Effect of Dislodging Forces on Mandibular Implant Attachment-Retained Overdenture

被引:16
|
作者
ElKerdawy, Maha Wagdy [1 ]
Radi, Iman Abdel Wahab [1 ]
机构
[1] Cairo Univ, Dept Removable Prosthodont, Fac Oral & Dent Med, Cairo, Egypt
关键词
overdenture; implants; attachments; retention; strain gauge; BAR ATTACHMENTS; LOAD-TRANSFER; BALL; MAGNET; RETENTION; DESIGN; STRAIN;
D O I
10.1097/ID.0b013e318211fe1b
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: The goal of this in vitro study was to evaluate stress patterns and retention of ball and socket and 2 telescopic attachments of different convergence angles retaining an implant-supported overdenture prosthesis. Materials and Methods: This study was carried out on an edentulous mandibular acrylic resin educational model. Four dummy implants, 3.5 mm in diameter and 11 mm in length, were installed in the interforaminal area. The framework of the overdenture was cast. Eight strain gauges were attached to the buccal and distal surfaces of all implants. The experiment was divided into 3 phases: 1 with the ball and socket attachment and the other with the angle 4 degrees followed by angle 6 degrees telescopic retainers. Once retention and stress analysis studies were completed for the ball attachments, they were replaced by the telescopic retainers. The universal testing machine was used to measure the retentive forces of the studied attachments. A 4-channel strain-meter was used to record the microstrains transmitted to each strain gauge while the machine was adjusted to move in a tensile mode. Results: Statistical analysis showed the highest significant retention values for the ball and socket followed by telescope angle 4 degrees and finally angle 6 degrees. The same ranking was found on comparing the mean strains developed at the implants. Conclusion: This study has demonstrated that implant overdenture attachment design and dislodging forces may significantly influence stress/strain magnitude around implants; the higher the retention (resistance to dislodging forces) of the attachments the more the transferred stresses. (Implant Dent 2011;20:246-254)
引用
收藏
页码:246 / +
页数:9
相关论文
共 50 条
  • [21] Comparison of detachment forces of two implant overdenture attachment types: Effect of detachment speed
    Jefferies, Steven R.
    Boston, Daniel W.
    Damrow, Michael P.
    Galbraith, Colin T.
    AMERICAN JOURNAL OF DENTISTRY, 2008, 21 (04): : 244 - 250
  • [22] Effect of Ball and Bar Attachment Type on Patient Satisfaction Using Two-Implant-Retained Mandibular Overdenture: A Crossover Randomized Clinical Trial
    Saee Deshpande
    Anuj Chandak
    Usha Radke
    Hienna Mahalle
    Pravinkumar G. Patil
    Journal of Maxillofacial and Oral Surgery, 2022, 21 : 1175 - 1179
  • [23] The Influence of Momentary Retention Forces on Patient Satisfaction and Quality of Life of Two-Implant-Retained Mandibular Overdenture Wearers
    Geckili, Onur
    Cilingir, Altug
    Erdogan, Ozge
    Kesoglu, Aysun Coskun
    Bilmenoglu, Caglar
    Ozdiler, Arda
    Bilhan, Hakan
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2015, 30 (02) : 397 - 402
  • [24] Fabrication of a mandibular implant-retained overdenture using an existing subperiosteal implant: A clinical report
    Arshad, Mahnaz
    Khoramshahi, Nourin
    Shirani, Gholamreza
    CLINICAL CASE REPORTS, 2024, 12 (04):
  • [25] Mandibular implant-retained overdenture: A clinical trial of two anchorage systems
    Menicucci, G
    Lorenzetti, M
    Pera, P
    Preti, G
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 1998, 13 (06) : 851 - 856
  • [26] Bite forces with mandibular implant-retained overdentures
    Fontijn-Tekamp, FA
    Slagter, AP
    van't Hof, MA
    Geertman, ME
    Kalk, W
    JOURNAL OF DENTAL RESEARCH, 1998, 77 (10) : 1832 - 1839
  • [27] Retention of Different Attachment Systems for Digitally Designed Mandibular Implant Overdenture
    Abdelaziz, Medhat Sameh
    Fawzy, Aya Mohamed
    Ghali, Rami Maher
    Nassar, Hossam, I
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2023, 32 (02): : 162 - 169
  • [28] Biomechanical rationale for a single implant-retained mandibular overdenture:: an in vitro study
    Maeda, Yoshinobu
    Horisaka, Mitsuhiro
    Yagi, Kaztomo
    CLINICAL ORAL IMPLANTS RESEARCH, 2008, 19 (03) : 271 - 275
  • [29] Direct procedure for connecting a mandibular implant-retained overdenture with ball attachments
    Taddei, C
    Metz, M
    Waltman, E
    Etienne, O
    JOURNAL OF PROSTHETIC DENTISTRY, 2004, 92 (04): : 403 - 404
  • [30] Patient-Based and Clinical Outcomes of Implant Telescopic Attachment-Retained Mandibular Overdentures: A 1-Year Longitudinal Prospective Study
    Yunus, Norsiah
    Saub, Roslan
    Ali, Tara Bai Taiyeb
    Salleh, Nosizana Mohd
    Baig, Mirza Rustum
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2014, 29 (05) : 1149 - 1156