A review of calibration techniques for freehand 3-D ultrasound systems

被引:150
|
作者
Mercier, L
Lango, T
Lindseth, F
Collins, DL
机构
[1] McGill Univ, Montreal Neurol Inst, Montreal, PQ, Canada
[2] SINTEF, Hlth Res, Trondheim, Norway
来源
ULTRASOUND IN MEDICINE AND BIOLOGY | 2005年 / 31卷 / 04期
关键词
ultrasound probe calibration; 3-D ultrasound; freehand acquisition; navigation;
D O I
10.1016/j.ultrasmedbio.2004.11.015
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Three-dimensional (3-D) ultrasound (US) is an emerging new technology with numerous clinical applications. Ultrasound probe calibration is an obligatory step to build 3-D volumes from 2-D images acquired in a freehand US system. The role of calibration is to find the mathematical transformation that converts the 2-D coordinates of pixels in the US image into 3-D coordinates in the frame of reference of a position sensor attached to the US probe. This article is a comprehensive review of what has been published in the field of US probe calibration for 3-D US. The article covers the topics of tracking technologies, US image acquisition, phantom design, speed of sound issues, feature extraction, least-squares minimization, temporal calibration, calibration evaluation techniques and phantom comparisons. The calibration phantoms and methods have also been classified in tables to give a better overview of the existing methods. (E-mail: laurence@bic.mni.mcgill.ca) (c) 2005 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:449 / 471
页数:23
相关论文
共 50 条
  • [1] A review of calibration techniques for freehand 3-D ultrasound systems
    Mercier, L
    Lango, T
    Lindseth, F
    Collins, LD
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2005, 31 (02): : 143 - 165
  • [2] COMPARISON OF FREEHAND 3-D ULTRASOUND CALIBRATION TECHNIQUES USING A STYLUS
    Hsu, Po-Wei
    Treece, Graham M.
    Prager, Richard W.
    Houghton, Neil E.
    Gee, Andrew H.
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2008, 34 (10): : 1610 - 1621
  • [3] Rapid calibration for 3-D freehand ultrasound
    Prager, RW
    Rohling, RN
    Gee, AH
    Berman, L
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 1998, 24 (06): : 855 - 869
  • [4] Probe calibration for freehand 3-D ultrasound
    Lindseth, F
    Tangen, GA
    Lango, T
    Bang, J
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2003, 29 (11): : 1607 - 1623
  • [5] An efficient calibration method for freehand 3-D ultrasound imaging systems
    Leotta, DF
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2004, 30 (07): : 999 - 1008
  • [6] 3-D Calibration algorithm for freehand ultrasound image
    [J]. Peng, Y, 1600, Asian Network for Scientific Information (12):
  • [7] FREEHAND 3-D ULTRASOUND IMAGING: A SYSTEMATIC REVIEW
    Mozaffari, Mohammad Hamed
    Lee, Won-Sook
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2017, 43 (10): : 2099 - 2124
  • [8] Quantitative evaluation of three calibration methods for 3-D freehand ultrasound
    Rousseau, Francois
    Hellier, Pierre
    Letteboer, Marloes M. J.
    Niessen, Wiro J.
    Barillot, Christian
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2006, 25 (11) : 1492 - 1501
  • [9] Beam calibration without a phantom for creating a 3-D freehand ultrasound system
    Muratore, DM
    Galloway, RL
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2001, 27 (11): : 1557 - 1566
  • [10] Bezier Interpolation for 3-D Freehand Ultrasound
    Huang, Qinghua
    Huang, Yanping
    Hu, Wei
    Li, Xuelong
    [J]. IEEE TRANSACTIONS ON HUMAN-MACHINE SYSTEMS, 2015, 45 (03) : 385 - 392