Automatic liver detection and standardised uptake value evaluation in whole-body Positron Emission Tomography/Computed Tomography scans

被引:6
|
作者
Chauvie, Stephane [1 ]
Bertone, Elisa [1 ]
Bergesio, Fabrizio [1 ]
Terulla, Alessandra [1 ]
Botto, Davide [2 ]
Cerello, Piergiorgio [3 ]
机构
[1] Santa Croce & Carle Hosp, Med Phys Unit Div, Cuneo, Italy
[2] Politecn Torino, Dipartimento Sci Applicata & Tecnol, Turin, Italy
[3] Ist Nazl Fis Nucl, Sez Torino, Turin, Italy
关键词
Positron Emission Tomography; SUV; Liver; Quality control; PET/CT;
D O I
10.1016/j.cmpb.2017.12.026
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Background and objective: Standardised Uptake Value (SUV), in clinical research and practice, is a marker of tumour avidity in Positron Emission Tomography/Computed Tomography (PET/CT). Since many technical , physical and physiological factors affect the SUV absolute measurement, the liver uptake is often used as reference value both in quantitative and semi-quantitative evaluation. The purpose of this investigation was to automatically detect the liver position in whole-body PET/CT scans and extract its average SUV value.& para;& para;Methods: We developed an algorithm, called Liver DEtection Algorithm (LIDEA), that analyses PET/CT scans, and under the assumption that the liver is a large homogeneous volume near the centre of mass of the patient, finds its position and automatically places a region of interest (ROI) in the liver, which is used to calculate the average SUV. The algorithm was validated on a population of 630 PET/CT scans coming from more than 60 different scanners. The SUV was also calculated by manually placing a large ROI in the liver.& para;& para;Results: LIDEA identified the liver with a 97.3% sensitivity with PET/CT images only and reached a 98.9% correct detection rate when using the co-registered CT scan to avoid liver misidentification in the right lung.& para;& para;The average liver SUV obtained with LIDEA was successfully validated against its manual assessment, with no systematic difference (0.11 +/- 0.36 SUV units) and a R-2 = 0.89 correlation coefficient.& para;& para;Conclusions: LIDEA proved to be a reliable tool to automatically identify and extract the average SUV of the liver in oncological whole-body PET/CT scans. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:47 / 52
页数:6
相关论文
共 50 条
  • [21] Artificial intelligence enables whole-body positron emission tomography scans with minimal radiation exposure
    Yan-Ran (Joyce) Wang
    Lucia Baratto
    K. Elizabeth Hawk
    Ashok J. Theruvath
    Allison Pribnow
    Avnesh S. Thakor
    Sergios Gatidis
    Rong Lu
    Santosh E. Gummidipundi
    Jordi Garcia-Diaz
    Daniel Rubin
    Heike E. Daldrup-Link
    European Journal of Nuclear Medicine and Molecular Imaging, 2021, 48 : 2771 - 2781
  • [22] Artificial intelligence enables whole-body positron emission tomography scans with minimal radiation exposure
    Wang, Yan-Ran
    Baratto, Lucia
    Hawk, K. Elizabeth
    Theruvath, Ashok J.
    Pribnow, Allison
    Thakor, Avnesh S.
    Gatidis, Sergios
    Lu, Rong
    Gummidipundi, Santosh E.
    Garcia-Diaz, Jordi
    Rubin, Daniel
    Daldrup-Link, Heike E.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2021, 48 (09) : 2771 - 2781
  • [23] Results of 188 whole-body fluorodeoxyglucose positron emission tomography scans in 137 patients with sarcoidosis
    Teirtein, Alvin S.
    Machac, Josef
    Almeida, Orlandino
    Lu, Ping
    Padilla, Maria L.
    Iannuzzi, Michael C.
    CHEST, 2007, 132 (06) : 1949 - 1953
  • [24] Frequency and etiology of solitary hot spots in the pelvis at whole-body positron emission tomography/computed tomography imaging
    Khademi, Sara
    Westphalen, Antonio C.
    Webb, Emily M.
    Joe, Bonnie N.
    Badiee, Shiva
    Hawkins, Randy A.
    Coakley, Fergus V.
    CLINICAL IMAGING, 2009, 33 (01) : 44 - 48
  • [25] WHOLE-BODY POSITRON EMISSION TOMOGRAPHY IN BREAST-CANCER
    NITZSCHE, EU
    HOH, CK
    DALBOHM, NM
    GLASPY, JA
    PHELPS, ME
    MOSER, EA
    HAWKINS, RA
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1993, 158 (04): : 293 - 298
  • [26] Lean body mass correction of standardized uptake value in simultaneous whole-body positron emission tomography and magnetic resonance imaging
    Jochimsen, Thies H.
    Schulz, Jessica
    Busse, Harald
    Werner, Peter
    Schaudinn, Alexander
    Zeisig, Vilia
    Kurch, Lars
    Seese, Anita
    Barthel, Henryk
    Sattler, Bernhard
    Sabri, Osama
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (12): : 4651 - 4664
  • [27] Clinical value of whole body fluorine-18 fluorodeoxyglucose positron emission tomography/computed tomography in the detection of metastatic bladder cancer
    Yang, Zhongyi
    Pan, Lingling
    Cheng, Jingyi
    Hu, Silong
    Xu, Junyan
    Ye, Dingwei
    Zhang, Yingjian
    INTERNATIONAL JOURNAL OF UROLOGY, 2012, 19 (07) : 639 - 644
  • [28] The prognostic role of whole-body volumetric positron emission tomography/computed tomography parameters in treatment naive colorectal cancer patients with liver metastases
    Karaoglan, Huseyin
    Kepenek, Ferat
    Komek, Halil
    Kaplan, Ihsan
    Yeprem, Omer
    Kaya, Ridvan
    Guzel, Yunus
    Senses, Veysi
    Ipek, Fulya Kaya
    Can, Canan
    NUCLEAR MEDICINE COMMUNICATIONS, 2025, 46 (01) : 55 - 59
  • [29] Comparison of contrast-enhanced computed tomography and whole-body positron emission tomography for initial staging of Hodgkin disease
    Blum, MR
    Jeffrey, RB
    Krausz, Y
    Segall, GM
    RADIOLOGY, 1999, 213P : 421 - 421
  • [30] Whole body positron emission tomography/computed tomography staging of metastatic choroidal melanoma
    Kurli, M
    Reddy, S
    Tena, LB
    Pavlick, AC
    Finger, PT
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2005, 140 (02) : 193 - 199