3D ultrasound imaging performance of a row-column addressed 2D array transducer: a simulation study

被引:16
|
作者
Rasmussen, Morten Fischer [1 ]
Jensen, Jorgen Arendt [1 ]
机构
[1] Tech Univ Denmark, Dept Elect Engn, Ctr Fast Ultrasound Imaging, DK-2800 Lyngby, Denmark
关键词
row-column addressing; beamforming; low channel count 3D imaging; 2D array transducer; synthetic aperture imaging; medical ultrasound; DESIGN; SYSTEM;
D O I
10.1117/12.2007083
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
This paper compares the imaging performance of a 128+128 element row-column addressed array with a fully addressed 16x16 2D array. The comparison is made via simulations of the point spread function with Field II. Both arrays have lambda-pitch, a center frequency of 3.5 MHz and use 256 active elements. The row-column addressed array uses 128 transmit channels and 128 receive channels, whereas the fully addressed array uses 256 channels in both transmit and receive. The large size of the emulated row and column elements in the row-column addressed array causes ghost echoes to appear. The ghost echoes are shown to be suppressed when the sub-elements within each of the emulated row and column elements are apodized. The maximum ghost intensity is suppressed by 22.2 dB compared to using no apodization. With apodization applied, the full-width-at-half-maximum in the lateral direction for the fully addressed array is 2.81 mm, and 1.01 mm for the row-column addressed array. This shows that the detail resolution can be more than doubled using the row-column addressed array instead of the fully addressed array. The row column addressed array achieves a R-20 dB cystic resolution of 0.76mm, compared to 3.16 mm for the fully addressed array. The signicantly smaller R-20 dB-value for the row-column addressed array indicates that it can achieve a much higher contrast resolution than the fully addressed array.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] 3-D Ultrasound Imaging Performance of a Row-Column Addressed 2-D Array Transducer: A Measurement Study
    Rasmussen, Morten Fischer
    Jensen, Jorgen Arendt
    [J]. 2013 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2013, : 1452 - 1455
  • [2] The design of split row-column addressing array for 2D transducer
    YanpingJia
    LiushuaiLv
    Ding, Mingyue
    Yuchi, Ming
    [J]. MEDICAL IMAGING 2014: ULTRASONIC IMAGING AND TOMOGRAPHY, 2014, 9040
  • [3] Curved Toroidal Row Column Addressed Transducer for 3D Ultrafast Ultrasound Imaging
    Caudoux, Manon
    Demeulenaere, Oscar
    Poree, Jonathan
    Sauvage, Jack
    Mateo, Philippe
    Ghaleh, Bijan
    Flesch, Martin
    Ferin, Guillaume
    Tanter, Mickael
    Deffieux, Thomas
    Papadacci, Clement
    Pernot, Mathieu
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2024, 43 (09) : 3279 - 3291
  • [4] Acoustical cross-talk in row-column addressed 2-D transducer arrays for ultrasound imaging
    Christiansen, Thomas Lehrmann
    Jensen, Jorgen Arendt
    Thomsen, Erik Vilain
    [J]. ULTRASONICS, 2015, 63 : 174 - 178
  • [5] 3D Volumetric Tensor Velocity Imaging with Low Computational Complexity Using a Row-Column Addressed Array
    Chetverikova, Kseniya
    Jensen, Jorgen Arendt
    Traberg, Marie Sand
    Stuart, Matthias Bo
    [J]. APPLIED SCIENCES-BASEL, 2021, 11 (12):
  • [6] Coded Excitation with Unfocused Plane Waves for 3D Imaging Using a 2D Row Column Addressed Array
    Guezzi, Nizar
    Seong, Hyojin
    Yu, Jaesok
    [J]. 2022 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IEEE IUS), 2022,
  • [7] A Row-Column (RC) Addressed 2D Capacitive Micromachined Ultrasonic Transducer (CMUT) Array on a Glass Substrate: Preliminary Results
    Sanders, Jean L.
    Wu, Xun
    Adelegan, Oluwafemi J.
    Mahmud, Marzana M.
    Yamaner, F. Yalcin
    Gallippi, Caterina M.
    Oralkan, Omer
    [J]. 2018 40TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2018, : 3468 - 3471
  • [8] Characterization of Low-Voltage Row-Column Addressed CMUTs for 3D Imaging Applications
    Merrien, Tony
    Boulme, Audren
    Chatain, Pascal
    Certon, Dominique
    [J]. 2022 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IEEE IUS), 2022,
  • [9] 256x256 2-D array transducer with row-column addressing for 3-D imaging
    Seo, Chi Hyang
    Yen, Jesse T.
    [J]. 2007 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1-6, 2007, : 2381 - 2384
  • [10] A 256 x 256 2-D Array Transducer with Row-Column Addressing for 3-D Rectilinear Imaging
    Seo, Chi Hyung
    Yen, Jesse T.
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2009, 56 (04) : 837 - 847