Speckle classification for sensorless freehand 3-D ultrasound

被引:24
|
作者
Hassenpflug, P [1 ]
Prager, RW [1 ]
Treece, GM [1 ]
Gee, AH [1 ]
机构
[1] Univ Cambridge, Dept Engn, Cambridge CB2 1PZ, England
来源
ULTRASOUND IN MEDICINE AND BIOLOGY | 2005年 / 31卷 / 11期
基金
英国工程与自然科学研究理事会;
关键词
speckle decorrelation; speckle detection; freehand three-dimensional ultrasound;
D O I
10.1016/j.ultrasmedbio.2005.07.007
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Despite being a valuable tool for volume measurement and the analysis of complex geometry, the need for an external position sensor is holding up the clinical exploitation of freehand 3-D ultrasound. Some sensorless systems have been developed, using speckle decorrelation for out-of-plane distance estimation, but their accuracy is still not as good as that of sensor-based systems. Here, we examine the widely held belief that accuracy can be improved by limiting the distance measurements to patches of ultrasound data containing fully developed speckle. Without speckle detection, we observe that scan separation is systematically underestimated by 33.1% in biological tissue. We describe a number of speckle detectors and show that they reduce the underestimate to about 25%. We conclude that speckle classification can improve the quality of distance estimation, but not sufficiently to achieve accurate, metric reconstruction of the insonified volume. (E-mail: ph305@eng.cam.ac.uk) (C) 2005 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:1499 / 1508
页数:10
相关论文
共 50 条
  • [1] Sensorless freehand 3-D ultrasound using regression of the echo intensity
    Prager, RW
    Gee, AH
    Treece, GM
    Cash, CJC
    Berman, LH
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2003, 29 (03): : 437 - 446
  • [2] Sensorless freehand 3D ultrasound in real tissue: Speckle decorrelation without fully developed speckle
    Gee, AH
    Housden, RJ
    Hassenpflug, P
    Treece, GM
    Prager, RW
    [J]. MEDICAL IMAGE ANALYSIS, 2006, 10 (02) : 137 - 149
  • [3] Rapid calibration for 3-D freehand ultrasound
    Prager, RW
    Rohling, RN
    Gee, AH
    Berman, L
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 1998, 24 (06): : 855 - 869
  • [4] Bezier Interpolation for 3-D Freehand Ultrasound
    Huang, Qinghua
    Huang, Yanping
    Hu, Wei
    Li, Xuelong
    [J]. IEEE TRANSACTIONS ON HUMAN-MACHINE SYSTEMS, 2015, 45 (03) : 385 - 392
  • [5] Freehand ultrasound elastography with a 3-D probe
    Treece, Graham M.
    Lindop, Joel E.
    Gee, Andrew H.
    Prager, Richard W.
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2008, 34 (03): : 463 - 474
  • [6] Sensorless reconstruction of freehand 3D ultrasound data
    Housden, R. James
    Gee, Andrew H.
    Treece, Graham M.
    Prager, Richard W.
    [J]. MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2006, PT 2, 2006, 4191 : 356 - 363
  • [7] Probe calibration for freehand 3-D ultrasound
    Lindseth, F
    Tangen, GA
    Lango, T
    Bang, J
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2003, 29 (11): : 1607 - 1623
  • [8] Sensorless reconstruction of unconstrained freehand 3D ultrasound data
    Housden, R. James
    Gee, Andrew H.
    Treece, Graham M.
    Prager, Richard W.
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2007, 33 (03): : 408 - 419
  • [9] Subsample interpolation strategies for sensorless freehand 3D ultrasound
    Housden, R. James
    Gee, Andrew H.
    Treece, Graham M.
    Prager, Richard W.
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2006, 32 (12): : 1897 - 1904
  • [10] 3-D Calibration algorithm for freehand ultrasound image
    [J]. Peng, Y., 1600, Asian Network for Scientific Information (12):