Retention of Different Attachment Systems for Digitally Designed Mandibular Implant Overdenture

被引:9
|
作者
Abdelaziz, Medhat Sameh [1 ]
Fawzy, Aya Mohamed [1 ]
Ghali, Rami Maher [2 ]
Nassar, Hossam, I [1 ]
机构
[1] Future Univ Egypt, Fac Oral & Dent Med, Dept Prosthodont, End 90 St, Cairo 11835, Egypt
[2] Ain Shams Univ, Fac Dent, Dept Prosthodont, Cairo, Egypt
关键词
attachments; dental implants; overdenture; retention; single digital-reinforced denture; FORCE; POLYETHERETHERKETONE; WEAR;
D O I
10.1111/jopr.13516
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose Primary retention and gradual loss of retention of different attachment systems are important key factors in proper attachment selection; however, studies on attachment retention show a wide range of retention values concerning the same attachment system. This in vitro study uses a novel approach that utilizes a digitally designed and 3D-printed reinforced overdenture, which has a digitally determined geometric center, in order to standardize results for future research and clinical work. This study aims to evaluate initial retention along with the gradual loss of retention at different time intervals between three types of stud attachments, retaining a digitally designed, reinforced mandibular overdenture after 5475 cycles simulating 5 years of attachment usage. Materials and Methods An epoxy model of an ACP Class I (American College of Prosthodontists) edentulous mandible was constructed. A fully computer-designed surgical guide was employed after virtual denture design to place two implants according to prosthetically driven implant placement protocol. A metal meshwork with tissue stops was designed digitally to reinforce the denture and to carry the geometric center. The meshwork was incorporated into the denture-intaglio surface, which was planned for attachment pickup. Forty-eight digitally designed and metal-reinforced 3D-printed dentures were divided into four groups (12 dentures for each group). Loss of retention was measured to compare two novel Locator attachments (12 pairs of Locator R-TX, 12 pairs of Locator F-TX medium and low retention, with 12 pairs of ball and socket). Each group was subjected to an insertion and removal fatigue test resembling 5 years of patient usage. Retention values were recorded using a universal testing machine. Results Locator F-TX medium and low retention showed loss of retention by 91.93% and 92.91%, after fatigue testing equivalent to 2 and 3 years of use, respectively. Ball and socket and Locator R-TX showed loss of retention by 19.87% and 26.31%, respectively, after fatigue testing equivalent to 5 years of use. Conclusions Locator R-TX attachment systems showed promising retention for implant overdentures compared to ball and socket attachments. The proposed digital technique of denture reinforcement is capable of standardizing results for research and clinical work.
引用
收藏
页码:162 / 169
页数:8
相关论文
共 50 条
  • [1] Retention of bar clip attachment for mandibular implant overdenture
    Nassar, Hossam, I
    Abdelaziz, Medhat Sameh
    [J]. BMC ORAL HEALTH, 2022, 22 (01)
  • [2] Retention of bar clip attachment for mandibular implant overdenture
    Hossam I. Nassar
    Medhat Sameh Abdelaziz
    [J]. BMC Oral Health, 22
  • [3] Stress analysis of mandibular two-implant overdenture with different attachment systems
    Takeshita, Shin
    Kanazawa, Manabu
    Minakuchi, Shunsuke
    [J]. DENTAL MATERIALS JOURNAL, 2011, 30 (06) : 928 - 934
  • [4] The Effect of Mini Dental Implant Number on Mandibular Overdenture Retention and Attachment Wear
    Alshenaiber, Rafif
    Barclay, Craig
    Silikas, Nick
    [J]. BIOMED RESEARCH INTERNATIONAL, 2023, 2023
  • [5] The influence of the number and the type of magnetic attachment on the retention of mandibular mini implant overdenture
    Lee, Eunjee
    Shin, Soo-Yeon
    [J]. JOURNAL OF ADVANCED PROSTHODONTICS, 2017, 9 (01): : 14 - 21
  • [6] Influence of attachment wear on retention of mandibular overdenture
    Rutkunas, V.
    Mizutani, H.
    Takahashi, H.
    [J]. JOURNAL OF ORAL REHABILITATION, 2007, 34 (01) : 41 - 51
  • [7] Photoelastic Stress Distribution Produced by Different Retention Systems for a Single-Implant Mandibular Overdenture
    Machado Nascimento, Joao Francisco
    Aguiar-Junior, Fabio Afranio
    Nogueira, Tulio Eduardo
    Silveira Rodrigues, Renata Cristina
    Leles, Claudio Rodrigues
    [J]. JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2015, 24 (07): : 538 - 542
  • [8] Influence of Denture Cleansers on the Retention Loss of Attachment Systems Retained Implant Overdenture
    AlRumaih, Hamad S. S.
    Albarrak, Alhanouf A. A.
    AlMedaires, Muneera
    Alsulaiman, Ahmed A. A.
    Baba, Nadim Z. Z.
    Alshahrani, Faris A. A.
    Alqarawi, Firas K. K.
    Al-Dulaijan, Yousif A. A.
    Alzoubi, Fawaz
    Alhumaidan, Abdulkareem A. A.
    Gad, Mohammed M. M.
    [J]. INTERNATIONAL JOURNAL OF BIOMATERIALS, 2023, 2023
  • [9] Effect of implant angulation and patrice on the retention of overdenture attachment systems: An in vitro study
    Frantz, Kristen
    Funkenbusch, Paul
    Feng, Changyong
    Tsigarida, Alexandra
    Chochlidakis, Konstantinos
    Lo Russo, Lucio
    Ercoli, Carlo
    [J]. JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2024, 33 (05): : 452 - 459
  • [10] Evaluation of the retention characteristics of various stud attachment systems for implant retained overdenture
    Gonuldas, Fehmi
    Tokar, Emre
    Ozturk, Caner
    [J]. ACTA OF BIOENGINEERING AND BIOMECHANICS, 2018, 20 (04) : 135 - 141