Volume measurement in sequential freehand 3-D ultrasound

被引:0
|
作者
Treece, G
Prager, R
Gee, A
Berman, L
机构
[1] Univ Cambridge, Dept Engn, Cambridge CB2 1PZ, England
[2] Univ Cambridge, Addenbrookes Hosp, Dept Radiol, Cambridge CB2 2QQ, England
关键词
D O I
暂无
中图分类号
TP301 [理论、方法];
学科分类号
081202 ;
摘要
It has previously been demonstrated that using 3-D rather than 2-D ultrasound can increase the accuracy of volume measurements. Unfortunately, the time required to produce them is also increased. While freehand 3-D ultrasound allows complete freedom of movement during scanning. the resulting B-scans are generally resampled onto a low resolution, regular voxel array before subsequent processing - increasing the time even further. In contrast, sequential freehand 3-D ultrasound does not require a voxel array, and hence both the data resolution and the processing times are improved. Such a system is presented here, incorporating three novel algorithms, each operating directly on non-parallel B-scans. Volume is measured using Cubic planimetry, which requires fewer planes than step-section planimetry for a given accuracy. Maximal disc guided interpolation can be used to interpolate non-parallel cross-sections. Regularised marching tetrahedra can then be used to provide a regular triangulation of the zero iso-surface of the interpolated data. The first of these algorithms is presented in detail in this paper.
引用
收藏
页码:70 / 83
页数:14
相关论文
共 50 条
  • [1] Median filters used for volume reconstruction in freehand 3-D ultrasound
    Huang, Qinghua
    Zheng, Yongping
    [J]. 2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2005, : 1826 - 1829
  • [2] 3D object volume measurement using freehand ultrasound
    Bogush, AL
    Tuzikov, AV
    [J]. IMAGE ANALYSIS, PROCEEDINGS, 2005, 3540 : 1066 - 1075
  • [3] VALIDITY OF FREEHAND 3-D ULTRASOUND SYSTEM IN MEASUREMENT OF THE 3-D SURFACE SHAPE OF SHOULDER MUSCLES
    Umehara, Jun
    Fukuda, Norio
    Konda, Shoji
    Hirashima, Masaya
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2022, 48 (09): : 1966 - 1976
  • [4] Rapid calibration for 3-D freehand ultrasound
    Prager, RW
    Rohling, RN
    Gee, AH
    Berman, L
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 1998, 24 (06): : 855 - 869
  • [5] Bezier Interpolation for 3-D Freehand Ultrasound
    Huang, Qinghua
    Huang, Yanping
    Hu, Wei
    Li, Xuelong
    [J]. IEEE TRANSACTIONS ON HUMAN-MACHINE SYSTEMS, 2015, 45 (03) : 385 - 392
  • [6] Freehand ultrasound elastography with a 3-D probe
    Treece, Graham M.
    Lindop, Joel E.
    Gee, Andrew H.
    Prager, Richard W.
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2008, 34 (03): : 463 - 474
  • [7] Probe calibration for freehand 3-D ultrasound
    Lindseth, F
    Tangen, GA
    Lango, T
    Bang, J
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2003, 29 (11): : 1607 - 1623
  • [8] 3-D Calibration algorithm for freehand ultrasound image
    [J]. Peng, Y., 1600, Asian Network for Scientific Information (12):
  • [9] FREEHAND 3-D ULTRASOUND IMAGING: A SYSTEMATIC REVIEW
    Mozaffari, Mohammad Hamed
    Lee, Won-Sook
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2017, 43 (10): : 2099 - 2124
  • [10] Speckle classification for sensorless freehand 3-D ultrasound
    Hassenpflug, P
    Prager, RW
    Treece, GM
    Gee, AH
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2005, 31 (11): : 1499 - 1508