Probe calibration for freehand 3-D ultrasound

被引:86
|
作者
Lindseth, F [1 ]
Tangen, GA [1 ]
Lango, T [1 ]
Bang, J [1 ]
机构
[1] SINTEF, Unimed Ultrasound, N-7465 Trondheim, Norway
来源
ULTRASOUND IN MEDICINE AND BIOLOGY | 2003年 / 29卷 / 11期
关键词
utrasound probe calibration; freehand 3-D ultrasound reconstruction; ultrasound-based surgical navigation; image-guided therapy; phantom study; accuracy evaluation; automatic point detection; image processing;
D O I
10.1016/S0301-5629(03)01012-3
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Ultrasound (US) probe calibration establishes the rigid body transformation between the US image and a tracking device attached to the probe. This is an important requirement for correct 3-D reconstruction of freehand US images and, thus, for accurate surgical navigation based on US. In this study, we evaluated three methods for probe calibration, based on a single-point phantom, a wire-cross phantom requiring 2-D alignment and a wire phantom for freehand scanning. The processing of acquired data is fairly common to these methods and, to a great extent, based on automated procedures. The evaluation is based on quality measures in 2-D and 3-D reconstructed data. With each of the three methods, we calibrated a linear-array probe, a phased-array sector probe and an intraoperative probe. The freehand method performed best, with a 3-D navigation accuracy of 0.6 mm for one of the probes. This indicates that clinical accuracy in the order of I mm may be achieved in US-based surgical navigation.
引用
下载
收藏
页码:1607 / 1623
页数:17
相关论文
共 50 条
  • [11] Accuracy estimation in freehand ultrasound probe calibration
    Moghari, Mehdi H.
    Chen, Thomas K.
    Abolmaesumi, Purang
    MEDICAL IMAGING 2007: ULTRASONIC IMAGING AND SIGNAL PROCESSING, 2007, 6513
  • [12] Accurate calibration method for 3D freehand ultrasound probe using virtual plane
    De Lorenzo, Danilo
    Vaccarella, Alberto
    Khreis, Ghassan
    Moennich, Holger
    Ferrigno, Giancarlo
    De Momi, Elena
    MEDICAL PHYSICS, 2011, 38 (12) : 6710 - 6720
  • [13] Comparison of calibration methods for spatial tracking of a 3-D ultrasound probe
    Poon, TC
    Rohling, RN
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2005, 31 (08): : 1095 - 1108
  • [14] 3-D FREEHAND ULTRASOUND CALIBRATION USING A TISSUE-MIMICKING PHANTOM WITH PARALLEL WIRES
    Marcadent, Sandra
    Heches, Johann
    Favre, Julien
    Desseauve, David
    Thiran, Jean-Philippe
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2023, 49 (01): : 165 - 177
  • [15] Speckle classification for sensorless freehand 3-D ultrasound
    Hassenpflug, P
    Prager, RW
    Treece, GM
    Gee, AH
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2005, 31 (11): : 1499 - 1508
  • [16] FREEHAND 3-D ULTRASOUND IMAGING: A SYSTEMATIC REVIEW
    Mozaffari, Mohammad Hamed
    Lee, Won-Sook
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2017, 43 (10): : 2099 - 2124
  • [17] Volume measurement in sequential freehand 3-D ultrasound
    Treece, G
    Prager, R
    Gee, A
    Berman, L
    INFORMATION PROCESSING IN MEDICAL IMAGING, PROCEEDINGS, 1999, 1613 : 70 - 83
  • [18] High-definition freehand 3-D ultrasound
    Treece, GM
    Gee, AH
    Prager, RW
    Cash, CJC
    Berman, LH
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2003, 29 (04): : 529 - 546
  • [19] 3-D ultrasound probe calibration for computer-guided diagnosis and therapy
    Baumann, Michael
    Daanen, Vincent
    Leroy, Antoine
    Troccaz, Jocelyne
    COMPUTER VISION APPROACHES TO MEDICAL IMAGE ANALYSIS, 2006, 4241 : 248 - 259
  • [20] Body-centered visualisation for freehand 3-D ultrasound
    Tuomola, PM
    Gee, AH
    Prager, RW
    Berman, L
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2000, 26 (04): : 539 - 550