Rapid Calibration of 3D Freehand Ultrasound for Vessel Intervention

被引:0
|
作者
Luan, K. [1 ,2 ]
Liao, H. [2 ]
Ohya, T. [2 ]
Wang, J. [3 ]
Sakuma, I. [2 ]
机构
[1] Univ Tokyo, Sch Engn, Bunkyo Ku, 7-3-1 Hongo, Tokyo, Japan
[2] Univ Tokyo, Sch Engn, Tokyo, Japan
[3] Beihang Univ, Inst Robot, Beijing, Peoples R China
关键词
Freehand ultrasound; Calibration; RANSAC; POINT-BASED REGISTRATION; 3-D ULTRASOUND; ARTIFACTS; SYSTEMS; ERROR;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
To create a freehand three-dimensional (3D) ultrasound (US) system for image-guided vessel interventions, a US probe calibration must be performed to build 3D volumes from 2D vessel images. In this paper, a novel calibration method of 3D freehand US is described. It simply images the tip of a tracked needle that could freely move around within the coupling medium while the probe is fixed. The physical coordinates of the tip and the probe location are simultaneously recorded. Image coordinates of the tip are mapped to physical points. A RANSAC algorithm is applied to minimize the error matching image points and physical points. An accuracy evaluation experiment is performed to verify the proposed method. Results show that the needle tip can be accurately located and the RMS calibration error is 1.56mm. A phantom experiment and an in vivo experiment verify the availability of the technique in clinic. That means the present method is applicable to the calibration of a 3D freehand US in vessel interventions.
引用
收藏
页码:716 / +
页数:2
相关论文
共 50 条
  • [31] Trackerless 3D Freehand Ultrasound Reconstruction: A Review
    Adriaans, Chrissy A.
    Wijkhuizen, Mark
    van Karnenbeek, Lennard M.
    Geldof, Freija
    Dashtbozorg, Behdad
    [J]. APPLIED SCIENCES-BASEL, 2024, 14 (17):
  • [32] A review of calibration techniques for freehand 3-D ultrasound systems
    Mercier, L
    Lango, T
    Lindseth, F
    Collins, DL
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2005, 31 (04): : 449 - 471
  • [33] Development of a 3D Reconstruction of Blood Vessel by Positional Calibration of Ultrasound Probe
    Sugano, Yuki
    Onogi, Shinya
    Bossard, Antoine
    Mochizuki, Takashi
    Masuda, Kohji
    [J]. 5TH BIOMEDICAL ENGINEERING INTERNATIONAL CONFERENCE (BMEICON 2012), 2012,
  • [34] Development of a 3D Reconstruction of Blood Vessel by Positional Calibration of Ultrasound Probe
    Sugano, Yuki
    Onogi, Shinya
    Bossard, Antoine
    Mochizuki, Takashi
    Masuda, Kohji
    [J]. 5TH BIOMEDICAL ENGINEERING INTERNATIONAL CONFERENCE (BMEICON 2012), 2012, : 99 - 100
  • [35] A review of calibration techniques for freehand 3-D ultrasound systems
    Mercier, L
    Lango, T
    Lindseth, F
    Collins, LD
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2005, 31 (02): : 143 - 165
  • [36] Freehand 3D Ultrasound Calibration based on two-layer Z-fiducial phantom
    Wang, Xiaoyu
    Wu, Dongmei
    Du, Zhijiang
    [J]. EQUIPMENT MANUFACTURING TECHNOLOGY AND AUTOMATION, PTS 1-3, 2011, 317-319 : 638 - 642
  • [37] Subsample interpolation strategies for sensorless freehand 3D ultrasound
    Housden, R. James
    Gee, Andrew H.
    Treece, Graham M.
    Prager, Richard W.
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2006, 32 (12): : 1897 - 1904
  • [38] Real-time tools for freehand 3D ultrasound
    Prager, R
    Gee, A
    Berman, L
    [J]. MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI'98, 1998, 1496 : 1016 - 1023
  • [39] Deep Motion Network for Freehand 3D Ultrasound Reconstruction
    Luo, Mingyuan
    Yang, Xin
    Wang, Hongzhang
    Du, Liwei
    Ni, Dong
    [J]. MEDICAL IMAGE COMPUTING AND COMPUTER ASSISTED INTERVENTION, MICCAI 2022, PT IV, 2022, 13434 : 290 - 299
  • [40] Adaptive Kernel Regression for Freehand 3D Ultrasound Reconstruction
    Alshalalfah, Abdel-Latif
    Daoud, Mohammad I.
    Al-Najar, Mahasen
    [J]. MEDICAL IMAGING 2017: ULTRASONIC IMAGING AND TOMOGRAPHY, 2017, 10139