3-D measurement of body tissues based on ultrasound images with 3-D spatial information

被引:12
|
作者
Huang, QH
Zheng, YP [1 ]
Li, R
Lu, MH
机构
[1] Hong Kong Polytech Univ, Dept Hlth Technol & Informat, Kowloon, Hong Kong, Peoples R China
[2] St Pauls Hosp, Dept Diagnost Radiol, Hong Kong, Hong Kong, Peoples R China
来源
ULTRASOUND IN MEDICINE AND BIOLOGY | 2005年 / 31卷 / 12期
关键词
3-D ultrasound; ultrasound; MRI; 3-D measurement; musculoskeletal body parts;
D O I
10.1016/j.ultrasmedbio.2005.08.004
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
In this study, we developed a new method to perform 3-D measurements between the recorded B-scans using the corresponding spatial location and orientation of each B-scan, without the need to create a 3-D volume. A portable ultrasound (US) scanner and an electromagnetic spatial locator attached to the US probe were used. During data collection, the US probe was moved over the region-of-interest. A small number of B-scans containing interesting anatomical information were captured from different body parts and displayed in a 3-D space with their corresponding locations recorded by the spatial locator. In the B-scan planes, the distance between any two points, as well as the angle between any two lines, could be calculated. In validation experiments, three distances and three angles of a custom-designed phantom were measured using this method. In comparison with the results measured by a micrometer, the mean error of distance measurement was -0.8 +/- 1.7 mm (-2.3 +/- 3.6%) and that of angle measurement was -0.3 +/- 2.9 degrees (-0.1 +/- 4.1%). The lengths of the first metatarsals and the angles between the first metatarsals and the middle part of the tibias of three subjects were measured in vivo using magnetic resonance imaging (MRI) and the US method by two operators before and after MRI scanning. The overall percentage differences of the length and angle measurements were 0.8 +/- 2.2% and 2.5 +/- 3.6%, respectively. The results showed that this US method had good repeatability and reproducibility (interclass correlation coefficient values > 0.75). We expect that this new method could potentially provide a quick and effective approach for the 3-D measurement of soft tissues and bones in the musculoskeletal system. (c) 2005 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:1607 / 1615
页数:9
相关论文
共 50 条
  • [1] Spatial compounding of 3-D ultrasound images
    Rohling, R
    Gee, A
    Berman, L
    [J]. INFORMATION PROCESSING IN MEDICAL IMAGING, 1997, 1230 : 519 - 524
  • [2] Automatic registration of 3-D ultrasound images
    Rohling, RN
    Gee, AH
    Berman, L
    [J]. SIXTH INTERNATIONAL CONFERENCE ON COMPUTER VISION, 1998, : 298 - 303
  • [3] Automatic registration of 3-D ultrasound images
    Rohling, RN
    Gee, AH
    Berman, L
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 1998, 24 (06): : 841 - 854
  • [4] A 3-D CA-based edge operator for 3-D images
    Wongthanavasu, S
    Lursinsap, C
    [J]. ICIP: 2004 INTERNATIONAL CONFERENCE ON IMAGE PROCESSING, VOLS 1- 5, 2004, : 235 - 238
  • [5] 3-D ultrasound
    Staedter, T
    [J]. TECHNOLOGY REVIEW, 2003, 106 (06): : 73 - 73
  • [6] The 3-D rigid body line displacements and 3-D rigid body angle displacements measurement
    Zhou, J
    Zhao, H
    Chen, WY
    Tian, F
    Tan, YS
    [J]. AUTOMATED OPTICAL INSPECTION FOR INDUSTRY, 1996, 2899 : 667 - 674
  • [7] A 3-D Bilateral Filter for Speckle Reduction in 3-D Ultrasound Images for Cattle Follicle Segmentation
    Tang, Jinshan
    Guo, Shengwen
    [J]. PROCEEDINGS 2012 IEEE INTERNATIONAL CONFERENCE ON SYSTEMS, MAN, AND CYBERNETICS (SMC), 2012, : 2485 - 2488
  • [8] 3-D or not 3-D
    Adam Powell
    [J]. JOM, 2002, 54 : 22 - 24
  • [9] 3-D OR NOT 3-D
    SMITH, CW
    [J]. NEW SCIENTIST, 1984, 102 (1407) : 40 - 44
  • [10] 3-D OR NOT 3-D
    KERBEL, M
    [J]. FILM COMMENT, 1980, 16 (06) : 11 - 20