Effect of Dislodging Forces on Mandibular Implant Attachment-Retained Overdenture

被引:16
|
作者
ElKerdawy, Maha Wagdy [1 ]
Radi, Iman Abdel Wahab [1 ]
机构
[1] Cairo Univ, Dept Removable Prosthodont, Fac Oral & Dent Med, Cairo, Egypt
关键词
overdenture; implants; attachments; retention; strain gauge; BAR ATTACHMENTS; LOAD-TRANSFER; BALL; MAGNET; RETENTION; DESIGN; STRAIN;
D O I
10.1097/ID.0b013e318211fe1b
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: The goal of this in vitro study was to evaluate stress patterns and retention of ball and socket and 2 telescopic attachments of different convergence angles retaining an implant-supported overdenture prosthesis. Materials and Methods: This study was carried out on an edentulous mandibular acrylic resin educational model. Four dummy implants, 3.5 mm in diameter and 11 mm in length, were installed in the interforaminal area. The framework of the overdenture was cast. Eight strain gauges were attached to the buccal and distal surfaces of all implants. The experiment was divided into 3 phases: 1 with the ball and socket attachment and the other with the angle 4 degrees followed by angle 6 degrees telescopic retainers. Once retention and stress analysis studies were completed for the ball attachments, they were replaced by the telescopic retainers. The universal testing machine was used to measure the retentive forces of the studied attachments. A 4-channel strain-meter was used to record the microstrains transmitted to each strain gauge while the machine was adjusted to move in a tensile mode. Results: Statistical analysis showed the highest significant retention values for the ball and socket followed by telescope angle 4 degrees and finally angle 6 degrees. The same ranking was found on comparing the mean strains developed at the implants. Conclusion: This study has demonstrated that implant overdenture attachment design and dislodging forces may significantly influence stress/strain magnitude around implants; the higher the retention (resistance to dislodging forces) of the attachments the more the transferred stresses. (Implant Dent 2011;20:246-254)
引用
收藏
页码:246 / +
页数:9
相关论文
共 50 条
  • [31] Effect of the Number of Supporting Implants on Mandibular Photoelastic Models with Different Implant-Retained Overdenture Designs
    Celik, Gozde
    Uludag, Bulent
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2014, 23 (05): : 374 - 380
  • [32] Influence of Denture Cleansers on the Retention Loss of Attachment Systems Retained Implant Overdenture
    AlRumaih, Hamad S. S.
    Albarrak, Alhanouf A. A.
    AlMedaires, Muneera
    Alsulaiman, Ahmed A. A.
    Baba, Nadim Z. Z.
    Alshahrani, Faris A. A.
    Alqarawi, Firas K. K.
    Al-Dulaijan, Yousif A. A.
    Alzoubi, Fawaz
    Alhumaidan, Abdulkareem A. A.
    Gad, Mohammed M. M.
    INTERNATIONAL JOURNAL OF BIOMATERIALS, 2023, 2023
  • [33] ATTACHMENT OF CLIPS IN A BAR-RETAINED MAXILLARY IMPLANT OVERDENTURE: A CLINICAL REPORT
    Slot, Wim
    Raghoebar, Gerry M.
    van Dijk, Gerrit
    Meijer, Henny J. A.
    JOURNAL OF PROSTHETIC DENTISTRY, 2012, 107 (06): : 353 - 357
  • [34] Evaluation of the retention characteristics of various stud attachment systems for implant retained overdenture
    Gonuldas, Fehmi
    Tokar, Emre
    Ozturk, Caner
    ACTA OF BIOENGINEERING AND BIOMECHANICS, 2018, 20 (04) : 135 - 141
  • [35] Immediate Loading of Two Implants Supporting a Magnet Attachment-Retained Overdenture: One-Year Clinical Study
    Pae, Ahran
    Kim, Jang-Wook
    Kwon, Kung-Rock
    IMPLANT DENTISTRY, 2010, 19 (05) : 428 - 436
  • [36] Effect of mandibular bone atrophy on maxillary and mandibular bone remodeling and quality of life with an implant-retained mandibular overdenture after 3 years
    Schuster, Alessandra Julie
    Possebon, Anna Paula da Rosa
    Schinestsck, Andre Ribeiro
    Chagas-Junior, Otacilio Luiz
    Faot, Fernanda
    JOURNAL OF PROSTHETIC DENTISTRY, 2023, 130 (02): : 220 - 228
  • [37] The influence of attachment systems on implant-retained mandibular overdentures
    Naert, I
    IMPLANT OVERDENTURES: THE STANDARD OF CARE FOR EDENTULOUS PATIENTS, 2003, : 99 - 109
  • [38] Effect of Distal Implant Inclination on Dislodging Forces of Different Locator Attachments Used for Mandibular Overdentures: An In Vitro Study
    ELsyad, Moustafa Abdou
    Emera, Radwa Mohsen
    Ashmawy, Tarek Mohy
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2019, 28 (02): : E666 - E674
  • [39] Two-implant retained mandibular overdenture: a viable alternative in total edentulism rehabilitation
    Berardini, M.
    Di Iorio, E.
    DENTAL CADMOS, 2015, 83 (03) : 138 - +
  • [40] Correcting a nonparallel implant abutment for a mandibular overdenture retained by two implants: A clinical report
    Khadivi, V
    JOURNAL OF PROSTHETIC DENTISTRY, 2004, 92 (03): : 216 - 219