A robust meshing and calibration approach for sensorless freehand 3D ultrasound

被引:3
|
作者
Rivaz, Hassan [1 ]
Boctor, Emad [1 ]
Fichtinger, Gabor [1 ,2 ,3 ]
机构
[1] Johns Hopkins Univ, Dept Comp Sci, Baltimore, MD 21218 USA
[2] Johns Hopkins Univ, Dept Mech Engn, Baltimore, MD USA
[3] Johns Hopkins Univ, Dept Radiol, Baltimore, MD USA
关键词
3D ultrasound; speckle decorrelation; fully developed speckle;
D O I
10.1117/12.712423
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The elevational distance between two ultrasound images can be obtained from the correlation between the two images, leading to sensorless freehand 3D ultrasound systems. Most of these systems rely on the correlation between patches of fully developed speckles (FDS). Previous work(1) has compared different FDS detectors and concluded that the elevational distance measurement limited to the FDS patches obtained by low order moment test yields significantly more accurate results than other FDS detectors. However, small coherent and FDS regions are spread throughout a typical ultrasound image of real tissue. This makes it extremely unlikely to find a regularly shaped (conventionally a rectangle) FDS patch, making it infeasible to estimate elevational distance accurately.(1) In this work, first we propose a simple and fast algorithm which is capable of detecting arbitrarily irregular FDS regions in an ultrasound image. In vitro experiments on beef liver, beef steak and chicken breast indicates that the proposed algorithm generates remarkably more FDS patches than the current methods. Preliminary results show that the FDS patches obtained by this algorithm generate more accurate elevational distance measurement. Second, we propose a new calibration scheme to generate decorrelation curves. At a particular location in the image, conventional methods acquire one decorrelation curve. We create multiple curves, as a function of particular statistical properties of the patch. The results reveal a theoretically expected relation between the decorrelation curve and the statistical properties of the patch. As a result of this calibration based on the patch statistical properties, improvement in the out of plane motion estimation is expected.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Robust and automatic calibration method for 3D freehand ultrasound
    Rousseau, F
    Hellier, P
    Barillot, C
    [J]. MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2003, PT 2, 2003, 2879 : 440 - 448
  • [2] Sensorless reconstruction of freehand 3D ultrasound data
    Housden, R. James
    Gee, Andrew H.
    Treece, Graham M.
    Prager, Richard W.
    [J]. MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2006, PT 2, 2006, 4191 : 356 - 363
  • [3] Confhusius: A robust and fully automatic calibration method for 3D freehand ultrasound
    Rousseau, F
    Hellier, P
    Barillot, C
    [J]. MEDICAL IMAGE ANALYSIS, 2005, 9 (01) : 25 - 38
  • [4] An image registration approach to automated calibration for freehand 3D ultrasound
    Blackall, JM
    Rueckert, D
    Maurer, CR
    Penney, GP
    Hill, DLG
    Hawkes, DJ
    [J]. MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2000, 2000, 1935 : 462 - 471
  • [5] Sensorless reconstruction of unconstrained freehand 3D ultrasound data
    Housden, R. James
    Gee, Andrew H.
    Treece, Graham M.
    Prager, Richard W.
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2007, 33 (03): : 408 - 419
  • [6] Subsample interpolation strategies for sensorless freehand 3D ultrasound
    Housden, R. James
    Gee, Andrew H.
    Treece, Graham M.
    Prager, Richard W.
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2006, 32 (12): : 1897 - 1904
  • [7] Learning for Graph-Based Sensorless Freehand 3D Ultrasound
    Tetrel, Loic
    Chebrek, Hacene
    Laporte, Catherine
    [J]. MACHINE LEARNING IN MEDICAL IMAGING, MLMI 2016, 2016, 10019 : 205 - 212
  • [8] RecON: Online learning for sensorless freehand 3D ultrasound reconstruction
    Luo, Mingyuan
    Yang, Xin
    Wang, Hongzhang
    Dou, Haoran
    Hu, Xindi
    Huang, Yuhao
    Ravikumar, Nishant
    Xu, Songcheng
    Zhang, Yuanji
    Xiong, Yi
    Xue, Wufeng
    Frangi, Alejandro F.
    Ni, Dong
    Sun, Litao
    [J]. MEDICAL IMAGE ANALYSIS, 2023, 87
  • [9] A fully automatic calibration procedure for freehand 3D ultrasound
    Rousseau, F
    Hellier, P
    Barillot, C
    [J]. 2002 IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING, PROCEEDINGS, 2002, : 985 - 988
  • [10] Rapid Calibration of 3D Freehand Ultrasound for Vessel Intervention
    Luan, K.
    Liao, H.
    Ohya, T.
    Wang, J.
    Sakuma, I.
    [J]. 5TH KUALA LUMPUR INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING 2011 (BIOMED 2011), 2011, 35 : 716 - +