Retention of bar clip attachment for mandibular implant overdenture

被引:5
|
作者
Nassar, Hossam, I [1 ]
Abdelaziz, Medhat Sameh [1 ]
机构
[1] Future Univ Egypt, Fac Oral & Dent Med, Dept Prosthodont, Fifth Settlement,End 90 St, New Cairo, Egypt
关键词
Dental materials; Denture precision attachment; Dental implantation; Denture retention; Computer-aided design; SUPPORTED OVERDENTURE; FORCE; POLYETHERETHERKETONE; PEEK;
D O I
10.1186/s12903-022-02262-7
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives The aim of the present study was to evaluate the retention and loss of retention after fatigue testing at different time intervals between two types of bar clip materials (digitally designed PEEK bar clip and regular Nylon bar clip). Materials and methods An epoxy model was constructed for a completely edentulous mandible. Two implants were placed according to prosthetically driven implant placement by a computer-guided surgical stent. Bar clips were digitally designed, 3D printed, and pressed into Poly Ether Ether Ketone (PEEK). Pick up of PEEK and nylon clips was performed on the dentures fitting surface using self-cured acrylic resin. Each study group was subjected to an insertion and removal fatigue test simulating 3 years of patient usage. Retention values were recorded using the universal testing machine at initial retention and after 1, 2, and 3 years of simulated usage. For proper sample sizing, 24 models and dentures (12 for each group) were used. An independent sample t-test and repeated measures analysis of variance were used to compare the data. Results There were statistically significant differences in retention between the PEEK and nylon bar clips at the beginning of the experiment (p = 0.000*). But after 3 years of simulated use, there was no significant difference in retention between the test groups (p = 0.055, NS). After 3 years of simulated use, the retention of PEEK clips decreased by - 58.66% recording 17.37 +/- 1.07 N, while the retention of nylon clip increased by + 2.99% recording 16.56 +/- 0.88 N. Conclusion The digitally designed PEEK clip showed comparable retention results to the nylon clip after 3 years of simulated use.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Retention of bar clip attachment for mandibular implant overdenture
    Hossam I. Nassar
    Medhat Sameh Abdelaziz
    [J]. BMC Oral Health, 22
  • [2] Retention of Implant-Supported Overdenture With Bar/Clip and Stud Attachment Designs
    Savabi, Omid
    Nejatidanesh, Farahnaz
    Yordshahian, Forough
    [J]. JOURNAL OF ORAL IMPLANTOLOGY, 2013, 39 (02) : 140 - 147
  • [3] Retention of Different Attachment Systems for Digitally Designed Mandibular Implant Overdenture
    Abdelaziz, Medhat Sameh
    Fawzy, Aya Mohamed
    Ghali, Rami Maher
    Nassar, Hossam, I
    [J]. JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2023, 32 (02): : 162 - 169
  • [4] Stress analysis of mandibular implant overdenture with locator and bar/clip attachment: Comparative study with differences in the denture base length
    Yoo, Jin Suk
    Kwon, Kung-Rock
    Noh, Kwantae
    Lee, Hyeonjong
    Paek, Janghyun
    [J]. JOURNAL OF ADVANCED PROSTHODONTICS, 2017, 9 (03): : 143 - 151
  • [5] The Effect of Mini Dental Implant Number on Mandibular Overdenture Retention and Attachment Wear
    Alshenaiber, Rafif
    Barclay, Craig
    Silikas, Nick
    [J]. BIOMED RESEARCH INTERNATIONAL, 2023, 2023
  • [6] The influence of the number and the type of magnetic attachment on the retention of mandibular mini implant overdenture
    Lee, Eunjee
    Shin, Soo-Yeon
    [J]. JOURNAL OF ADVANCED PROSTHODONTICS, 2017, 9 (01): : 14 - 21
  • [7] Retention and patient satisfaction with bar-clip, ball and socket and kerator attachments in mandibular implant overdenture treatment: An in vivo study
    Varshney, Nitish
    Aggarwal, Sumit
    Kumar, Shalabh
    Singh, S. P.
    [J]. JOURNAL OF INDIAN PROSTHODONTIC SOCIETY, 2019, 19 (01): : 49 - 57
  • [8] Implant-supported overdenture with prefabricated bar attachment system in mandibular edentulous patient
    Ha, Seung-Ryong
    Kim, Sung-Hun
    Song, Seung-Il
    Hong, Seong-Tae
    Kim, Gy-Young
    [J]. JOURNAL OF ADVANCED PROSTHODONTICS, 2012, 4 (04): : 254 - 258
  • [9] Influence of attachment wear on retention of mandibular overdenture
    Rutkunas, V.
    Mizutani, H.
    Takahashi, H.
    [J]. JOURNAL OF ORAL REHABILITATION, 2007, 34 (01) : 41 - 51
  • [10] CLIP ATTACHMENT FOR THE MANDIBULAR STAPLE IMPLANT
    HURTADO, AJ
    MCGIVNEY, GP
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 1984, 52 (05): : 715 - 717