Rapid calibration for 3-D freehand ultrasound

被引:313
|
作者
Prager, RW
Rohling, RN
Gee, AH
Berman, L
机构
[1] Univ Cambridge, Dept Engn, Cambridge CB2 1PZ, England
[2] Addenbrookes Hosp, Dept Radiol, Cambridge CB2 2QQ, England
来源
ULTRASOUND IN MEDICINE AND BIOLOGY | 1998年 / 24卷 / 06期
关键词
3-D freehand imaging; calibration; position sensor;
D O I
10.1016/S0301-5629(98)00044-1
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
3-D freehand ultrasound is a new imaging technique that is rapidly finding clinical applications, A position-sensing device is attached to a conventional ultrasound probe so that, as B-scans are acquired, they can be labelled with their relative positions and orientations, This allows a 3-D data set to be constructed from the B-scans, A key requirement of all freehand imaging systems is calibration; that is, determining the position and orientation of the B-scan with respect to the position sensor. This is typically a lengthy and tedious process that may need repeating every time a sensor is mounted on a probe. This paper describes a new calibration technique that takes only a few minutes to perform and produces results that compare favourably (in terms of both accuracy and precision) with previously published alternatives. (C) 1998 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:855 / 869
页数:15
相关论文
共 50 条
  • [1] Probe calibration for freehand 3-D ultrasound
    Lindseth, F
    Tangen, GA
    Lango, T
    Bang, J
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2003, 29 (11): : 1607 - 1623
  • [2] A review of calibration techniques for freehand 3-D ultrasound systems
    Mercier, L
    Lango, T
    Lindseth, F
    Collins, DL
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2005, 31 (04): : 449 - 471
  • [3] A review of calibration techniques for freehand 3-D ultrasound systems
    Mercier, L
    Lango, T
    Lindseth, F
    Collins, LD
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2005, 31 (02): : 143 - 165
  • [4] An efficient calibration method for freehand 3-D ultrasound imaging systems
    Leotta, DF
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2004, 30 (07): : 999 - 1008
  • [5] COMPARISON OF FREEHAND 3-D ULTRASOUND CALIBRATION TECHNIQUES USING A STYLUS
    Hsu, Po-Wei
    Treece, Graham M.
    Prager, Richard W.
    Houghton, Neil E.
    Gee, Andrew H.
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2008, 34 (10): : 1610 - 1621
  • [6] Quantitative evaluation of three calibration methods for 3-D freehand ultrasound
    Rousseau, Francois
    Hellier, Pierre
    Letteboer, Marloes M. J.
    Niessen, Wiro J.
    Barillot, Christian
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2006, 25 (11) : 1492 - 1501
  • [7] Rapid Calibration of 3D Freehand Ultrasound for Vessel Intervention
    Luan, K.
    Liao, H.
    Ohya, T.
    Wang, J.
    Sakuma, I.
    [J]. 5TH KUALA LUMPUR INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING 2011 (BIOMED 2011), 2011, 35 : 716 - +
  • [8] Rapid, easy and reliable calibration for freehand 3D ultrasound
    Hsu, Po-Wei
    Prager, Richard W.
    Gee, Andrew H.
    Treece, Graham M.
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2006, 32 (06): : 823 - 835
  • [9] Beam calibration without a phantom for creating a 3-D freehand ultrasound system
    Muratore, DM
    Galloway, RL
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2001, 27 (11): : 1557 - 1566
  • [10] Bezier Interpolation for 3-D Freehand Ultrasound
    Huang, Qinghua
    Huang, Yanping
    Hu, Wei
    Li, Xuelong
    [J]. IEEE TRANSACTIONS ON HUMAN-MACHINE SYSTEMS, 2015, 45 (03) : 385 - 392