalmoscope
    Kee, C
    Yong, PC
    Taek, KY
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 : U109 - U109
  • [8] Assessment of retinal autofluorescence with a confocal scanning laser ophthalmoscope
    Wolf, S
    Knabben, H
    Solbach, U
    Kirchhof, B
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1997, 38 (04) : 1595 - 1595
  • [9] CONFOCAL SCANNING LASER OPHTHALMOSCOPE
    WEBB, RH
    HUGHES, GW
    DELORI, FC
    [J]. APPLIED OPTICS, 1987, 26 (08): : 1492 - 1499
  • [10] CONFOCAL SCANNING LASER OPHTHALMOSCOPE
    WEBB, RH
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1986, 3 (13): : P52 - P52