Volume measurement in sequential freehand 3-D ultrasound

被引:0
|
作者
Treece, G
Prager, R
Gee, A
Berman, L
机构
[1] Univ Cambridge, Dept Engn, Cambridge CB2 1PZ, England
[2] Univ Cambridge, Addenbrookes Hosp, Dept Radiol, Cambridge CB2 2QQ, England
关键词
D O I
暂无
中图分类号
TP301 [理论、方法];
学科分类号
081202 ;
摘要
It has previously been demonstrated that using 3-D rather than 2-D ultrasound can increase the accuracy of volume measurements. Unfortunately, the time required to produce them is also increased. While freehand 3-D ultrasound allows complete freedom of movement during scanning. the resulting B-scans are generally resampled onto a low resolution, regular voxel array before subsequent processing - increasing the time even further. In contrast, sequential freehand 3-D ultrasound does not require a voxel array, and hence both the data resolution and the processing times are improved. Such a system is presented here, incorporating three novel algorithms, each operating directly on non-parallel B-scans. Volume is measured using Cubic planimetry, which requires fewer planes than step-section planimetry for a given accuracy. Maximal disc guided interpolation can be used to interpolate non-parallel cross-sections. Regularised marching tetrahedra can then be used to provide a regular triangulation of the zero iso-surface of the interpolated data. The first of these algorithms is presented in detail in this paper.
引用
收藏
页码:70 / 83
页数:14
相关论文
共 50 条
  • [41] 3-D measurement of body tissues based on ultrasound images with 3-D spatial information
    Huang, QH
    Zheng, YP
    Li, R
    Lu, MH
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2005, 31 (12): : 1607 - 1615
  • [42] ABDOMINAL AORTIC ANEURYSM IMAGING WITH 3-D ULTRASOUND: 3-D-BASED MAXIMUM DIAMETER MEASUREMENT AND VOLUME QUANTIFICATION
    Long, A.
    Rouet, L.
    Debreuve, A.
    Ardon, R.
    Barbe, C.
    Becquemin, J. P.
    Allaire, E.
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2013, 39 (08): : 1325 - 1336
  • [43] The assessment of normal fetal brain volume by 3-D ultrasound
    Chang, CH
    Yu, CH
    Chang, FM
    Ko, HC
    Chen, HY
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2003, 29 (09): : 1267 - 1272
  • [44] Preprocessing and efficient volume rendering of 3-D ultrasound image
    [J]. Kim, CheolAn, 1600, IEICE of Japan, Japan (E83-D):
  • [45] A new scanning approach for limb extremities using a water bag in freehand 3-D ultrasound
    Huang, QH
    Zheng, YP
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2005, 31 (04): : 575 - 583
  • [46] 3-D FREEHAND ULTRASOUND CALIBRATION USING A TISSUE-MIMICKING PHANTOM WITH PARALLEL WIRES
    Marcadent, Sandra
    Heches, Johann
    Favre, Julien
    Desseauve, David
    Thiran, Jean-Philippe
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2023, 49 (01): : 165 - 177
  • [47] A Methodology for Non-Invasive 3-D Surveillance of Arteriovenous Fistulae Using Freehand Ultrasound
    Colley, Eamonn
    Carroll, John
    Thomas, Shannon
    Varcoe, Ramon L.
    Simmons, Anne
    Barber, Tracie
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2018, 65 (08) : 1885 - 1891
  • [48] Automatic Diagnosis of Carotid Atherosclerosis Using a Portable Freehand 3-D Ultrasound Imaging System
    Li, Jiawen
    Huang, Yunqian
    Song, Sheng
    Chen, Hongbo
    Shi, Junni
    Xu, Duo
    Zhang, Haibin
    Chen, Man
    Zheng, Rui
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2024, 71 (02) : 266 - 279
  • [49] Preprocessing and efficient volume rendering of 3-D ultrasound image
    Kim, C
    Park, H
    [J]. IEICE TRANSACTIONS ON INFORMATION AND SYSTEMS, 2000, E83D (02) : 259 - 264
  • [50] Reliability of 3-D ultrasound of cervical lymph node volume
    Ying, Michael
    Pang, Shuk-Fan
    Sin, Man-Hong
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2006, 32 (07): : 995 - 1001