Automatic liver detection and standardised uptake value evaluation in whole-body Positron Emission Tomography/Computed Tomography scans

被引:6
|
作者
Chauvie, Stephane [1 ]
Bertone, Elisa [1 ]
Bergesio, Fabrizio [1 ]
Terulla, Alessandra [1 ]
Botto, Davide [2 ]
Cerello, Piergiorgio [3 ]
机构
[1] Santa Croce & Carle Hosp, Med Phys Unit Div, Cuneo, Italy
[2] Politecn Torino, Dipartimento Sci Applicata & Tecnol, Turin, Italy
[3] Ist Nazl Fis Nucl, Sez Torino, Turin, Italy
关键词
Positron Emission Tomography; SUV; Liver; Quality control; PET/CT;
D O I
10.1016/j.cmpb.2017.12.026
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Background and objective: Standardised Uptake Value (SUV), in clinical research and practice, is a marker of tumour avidity in Positron Emission Tomography/Computed Tomography (PET/CT). Since many technical , physical and physiological factors affect the SUV absolute measurement, the liver uptake is often used as reference value both in quantitative and semi-quantitative evaluation. The purpose of this investigation was to automatically detect the liver position in whole-body PET/CT scans and extract its average SUV value.& para;& para;Methods: We developed an algorithm, called Liver DEtection Algorithm (LIDEA), that analyses PET/CT scans, and under the assumption that the liver is a large homogeneous volume near the centre of mass of the patient, finds its position and automatically places a region of interest (ROI) in the liver, which is used to calculate the average SUV. The algorithm was validated on a population of 630 PET/CT scans coming from more than 60 different scanners. The SUV was also calculated by manually placing a large ROI in the liver.& para;& para;Results: LIDEA identified the liver with a 97.3% sensitivity with PET/CT images only and reached a 98.9% correct detection rate when using the co-registered CT scan to avoid liver misidentification in the right lung.& para;& para;The average liver SUV obtained with LIDEA was successfully validated against its manual assessment, with no systematic difference (0.11 +/- 0.36 SUV units) and a R-2 = 0.89 correlation coefficient.& para;& para;Conclusions: LIDEA proved to be a reliable tool to automatically identify and extract the average SUV of the liver in oncological whole-body PET/CT scans. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:47 / 52
页数:6
相关论文
共 50 条
  • [41] A clinical evaluation of the quantitative accuracy of simultaneous emission/transmission scanning in whole-body positron emission tomography
    Martin A. Lodge
    Ramsey D. Badawi
    Paul K. Marsden
    European Journal of Nuclear Medicine, 1998, 25 : 417 - 423
  • [42] Informativeness of whole-body diffusion-weighted magnetic resonance imaging and positron emission tomography with computed tomography in follicular lymphoma
    Nesterova, E. S.
    Yatsyk, G. A.
    Lutsik, N. S.
    Kravchenko, S. K.
    Sudarikov, A. B.
    Krasilonikova, I., V
    Gemdzhian, E. G.
    Kovrigina, A. M.
    TERAPEVTICHESKII ARKHIV, 2020, 92 (07) : 55 - 62
  • [43] A clinical evaluation of the quantitative accuracy of simultaneous emission/transmission scanning in whole-body positron emission tomography
    Lodge, MA
    Badawi, RD
    Marsden, PK
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1998, 25 (04) : 417 - 423
  • [44] Whole-body FDG positron emission tomographic imaging for staging esophageal cancer - Comparison with computed tomography
    Meltzer, CC
    Luketich, JD
    Friedman, D
    Charron, M
    Strollo, D
    Meehan, M
    Urso, GK
    Dachille, MA
    Townsend, DW
    CLINICAL NUCLEAR MEDICINE, 2000, 25 (11) : 882 - 887
  • [45] Maximum standardised uptake value of positron emission tomography as a predictor of oesophageal cancer outcomes
    Lai, Hsing-Hua
    Ho, Wei
    Lo, Chien-Ming
    Chuang, Kai-Hao
    Chen, Yu
    Chen, Li-Chun
    Lu, Hung-, I
    JOURNAL OF CARDIOTHORACIC SURGERY, 2024, 19 (01)
  • [46] Volumetric model and human observer comparisons of tumor detection for whole-body positron emission tomography
    Lartizien, C
    Kinahan, PE
    Comtat, C
    ACADEMIC RADIOLOGY, 2004, 11 (06) : 637 - 648
  • [47] Glucose uptake by individual skeletal muscles during running using whole-body positron emission tomography
    Toshihiko Fujimoto
    Masatoshi Itoh
    Manabu Tashiro
    Keiichiro Yamaguchi
    Kazuo Kubota
    Hiroaki Ohmori
    European Journal of Applied Physiology, 2000, 83 : 297 - 302
  • [48] Glucose uptake by individual skeletal muscles during running using whole-body positron emission tomography
    Fujimoto, T
    Itoh, M
    Tashiro, M
    Yamaguchi, K
    Kubota, K
    Ohmori, H
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2000, 83 (4-5) : 297 - 302
  • [49] Complementary Prognostic Value of Pelvic Magnetic Resonance Imaging and Whole-Body Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography in the Pretreatment Assessment of Patients With Cervical Cancer
    Sala, Evis
    Micco, Maura
    Burger, Irene A.
    Yakar, Derya
    Kollmeier, Marisa A.
    Goldman, Debra A.
    Gonen, Mithat
    Park, Kay J.
    Abu-Rustum, Nadeem R.
    Hricak, Hedvig
    Vargas, Hebert Alberto
    INTERNATIONAL JOURNAL OF GYNECOLOGICAL CANCER, 2015, 25 (08) : 1461 - 1467
  • [50] Diagnostic and prognostic value of independent and combined detection of computed tomography, ultrasound, and positron emission tomography - computed tomography in lymphoma
    Shi, Lihong
    Hu, Haihua
    SLAS TECHNOLOGY, 2024, 29 (04):