CONFOCAL LASER SCANNING OPHTHALMOSCOPE - REPRODUCIBILITY OF OPTIC-NERVE HEAD TOPOGRAPHIC MEASUREMENTS WITH THE CONFOCAL LASER SCANNING OPHTHALMOSCOPE

被引:0
|
作者
CIOFFI, GA
ROBIN, AL
EASTMAN, RD
PERELL, HF
SAFARAZI, FA
KELMAN, SE
机构
[1] LOYOLA COLL,BALTIMORE,MD
[2] UNIV MARYLAND,GLAUCOMA SERV,BALTIMORE,MD 21201
[3] JOHNS HOPKINS UNIV,WILMER EYE INST,GLAUCOMA SERV,BALTIMORE,MD 21218
[4] SINAI HOSP,GLAUCOMA SERV,BALTIMORE,MD 21215
关键词
D O I
暂无
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background. Glaucoma is an optic neuropathy in which changes in the appearance of both the optic nerve head and the surrounding tissues are important in both diagnosing its presence and progression. Accurate methods to objectively document the appearance of the optic nerve are necessary. The confocal laser scanning ophthalmoscope (Zeiss) is a new prototype instrument that may have the capability to accurately perform this function. Methods: The authors performed a prospective pilot study evaluating the ability of the confocal laser scanning ophthalmoscope to reproduce three-dimensional optic nerve images. Each retinal image contained 600,000 bytes of information. Thirty discrete images of the right optic nerves of 19 visually normal volunteers were obtained. Depth measurements were compared from the same 100 x 100 mum areas (neighborhoods). Results: Image comparisons found the variability of depth measurements for the entire image were within 102 mum (95% confidence interval). Sixty percent of the depth measurements were reproducible within 1 00 mum. Variability of the depth measurements was greatest where the neuroretinal rim sloped at the edge of the optic cup and lowest in the peripapillary area. Conclusion: The confocal laser scanning ophthalmoscope has the potential to be a safe, rapid, and reproducible method of imaging ocular structures.
引用
收藏
页码:57 / 62
页数:6
相关论文
共 50 条
  • [1] Reproducibility of the measurements of the optic nerve head topographic variables with a confocal scanning laser ophthalmoscope
    Akar, Y
    Orhan, M
    Irkeç, M
    [J]. JAPANESE JOURNAL OF OPHTHALMOLOGY, 2003, 47 (02) : 173 - 177
  • [2] Assessment of optic nerve head topographic parameters with a confocal scanning laser ophthalmoscope
    Durukan, AH
    Yucel, I
    Akar, Y
    Bayraktar, MZ
    [J]. CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2004, 32 (03): : 259 - 264
  • [3] Analysis of optic nerve head by confocal scanning laser ophthalmoscope in ocular hypertension
    Kria, L
    Beltaief, O
    Farah, H
    Anane, R
    Erraies, K
    Karray, F
    Boussen, IM
    Chkir, R
    Zhioua, R
    Ouertani, AM
    [J]. JOURNAL FRANCAIS D OPHTALMOLOGIE, 2004, 27 (09): : 995 - 999
  • [4] CONFOCAL SCANNING LASER OPHTHALMOSCOPE
    WEBB, RH
    HUGHES, GW
    DELORI, FC
    [J]. APPLIED OPTICS, 1987, 26 (08): : 1492 - 1499
  • [5] CONFOCAL SCANNING LASER OPHTHALMOSCOPE
    WEBB, RH
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1986, 3 (13): : P52 - P52
  • [6] CONFOCAL LASER SCANNING OPHTHALMOSCOPE - AUTOMATIC REGISTRATION AND REPRODUCIBILITY
    CIOFF, GA
    EASTMAN, RD
    ROBIN, AL
    PERELL, HF
    KELMAN, SE
    SARFARAZI, F
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1991, 32 (04) : 719 - 719
  • [7] EFFECT OF REFERENCE PLANE CHANGES ON OPTIC-NERVE HEAD TOPOGRAPHY MEASURED BY A CONFOCAL SCANNING LASER OPHTHALMOSCOPE
    SHAKIBA, S
    ZANGWILL, L
    GARDEN, V
    WEINREB, RN
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1995, 36 (04) : S627 - S627
  • [8] REPRODUCIBILITY OF TOPOGRAPHIC MEASUREMENTS OF THE MACULA WITH A SCANNING LASER OPHTHALMOSCOPE
    MENEZES, AV
    GIUNTA, M
    CHISHOLM, L
    HARVEY, PT
    TULI, R
    DEVENYI, RG
    [J]. OPHTHALMOLOGY, 1995, 102 (02) : 230 - 235
  • [9] Accommodation to a confocal scanning laser ophthalmoscope
    Kelly, JP
    Seibel, E
    Schowengerdt, B
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 : U11 - U11
  • [10] Reproducibility of fundus autofluorescence measurements obtained using a confocal scanning laser ophthalmoscope
    Lois, N
    Halfyard, AS
    Bunce, C
    Bird, AC
    Fitzke, FW
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 1999, 83 (03) : 276 - 279