Rapid Calibration of 3D Freehand Ultrasound for Vessel Intervention

被引:0
|
作者
Luan, K. [1 ,2 ]
Liao, H. [2 ]
Ohya, T. [2 ]
Wang, J. [3 ]
Sakuma, I. [2 ]
机构
[1] Univ Tokyo, Sch Engn, Bunkyo Ku, 7-3-1 Hongo, Tokyo, Japan
[2] Univ Tokyo, Sch Engn, Tokyo, Japan
[3] Beihang Univ, Inst Robot, Beijing, Peoples R China
关键词
Freehand ultrasound; Calibration; RANSAC; POINT-BASED REGISTRATION; 3-D ULTRASOUND; ARTIFACTS; SYSTEMS; ERROR;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
To create a freehand three-dimensional (3D) ultrasound (US) system for image-guided vessel interventions, a US probe calibration must be performed to build 3D volumes from 2D vessel images. In this paper, a novel calibration method of 3D freehand US is described. It simply images the tip of a tracked needle that could freely move around within the coupling medium while the probe is fixed. The physical coordinates of the tip and the probe location are simultaneously recorded. Image coordinates of the tip are mapped to physical points. A RANSAC algorithm is applied to minimize the error matching image points and physical points. An accuracy evaluation experiment is performed to verify the proposed method. Results show that the needle tip can be accurately located and the RMS calibration error is 1.56mm. A phantom experiment and an in vivo experiment verify the availability of the technique in clinic. That means the present method is applicable to the calibration of a 3D freehand US in vessel interventions.
引用
收藏
页码:716 / +
页数:2
相关论文
共 50 条
  • [1] Rapid, easy and reliable calibration for freehand 3D ultrasound
    Hsu, Po-Wei
    Prager, Richard W.
    Gee, Andrew H.
    Treece, Graham M.
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2006, 32 (06): : 823 - 835
  • [2] Rapid calibration for 3-D freehand ultrasound
    Prager, RW
    Rohling, RN
    Gee, AH
    Berman, L
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 1998, 24 (06): : 855 - 869
  • [3] A fully automatic calibration procedure for freehand 3D ultrasound
    Rousseau, F
    Hellier, P
    Barillot, C
    [J]. 2002 IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING, PROCEEDINGS, 2002, : 985 - 988
  • [4] Robust and automatic calibration method for 3D freehand ultrasound
    Rousseau, F
    Hellier, P
    Barillot, C
    [J]. MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2003, PT 2, 2003, 2879 : 440 - 448
  • [5] Real-time freehand 3D ultrasound calibration
    Hsu, Po-Wei
    Prager, Richard W.
    Graham, Andrew H. Gee
    Treece, Graham M.
    [J]. MEDICAL IMAGING 2007: ULTRASONIC IMAGING AND SIGNAL PROCESSING, 2007, 6513
  • [6] Accurate fiducial location for freehand 3D ultrasound calibration
    Hsu, Po-Wei
    Prager, Richard W.
    Houghton, Neil E.
    Gee, Andrew H.
    Treece, Graham M.
    [J]. MEDICAL IMAGING 2007: ULTRASONIC IMAGING AND SIGNAL PROCESSING, 2007, 6513
  • [7] Real-time freehand 3D ultrasound calibration
    Hsu, Po-Wei
    Prager, Richard W.
    Gee, Andrew H.
    Treece, Graham M.
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2008, 34 (02): : 239 - 251
  • [8] A robust meshing and calibration approach for sensorless freehand 3D ultrasound
    Rivaz, Hassan
    Boctor, Emad
    Fichtinger, Gabor
    [J]. MEDICAL IMAGING 2007: ULTRASONIC IMAGING AND SIGNAL PROCESSING, 2007, 6513
  • [9] Actuator-Assisted Calibration of Freehand 3D Ultrasound System
    Koo, Terry K.
    Silvia, Nathaniel
    [J]. JOURNAL OF HEALTHCARE ENGINEERING, 2018, 2018
  • [10] An image registration approach to automated calibration for freehand 3D ultrasound
    Blackall, JM
    Rueckert, D
    Maurer, CR
    Penney, GP
    Hill, DLG
    Hawkes, DJ
    [J]. MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2000, 2000, 1935 : 462 - 471