Improved Focusing Method for 3-D Imaging using Row-Column-Addressed 2-D Arrays

被引:0
|
作者
Bouzari, Hamed [1 ]
Engholm, Mathias [2 ]
Stuart, Matthias Bo [1 ]
Thomsen, Erik Vilain [2 ]
Jensen, Jorgen Arendt [1 ]
机构
[1] Tech Univ Denmark, Dept Elect Engn, Ctr Fast Ultrasound Imaging, Bldg 349, DK-2800 Lyngby, Denmark
[2] Tech Univ Denmark, Dept Micro & Nanotechnol, Bldg 344, DK-2800 Lyngby, Denmark
关键词
TRANSDUCER; DESIGN; SYSTEM;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A row-column-addressed (RCA) 2-D array can be interpreted as two orthogonal 1-D arrays. By transmitting with row elements and receiving the echoes through column elements or vice versa, a rectilinear volume in front of the array can be beamformed. Since the transmit and receive 1-D arrays are orthogonal to each other, only one-way focusing is possible in each transmit or receive plane. For applications, where the scatterers are sparse, e.g., in micro-bubble tracking, this study suggests to multiply the envelope data received by the row elements when transmitting with columns as well as the data received by the column elements when transmitting with rows, to improve the focusing. In this way, at each point a two-way focused profile in both transmit and receive directions can be produced. This paper investigates the performance of the new focusing scheme based on simulations and phantom measurements with a PZT lambda/2-pitch 3MHz 62+62 RCA 2-D transducer probe. A synthetic aperture imaging sequence with single element transmissions at a time, is designed for imaging down to 14 cm at a volume rate of 44 Hz.
引用
收藏
页数:4
相关论文
共 50 条
  • [21] A 256 x 256 2-D Array Transducer with Row-Column Addressing for 3-D Rectilinear Imaging
    Seo, Chi Hyung
    Yen, Jesse T.
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2009, 56 (04) : 837 - 847
  • [22] Hybrid Volume Beamforming for 3-D Ultrasound Imaging using 2-D CMUT Arrays
    Kim, Bae-Hyung
    Song, Tai-Kyong
    Yoo, Yangmo
    Chang, Jin Ho
    Lee, Seunghun
    Kim, Youngil
    Cho, Kyungil
    Song, Jongkeun
    [J]. 2012 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2012, : 2246 - 2249
  • [23] Experimental 3-D Ultrasound Imaging with 2-D Sparse Arrays using Focused and Diverging Waves
    Emmanuel Roux
    François Varray
    Lorena Petrusca
    Christian Cachard
    Piero Tortoli
    Hervé Liebgott
    [J]. Scientific Reports, 8
  • [24] Experimental 3-D Ultrasound Imaging with 2-D Sparse Arrays using Focused and Diverging Waves
    Roux, Emmanuel
    Varray, Francois
    Petrusca, Lorena
    Cachard, Christian
    Tortoli, Piero
    Liebgott, Herve
    [J]. SCIENTIFIC REPORTS, 2018, 8
  • [25] Coded Excitation with Unfocused Plane Waves for 3D Imaging Using a 2D Row Column Addressed Array
    Guezzi, Nizar
    Seong, Hyojin
    Yu, Jaesok
    [J]. 2022 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IEEE IUS), 2022,
  • [26] Finite element simulation and modeling of 2-D arrays for 3-D ultrasonic imaging
    McKeighen, R
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2001, 48 (05) : 1395 - 1405
  • [27] Sparse 2-D arrays for 3-D phased array imaging - Experimental validation
    Austeng, A
    Holm, S
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2002, 49 (08) : 1087 - 1093
  • [28] Sparse 2-D Arrays for 3-D phased array imaging - Design methods
    Austeng, A
    Holm, S
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2002, 49 (08) : 1073 - 1086
  • [29] 3-D companding using linear arrays for improved strain imaging
    Insana, MF
    Chaturvedi, P
    Hall, TJ
    Bilgen, M
    [J]. 1997 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1 & 2, 1997, : 1435 - 1438
  • [30] 3-D elasticity imaging with a 2-D array
    Fisher, T.
    Hall, T.
    Panda, S.
    Jiang, J.
    Resnick, I.
    Barnes, S.
    [J]. MEDICAL PHYSICS, 2007, 34 (06) : 2366 - 2366