Probe calibration for freehand 3-D ultrasound

被引:86
|
作者
Lindseth, F [1 ]
Tangen, GA [1 ]
Lango, T [1 ]
Bang, J [1 ]
机构
[1] SINTEF, Unimed Ultrasound, N-7465 Trondheim, Norway
来源
ULTRASOUND IN MEDICINE AND BIOLOGY | 2003年 / 29卷 / 11期
关键词
utrasound probe calibration; freehand 3-D ultrasound reconstruction; ultrasound-based surgical navigation; image-guided therapy; phantom study; accuracy evaluation; automatic point detection; image processing;
D O I
10.1016/S0301-5629(03)01012-3
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Ultrasound (US) probe calibration establishes the rigid body transformation between the US image and a tracking device attached to the probe. This is an important requirement for correct 3-D reconstruction of freehand US images and, thus, for accurate surgical navigation based on US. In this study, we evaluated three methods for probe calibration, based on a single-point phantom, a wire-cross phantom requiring 2-D alignment and a wire phantom for freehand scanning. The processing of acquired data is fairly common to these methods and, to a great extent, based on automated procedures. The evaluation is based on quality measures in 2-D and 3-D reconstructed data. With each of the three methods, we calibrated a linear-array probe, a phased-array sector probe and an intraoperative probe. The freehand method performed best, with a 3-D navigation accuracy of 0.6 mm for one of the probes. This indicates that clinical accuracy in the order of I mm may be achieved in US-based surgical navigation.
引用
收藏
页码:1607 / 1623
页数:17
相关论文
共 50 条
  • [31] VALIDITY OF FREEHAND 3-D ULTRASOUND SYSTEM IN MEASUREMENT OF THE 3-D SURFACE SHAPE OF SHOULDER MUSCLES
    Umehara, Jun
    Fukuda, Norio
    Konda, Shoji
    Hirashima, Masaya
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2022, 48 (09): : 1966 - 1976
  • [32] Correction of probe pressure artifacts in freehand 3D ultrasound
    Treece, GM
    Prager, RW
    Gee, AH
    Berman, L
    MEDICAL IMAGE ANALYSIS, 2002, 6 (03) : 199 - 214
  • [33] Phantomless Auto-Calibration and Online Calibration Assessment for a Tracked Freehand 2-D Ultrasound Probe
    Toews, Matthew
    Wells, William M., III
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2018, 37 (01) : 262 - 272
  • [34] Probe Sector Matching for Freehand 3D Ultrasound Reconstruction
    Chen, Xin
    Chen, Houjin
    Peng, Yahui
    Tao, Dan
    SENSORS, 2020, 20 (11)
  • [35] Validation of 3-D freehand ultrasound for the determination of the hip joint centre
    Peters, Alana
    Baker, Richard
    Sangeux, Morgan
    GAIT & POSTURE, 2010, 31 (04) : 530 - 532
  • [36] Median filters used for volume reconstruction in freehand 3-D ultrasound
    Huang, Qinghua
    Zheng, Yongping
    2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2005, : 1826 - 1829
  • [37] Sensorless freehand 3-D ultrasound using regression of the echo intensity
    Prager, RW
    Gee, AH
    Treece, GM
    Cash, CJC
    Berman, LH
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2003, 29 (03): : 437 - 446
  • [38] Efficient Stratified 3-D Scatterer Sampling for Freehand Ultrasound Simulation
    Gaits, Francois
    Mellado, Nicolas
    Bouyjou, Gauthier
    Garcia, Damien
    Basarab, Adrian
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2024, 71 (01) : 127 - 140
  • [39] A robust meshing and calibration approach for sensorless freehand 3D ultrasound
    Rivaz, Hassan
    Boctor, Emad
    Fichtinger, Gabor
    MEDICAL IMAGING 2007: ULTRASONIC IMAGING AND SIGNAL PROCESSING, 2007, 6513
  • [40] An image registration approach to automated calibration for freehand 3D ultrasound
    Blackall, JM
    Rueckert, D
    Maurer, CR
    Penney, GP
    Hill, DLG
    Hawkes, DJ
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2000, 2000, 1935 : 462 - 471