A 256 x 256 2-D Array Transducer with Row-Column Addressing for 3-D Rectilinear Imaging

被引:81
|
作者
Seo, Chi Hyung [1 ]
Yen, Jesse T. [2 ]
机构
[1] Univ Washington, Dept Bioengn, Seattle, WA 98195 USA
[2] Univ So Calif, Dept Biomed Engn, Los Angeles, CA 90089 USA
关键词
3-DIMENSIONAL ULTRASOUND; BREAST;
D O I
10.1109/TUFFC.2009.1107
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
We present simulation and experimental results from a 5-MHz, 256 x 256 2-D (65536 elements, 38.4 x 38.4 mm) 2-D array transducer with row-column addressing. The main benefits of this design are a reduced number of interconnects, a modified transmit/receive switching scheme with a simple diode circuit, and an ability to perform volumetric imaging of targets near the transducer with transmit beamforming in azimuth and receive beamforming in elevation. The final dimensions of the transducer were 38.4 mm x 38.4 rum x 300 mu m. After a row-column transducer was prototyped, the series resonance impedance was 104 Omega at 5.4 MHz. The measured -6 dB fractional bandwidth was 53% with a center frequency of 5.3 MHz. The SNR at the transmit focus was measured to be 30 dB. At 5 MHz, the average nearest neighbor crosstalk was -25 dB. In this paper, we present 3-D images of both 5 pairs of nylon wires embedded in a clear gelatin phantom and an 8 mm diameter cylindrical anechoic cyst phantom acquired from a 256 x 256 2-D array transducer made from a 1-3 composite. We display the azimuth and elevation B-scans as well as the C-scan for each image. The cross-section of the wires is visible in the azimuth B-scan, and the long axes can be seen in the elevation B-scan and C-scans. The pair of wires with 1-mm axial separation is discernible in the elevational B-scan. When a single wire from the wire target phantom was used, the measured lateral beamwidth was 0.68 mm and 0.70 mm at 30 mm depth in transmit beamforming and receive beamforming, respectively, compared with the simulated beamwidth of 0.55 mm. The cross-section of the cyst is visible in the azimuth B-scan whereas the long axes can be seen as a rectangle in the elevation B-scan and C-scans.
引用
收藏
页码:837 / 847
页数:11
相关论文
共 50 条
  • [1] 256x256 2-D array transducer with row-column addressing for 3-D imaging
    Seo, Chi Hyang
    Yen, Jesse T.
    [J]. 2007 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1-6, 2007, : 2381 - 2384
  • [2] Recent results using a 256 x 256 2-D array transducer for 3-D Rectilinear Imaging
    Seo, Chi Hyung
    Yen, Jesse T.
    [J]. 2008 IEEE ULTRASONICS SYMPOSIUM, VOLS 1-4 AND APPENDIX, 2008, : 1146 - 1149
  • [3] 64 X 64 2-D array transducer with row-column addressing
    Seo, Chi Hyting
    Yen, Jesse T.
    [J]. 2006 IEEE ULTRASONICS SYMPOSIUM, VOLS 1-5, PROCEEDINGS, 2006, : 74 - 77
  • [4] 3-D Ultrasound Imaging Performance of a Row-Column Addressed 2-D Array Transducer: A Measurement Study
    Rasmussen, Morten Fischer
    Jensen, Jorgen Arendt
    [J]. 2013 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2013, : 1452 - 1455
  • [5] The Design and Analysis of Split Row-Column Addressing Array for 2-D Transducer
    Li, Xu
    Jia, Yanping
    Ding, Mingyue
    Ming Yuchi
    [J]. SENSORS, 2016, 16 (10)
  • [6] The design of split row-column addressing array for 2D transducer
    YanpingJia
    LiushuaiLv
    Ding, Mingyue
    Yuchi, Ming
    [J]. MEDICAL IMAGING 2014: ULTRASONIC IMAGING AND TOMOGRAPHY, 2014, 9040
  • [7] 3-D Spatial Compounding Using a Row-Column Array
    Awad, Samer I.
    Yen, Jesse T.
    [J]. ULTRASONIC IMAGING, 2009, 31 (02) : 120 - 130
  • [8] 3D ultrasound imaging performance of a row-column addressed 2D array transducer: a simulation study
    Rasmussen, Morten Fischer
    Jensen, Jorgen Arendt
    [J]. MEDICAL IMAGING 2013: ULTRASONIC IMAGING, TOMOGRAPHY, AND THERAPY, 2013, 8675
  • [9] Acoustical cross-talk in row-column addressed 2-D transducer arrays for ultrasound imaging
    Christiansen, Thomas Lehrmann
    Jensen, Jorgen Arendt
    Thomsen, Erik Vilain
    [J]. ULTRASONICS, 2015, 63 : 174 - 178
  • [10] A Row-Column (RC) Addressed 2-D Capacitive Micromachined Ultrasonic Transducer (CMUT) Array on a Glass Substrate
    Sanders, Jean L.
    Biliroglu, Ali Onder
    Wu, Xun
    Adelegan, Oluwafemi J.
    Yamaner, Feysel Yalcin
    Oralkan, Omer
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2021, 68 (03) : 767 - 776