Effect of Dislodging Forces on Mandibular Implant Attachment-Retained Overdenture

被引:16
|
作者
ElKerdawy, Maha Wagdy [1 ]
Radi, Iman Abdel Wahab [1 ]
机构
[1] Cairo Univ, Dept Removable Prosthodont, Fac Oral & Dent Med, Cairo, Egypt
关键词
overdenture; implants; attachments; retention; strain gauge; BAR ATTACHMENTS; LOAD-TRANSFER; BALL; MAGNET; RETENTION; DESIGN; STRAIN;
D O I
10.1097/ID.0b013e318211fe1b
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: The goal of this in vitro study was to evaluate stress patterns and retention of ball and socket and 2 telescopic attachments of different convergence angles retaining an implant-supported overdenture prosthesis. Materials and Methods: This study was carried out on an edentulous mandibular acrylic resin educational model. Four dummy implants, 3.5 mm in diameter and 11 mm in length, were installed in the interforaminal area. The framework of the overdenture was cast. Eight strain gauges were attached to the buccal and distal surfaces of all implants. The experiment was divided into 3 phases: 1 with the ball and socket attachment and the other with the angle 4 degrees followed by angle 6 degrees telescopic retainers. Once retention and stress analysis studies were completed for the ball attachments, they were replaced by the telescopic retainers. The universal testing machine was used to measure the retentive forces of the studied attachments. A 4-channel strain-meter was used to record the microstrains transmitted to each strain gauge while the machine was adjusted to move in a tensile mode. Results: Statistical analysis showed the highest significant retention values for the ball and socket followed by telescope angle 4 degrees and finally angle 6 degrees. The same ranking was found on comparing the mean strains developed at the implants. Conclusion: This study has demonstrated that implant overdenture attachment design and dislodging forces may significantly influence stress/strain magnitude around implants; the higher the retention (resistance to dislodging forces) of the attachments the more the transferred stresses. (Implant Dent 2011;20:246-254)
引用
收藏
页码:246 / +
页数:9
相关论文
共 50 条
  • [1] POSTPLACEMENT BITING FORCE IN ATTACHMENT-RETAINED OVERDENTURE WEARERS
    SPOSETTI, VJ
    ALDERSON, TH
    GIBBS, CH
    JOURNAL OF DENTAL RESEARCH, 1986, 65 : 255 - 255
  • [2] Maximum dislodging forces of implant overdenture stud attachments
    Petropoulos, VC
    Smith, W
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2002, 17 (04) : 526 - 535
  • [3] Effects of Implant Angulations and Attachment Configurations on the Retentive Forces of Locator Attachment-Retained Overdentures
    Uludag, Bulent
    Polat, Serdar
    Sahin, Volkan
    Comut, Ali Alper
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2014, 29 (05) : 1053 - 1057
  • [4] The effect of attachment type and implant number on satisfaction and quality of life of mandibular implant-retained overdenture wearers
    Mumcu, Emre
    Bilhan, Hakan
    Geckili, Onur
    GERODONTOLOGY, 2012, 29 (02) : E618 - E623
  • [5] Immediate loading of two implants supporting a ball attachment-retained mandibular overdenture: A prospective clinical study
    Marzola, Riccardo
    Scotti, Roberto
    Fazi, Giovanni
    Schincaglia, Gian Pietro
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2007, 9 (03) : 136 - 143
  • [6] MANDIBULAR IMPLANT-SUPPORTED PRECISION ATTACHMENT-RETAINED FIXED PROSTHESIS: CASE REPORT
    Aksan, Muhammet Emin
    Bulut, Ali Can
    ANNALS OF DENTAL SPECIALTY, 2020, 8 (01): : 67 - 71
  • [7] Effect of LOCATOR attachments with different retentive forces on the stability of 2-implant-retained mandibular overdenture
    Liu, Wei
    Zhang, Xin
    Qing, Hai
    Wang, Jian
    JOURNAL OF PROSTHETIC DENTISTRY, 2020, 124 (02): : 224 - 229
  • [8] An Alternative Incorporation Technique for Minimizing Complications in Attachment-Retained Implant Mandibular Overdentures: Technical Report
    Sipahi, Cumhur
    Ezmek, Bahadir
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2020, 29 (09): : 814 - 817
  • [9] METAL-REINFORCED SINGLE IMPLANT MANDIBULAR OVERDENTURE RETAINED BY AN ATTACHMENT: A CLINICAL REPORT
    Grageda, Edgar
    Rieck, Bastian
    JOURNAL OF PROSTHETIC DENTISTRY, 2014, 111 (01): : 16 - 19
  • [10] AN IMPLANT-SUPPORTED, COBALT-CHROMIUM MILLED BAR AND NONFLANGED ATTACHMENT-RETAINED OVERDENTURE TO REHABILITATE THE EDENTULOUS MANDIBLE
    Lowe, Leonard G.
    Shcherbukhin, Vladimir M.
    JOURNAL OF PROSTHETIC DENTISTRY, 2009, 102 (01): : 46 - 51