This paper describes a novel method for calibration of freehand three-dimensional (3D) ultrasound. A position sensor is mounted on a conventional ultrasound probe, thus the set of B-scans can be localized in 3D, and can be compounded into a volume. The calibration process aims at determining the transformation (translations, rotations, scaling) between the coordinates system of images and the coordinate system of the localization system. In our study, the phantom used to calibrate the 3D ultrasound system is a plane. It provides in each image a strong, straight line. The calibration process is based on the set of lines in 2D images forming a plane in 3D. Points of interest are extracted from the ultrasound sequence. The eight parameters of the transformation are determined with an iterative algorithm which is based on the principle that correct registration between the plane and the points of interest provides correct calibration. Validation of this method has been performed on synthetic sequences. This calibration method is shown to be easy to perform, completely automatic and fast enough for clinical use.
引用
收藏
页码:985 / 988
页数:4
相关论文
共 50 条
  • [1] Confhusius: A robust and fully automatic calibration method for 3D freehand ultrasound
    Rousseau, F
    Hellier, P
    Barillot, C
    MEDICAL IMAGE ANALYSIS, 2005, 9 (01) : 25 - 38
  • [2] Robust and automatic calibration method for 3D freehand ultrasound
    Rousseau, F
    Hellier, P
    Barillot, C
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2003, PT 2, 2003, 2879 : 440 - 448
  • [3] Rapid Calibration of 3D Freehand Ultrasound for Vessel Intervention
    Luan, K.
    Liao, H.
    Ohya, T.
    Wang, J.
    Sakuma, I.
    5TH KUALA LUMPUR INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING 2011 (BIOMED 2011), 2011, 35 : 716 - +
  • [4] Rapid, easy and reliable calibration for freehand 3D ultrasound
    Hsu, Po-Wei
    Prager, Richard W.
    Gee, Andrew H.
    Treece, Graham M.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2006, 32 (06): : 823 - 835
  • [5] Real-time freehand 3D ultrasound calibration
    Hsu, Po-Wei
    Prager, Richard W.
    Graham, Andrew H. Gee
    Treece, Graham M.
    MEDICAL IMAGING 2007: ULTRASONIC IMAGING AND SIGNAL PROCESSING, 2007, 6513
  • [6] Accurate fiducial location for freehand 3D ultrasound calibration
    Hsu, Po-Wei
    Prager, Richard W.
    Houghton, Neil E.
    Gee, Andrew H.
    Treece, Graham M.
    MEDICAL IMAGING 2007: ULTRASONIC IMAGING AND SIGNAL PROCESSING, 2007, 6513
  • [7] Real-time freehand 3D ultrasound calibration
    Hsu, Po-Wei
    Prager, Richard W.
    Gee, Andrew H.
    Treece, Graham M.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2008, 34 (02): : 239 - 251
  • [8] A robust meshing and calibration approach for sensorless freehand 3D ultrasound
    Rivaz, Hassan
    Boctor, Emad
    Fichtinger, Gabor
    MEDICAL IMAGING 2007: ULTRASONIC IMAGING AND SIGNAL PROCESSING, 2007, 6513
  • [9] Actuator-Assisted Calibration of Freehand 3D Ultrasound System
    Koo, Terry K.
    Silvia, Nathaniel
    JOURNAL OF HEALTHCARE ENGINEERING, 2018, 2018
  • [10] An image registration approach to automated calibration for freehand 3D ultrasound
    Blackall, JM
    Rueckert, D
    Maurer, CR
    Penney, GP
    Hill, DLG
    Hawkes, DJ
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2000, 2000, 1935 : 462 - 471