3-D elasticity imaging with a 2-D array

被引:0
|
作者
Fisher, T.
Hall, T.
Panda, S.
Jiang, J.
Resnick, I.
Barnes, S.
机构
[1] Univ Wisconsin, Madison, WI USA
[2] Siemens Med Solut USA, Mountain View, CA USA
关键词
D O I
10.1118/1.2760499
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Assess the performance of various motion tracking strategies applied to a 3‐D RF echo data set from an oil‐in‐gelatin phantom with spherical targets for a multi‐step deformation totaling about 15% axial strain. Discuss the prospects and preliminary experience of in vivo motion tracking. Method and Materials: A prototype 9‐MHz 2‐D CMUT array connected to a Siemens SONOLINE Antares was used to acquire RF echo data from a 100‐mm × 100‐mm × 70‐mm oil‐in‐gelatin phantom containing a 10‐mm diameter spherical inclusion that has a 5:1 elastic contrast with the background. This CMUT array images like a 1‐D linear array in generating a 2‐D image in the azimuthal plane, and it acquires a 3‐D volume by electronically stepping the 2‐D imaging plane in the elevational direction. A series of controlled compressions of 1.5–2% axial strain were applied. Phantom motion was tracked with off‐line data processing using different approaches including 2‐D, 2.5‐D and 3‐D axial guidance tracking. The method that performed the best was applied to a 3‐D in vivo data set obtained with the same transducer. Results: The contrast to noise ratios (CNR) and the cross correlation between the motion‐compensated RF and the reference RF for the four motion tracking approaches were used as metrics of performance. The CNR increased with increasingly sophisticated motion tracking with 3‐D axial guidance performing the best. The same trend was observed with the normalized cross correlation. Tracking in vivo data has proved more difficult. Conclusions: These results demonstrate the improvement in motion tracking available through 3‐D tracking. This work also demonstrates that volume data acquisition allows accurate motion tracking and axial strain image formation for an entire target (within the field of view). Volume data acquisition with 2‐D arrays will provide a major advancement in the capabilities of elasticity imaging systems. © 2007, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2366 / 2366
页数:1
相关论文
共 50 条
  • [1] VOLUMETRIC ELASTICITY IMAGING WITH A 2-D CMUT ARRAY
    Fisher, Ted G.
    Hall, Timothy J.
    Panda, Satchi
    Richards, Michael S.
    Barbone, Paul E.
    Jiang, Jingfeng
    Resnick, Jeff
    Barnes, Steve
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2010, 36 (06): : 978 - 990
  • [2] Theoretical assessment of a crossed electrode 2-D array for 3-D imaging
    Morton, CE
    Lockwood, GR
    [J]. 2003 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1 AND 2, 2003, : 968 - 971
  • [3] Sparse 2-D Arrays for 3-D phased array imaging - Design methods
    Austeng, A
    Holm, S
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2002, 49 (08) : 1073 - 1086
  • [4] ADS-Based Array Design for 2-D and 3-D Ultrasound Imaging
    Oliveri, Giacomo
    Massa, Andrea
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2010, 57 (07) : 1568 - 1582
  • [5] Sparse 2-D arrays for 3-D phased array imaging - Experimental validation
    Austeng, A
    Holm, S
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2002, 49 (08) : 1087 - 1093
  • [6] 3-D Super-Resolution Ultrasound Imaging With a 2-D Sparse Array
    Harput, Sevan
    Tortoli, Piero
    Eckersley, Robert J.
    Dunsby, Chris
    Tang, Meng-Xing
    Christensen-Jeffries, Kirsten
    Ramalli, Alessandro
    Brown, Jemma
    Zhu, Jiaqi
    Zhang, Ge
    Leow, Chee Hau
    Toulemonde, Matthieu
    Boni, Enrico
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2020, 67 (02) : 269 - 277
  • [7] Minimally Redundant 2-D Array Designs for 3-D Medical Ultrasound Imaging
    Karaman, Mustafa
    Wygant, Ira O.
    Oralkan, Oemer
    Khuri-Yakub, Butrus T.
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2009, 28 (07) : 1051 - 1061
  • [8] 3-D/2-D registration by integrating 2-D information in 3-D
    Tomazevic, D
    Likar, B
    Pernus, F
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2006, 25 (01) : 17 - 27
  • [9] Development of a 2-D Array Ultrasonic Transducer for 3-D Imaging of Objects Immersed in Water
    Rodrigues, Estevio Patricio
    De Oliveira, Timoteo Francisco
    Matuda, Marcelo Yassunori
    Buiochi, Flavio
    [J]. SENSORS, 2021, 21 (10)
  • [10] Wideband 2-D Array Design Optimization With Fabrication Constraints for 3-D US Imaging
    Roux, Emmanuel
    Ramalli, Alessandro
    Liebgott, Herve
    Cachard, Christian
    Robini, Marc C.
    Tortoli, Piero
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2017, 64 (01) : 108 - 125